.\" (C)Copyright 1999-2003 Marvell(R) -- linux@syskonnect.de
.\" sk98lin.4 1.1 2003/12/17 10:03:18
.\" This manpage can be viewed using `groff -Tascii -man sk98lin.4 | less`
.\"
.\" This is free documentation; you can redistribute it and/or
.\" modify it under the terms of the GNU General Public License as
.\" published by the Free Software Foundation; either version 2 of
.\" the License, or (at your option) any later version.
.\"
.\" The GNU General Public License's references to "object code"
.\" and "executables" are to be interpreted as the output of any
.\" document formatting or typesetting system, including
.\" intermediate and printed output.
.\"
.\" This manual is distributed in the hope that it will be useful,
.\" but WITHOUT ANY WARRANTY; without even the implied warranty of
.\" MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
.\" GNU General Public License for more details.
.\"
.\" You should have received a copy of the GNU General Public
.\" License along with this manual; if not, write to the Free
.\" Software Foundation, Inc., 59 Temple Place, Suite 330, Boston, MA 02111,
.\" USA.
.\"
2007-11-19 08:13:45 +00:00
.TH SK98LIN 4 2007-11-25 "Linux" "Linux Programmer's Manual"
2004-11-03 13:51:07 +00:00
.SH NAME
sk98lin \- Marvell/SysKonnect Gigabit Ethernet driver v6.21
.SH SYNOPSIS
.B insmod sk98lin.o
.RB [ Speed_A=\c
.IR i,j,... ]
.RB [ Speed_B=\c
.IR i,j,... ]
.RB [ AutoNeg_A=\c
.IR i,j,... ]
.RB [ AutoNeg_B=\c
.IR i,j,... ]
.RB [ DupCap_A=\c
.IR i,j,... ]
.RB [ DupCap_B=\c
.IR i,j,... ]
.RB [ FlowCtrl_A=\c
.IR i,j,... ]
.RB [ FlowCtrl_B=\c
.IR i,j,... ]
.RB [ Role_A=\c
.IR i,j,... ]
.RB [ Role_B=\c
.IR i,j,... ]
.RB [ ConType=\c
.IR i,j,... ]
.RB [ Moderation=\c
.IR i,j,... ]
.RB [ IntsPerSec=\c
.IR i,j,... ]
.RB [ PrefPort=\c
.IR i,j,... ]
.RB [ RlmtMode=\c
.IR i,j,... ]
.SH DESCRIPTION
.B sk98lin
is the Gigabit Ethernet driver for
Marvell and SysKonnect network adapter cards.
It supports SysKonnect SK-98xx/SK-95xx
compliant Gigabit Ethernet Adapter and
2006-12-27 03:54:41 +00:00
any Yukon compliant chipset.
2004-11-03 13:51:07 +00:00
When loading the driver using insmod,
parameters for the network adapter cards
might be stated as a sequence of comma separated commands.
If for instance two network adapters are installed and AutoNegotiation on
Port A of the first adapter should be ON,
2006-12-27 03:54:41 +00:00
but on the Port A of the second adapter switched OFF, one must enter:
2004-11-03 13:51:07 +00:00
insmod sk98lin.o AutoNeg_A=On,Off
2005-10-24 09:14:25 +00:00
After
.B sk98lin
is bound to one or more adapter cards and the
2007-09-20 16:26:31 +00:00
.I /proc
filesystem is mounted on your system, a dedicated statistics file
2006-12-27 03:54:41 +00:00
will be created in folder
2007-09-20 16:26:31 +00:00
.I /proc/net/sk98lin
for all ports of the installed network adapter cards.
2006-12-27 03:54:41 +00:00
Those files are named
2007-09-20 16:26:31 +00:00
.I eth[x]
2005-10-24 09:14:25 +00:00
whereas
2007-09-20 16:26:31 +00:00
.I x
is the number of the interface that has been assigned to a
2006-12-27 03:54:41 +00:00
dedicated port by the system.
2004-11-03 13:51:07 +00:00
If loading is finished, any desired IP address can be
2006-12-27 03:54:41 +00:00
assigned to the respective
2007-09-20 16:26:31 +00:00
.I eth[x]
2005-10-24 09:14:25 +00:00
interface using the
2004-11-03 13:51:07 +00:00
.BR ifconfig (8)
command.
This causes the adapter to connect to the Ethernet and to display a status
message on the console saying "ethx: network connection up using port y"
2006-12-27 03:54:41 +00:00
followed by the configured or detected connection parameters.
2004-11-03 13:51:07 +00:00
2005-10-24 09:14:25 +00:00
The
.B sk98lin
also supports large frames (also called jumbo frames).
Using jumbo frames can improve throughput tremendously when
transferring large amounts of data.
To enable large frames, the MTU (maximum transfer unit) size
for an interface is to be set to a high value.
The default MTU size is 1500 and can be changed up to 9000 (bytes).
Setting the MTU size can be done when assigning the IP address
2006-12-27 03:54:41 +00:00
to the interface or later by using the
2004-11-03 13:51:07 +00:00
.BR ifconfig (8)
command with the mtu parameter.
If for instance eth0 needs an IP
address and a large frame MTU size,
2006-12-27 03:54:41 +00:00
the following two commands might be used:
2004-11-03 13:51:07 +00:00
ifconfig eth0 10.1.1.1
ifconfig eth0 mtu 9000
Those two commands might even be combined into one:
ifconfig eth0 10.1.1.1 mtu 9000
Note that large frames can only be used if your network infrastructure
allows to do so.
This means, that any switch being used in your Ethernet must
also support large frames.
Quite some switches support large frames,
2006-12-27 03:54:41 +00:00
but need to be configured to do so.
Most of the times, their default setting is to support only
standard frames with an MTU size of 1500 (bytes).
In addition to the switches inside the network,
all network adapters that are to be used must also be
enabled regarding jumbo frames.
2006-12-27 03:54:41 +00:00
If an adapter is not set to receive large frames it will simply drop them.
2004-11-03 13:51:07 +00:00
Switching back to the standard Ethernet frame size can be done by using the
.BR ifconfig (8)
command again:
ifconfig eth0 mtu 1500
The Marvell/SysKonnect Gigabit Ethernet driver for Linux is able to
support VLAN and Link Aggregation according to
IEEE standards 802.1, 802.1q, and 802.3ad.
2006-12-27 03:54:41 +00:00
Those features are only available after installation of open source modules
which can be found on the Internet:
2004-11-03 13:51:07 +00:00
.IR VLAN \c
: http://www.candelatech.com/~greear/vlan.html
.br
2007-09-20 16:26:31 +00:00
.I Link
2004-11-03 13:51:07 +00:00
.IR Aggregation \c
: http://www.st.rim.or.jp/~yumo
.br
Note that Marvell/SysKonnect does not offer any support for these
open source modules and does not take the responsibility for any
2006-12-27 03:54:41 +00:00
kind of failures or problems arising when using these modules.
2007-06-15 19:55:07 +00:00
.SS Parameters
2004-11-03 13:51:07 +00:00
.TP
.BI Speed_A= i,j,...
This parameter is used to set the speed capabilities of port A of an
adapter card.
It is only valid for Yukon copper adapters.
2006-12-27 03:54:41 +00:00
Possible values are:
2005-10-24 08:55:52 +00:00
.IR 10 ,
.IR 100 ,
2007-09-20 16:26:31 +00:00
.I 1000
2004-11-03 13:51:07 +00:00
or
2007-09-20 16:26:31 +00:00
.I Auto
2005-10-24 09:14:25 +00:00
whereas
2007-09-20 16:26:31 +00:00
.I Auto
is the default.
Usually, the speed is negotiated between the two ports
during link establishment.
If this fails,
a port can be forced to a specific setting with this parameter.
2004-11-03 13:51:07 +00:00
.TP
.BI Speed_B= i,j,...
This parameter is used to set the speed capabilities of port B of
an adapter card.
It is only valid for Yukon copper adapters.
2006-12-27 03:54:41 +00:00
Possible values are:
2005-10-24 08:55:52 +00:00
.IR 10 ,
.IR 100 ,
2007-09-20 16:26:31 +00:00
.I 1000
2004-11-03 13:51:07 +00:00
or
2007-09-20 16:26:31 +00:00
.I Auto
2005-10-24 09:14:25 +00:00
whereas
2007-09-20 16:26:31 +00:00
.I Auto
is the default.
Usually, the speed is negotiated between the two ports during link
establishment.
If this fails,
a port can be forced to a specific setting with this parameter.
2004-11-03 13:51:07 +00:00
.TP
.BI AutoNeg_A= i,j,...
Enables or disables the use of autonegotiation of port A of an adapter card.
2006-12-27 03:54:41 +00:00
Possible values are:
2005-10-24 08:55:52 +00:00
.IR On ,
2007-09-20 16:26:31 +00:00
.I Off
2004-11-03 13:51:07 +00:00
or
2007-09-20 16:26:31 +00:00
.I Sense
2004-11-03 13:51:07 +00:00
whereas
2007-09-20 16:26:31 +00:00
.I On
is the default.
The
2007-09-20 16:26:31 +00:00
.I Sense
mode automatically detects whether the link partner supports
2006-12-27 03:54:41 +00:00
auto-negotiation or not.
2004-11-03 13:51:07 +00:00
.TP
.BI AutoNeg_B= i,j,...
Enables or disables the use of autonegotiation of port B of an adapter card.
2006-12-27 03:54:41 +00:00
Possible values are:
2005-10-24 08:55:52 +00:00
.IR On ,
2007-09-20 16:26:31 +00:00
.I Off
2004-11-03 13:51:07 +00:00
or
2007-09-20 16:26:31 +00:00
.I Sense
2004-11-03 13:51:07 +00:00
whereas
2007-09-20 16:26:31 +00:00
.I On
is the default.
The
2007-09-20 16:26:31 +00:00
.I Sense
mode automatically detects whether the link partner supports
2006-12-27 03:54:41 +00:00
auto-negotiation or not.
2004-11-03 13:51:07 +00:00
.TP
.BI DupCap_A= i,j,...
This parameter indicates the duplex mode to be used for port A
of an adapter card.
2006-12-27 03:54:41 +00:00
Possible values are:
2005-10-24 08:55:52 +00:00
.IR Half ,
2007-09-20 16:26:31 +00:00
.I Full
2004-11-03 13:51:07 +00:00
or
2007-09-20 16:26:31 +00:00
.I Both
2004-11-03 13:51:07 +00:00
whereas
2007-09-20 16:26:31 +00:00
.I Both
2005-10-24 09:14:25 +00:00
is the default.
This parameter is only relevant if AutoNeg_A of port A is not set to
2005-07-19 15:36:19 +00:00
.IR Sense .
2005-10-24 09:14:25 +00:00
If AutoNeg_A is set to
.IR On ,
2005-10-24 08:55:52 +00:00
all three values of DupCap_A (
2005-10-24 09:14:25 +00:00
.IR Half ,
2007-09-20 16:26:31 +00:00
.I Full
2005-10-24 09:14:25 +00:00
or
.IR Both )
might be stated.
If AutoNeg_A is set to
2005-10-24 09:14:25 +00:00
.IR Off ,
only DupCap_A values
2007-09-20 16:26:31 +00:00
.I Full
2005-10-24 09:14:25 +00:00
and
2007-09-20 16:26:31 +00:00
.I Half
are allowed.
This DupCap_A parameter is useful if your link partner does not
2006-12-27 03:54:41 +00:00
support all possible duplex combinations.
2004-11-03 13:51:07 +00:00
.TP
.BI DupCap_B= i,j,...
This parameter indicates the duplex mode to be used for port B
of an adapter card.
2006-12-27 03:54:41 +00:00
Possible values are:
2005-10-24 08:55:52 +00:00
.IR Half ,
2007-09-20 16:26:31 +00:00
.I Full
2004-11-03 13:51:07 +00:00
or
2007-09-20 16:26:31 +00:00
.I Both
2004-11-03 13:51:07 +00:00
whereas
2007-09-20 16:26:31 +00:00
.I Both
is the default.
2006-12-27 03:54:41 +00:00
This parameter is only relevant if AutoNeg_B of port B is not set to
2005-07-19 15:36:19 +00:00
.IR Sense .
2004-11-03 13:51:07 +00:00
If AutoNeg_B is set to
2005-10-24 09:14:25 +00:00
.IR On ,
2005-10-24 08:55:52 +00:00
all three values of DupCap_B (
.IR Half ,
2007-09-20 16:26:31 +00:00
.I Full
2004-11-03 13:51:07 +00:00
or
2005-10-24 13:01:46 +00:00
.IR Both )
might be stated.
If AutoNeg_B is set to
2005-10-24 09:14:25 +00:00
.IR Off ,
2005-10-24 08:55:52 +00:00
only DupCap_B values
2007-09-20 16:26:31 +00:00
.I Full
2004-11-03 13:51:07 +00:00
and
2007-09-20 16:26:31 +00:00
.I Half
are allowed.
This DupCap_B parameter is useful if your link partner does not
2006-12-27 03:54:41 +00:00
support all possible duplex combinations.
2004-11-03 13:51:07 +00:00
.TP
.BI FlowCtrl_A= i,j,...
This parameter can be used to set the flow control capabilities the
port reports during auto-negotiation.
2006-12-27 03:54:41 +00:00
Possible values are:
2005-10-24 08:55:52 +00:00
.IR Sym ,
.IR SymOrRem ,
2007-09-20 16:26:31 +00:00
.I LocSend
2004-11-03 13:51:07 +00:00
or
2007-09-20 16:26:31 +00:00
.I None
2004-11-03 13:51:07 +00:00
whereas
2007-09-20 16:26:31 +00:00
.I SymOrRem
is the default.
The different modes have the following meaning:
2004-11-03 13:51:07 +00:00
.br
2007-09-20 16:26:31 +00:00
.I Sym
2005-10-24 09:14:25 +00:00
= Symmetric
2004-11-03 13:51:07 +00:00
both link partners are allowed to send PAUSE frames
.br
2007-09-20 16:26:31 +00:00
.I SymOrRem
2005-10-24 09:14:25 +00:00
= SymmetricOrRemote
2004-11-03 13:51:07 +00:00
both or only remote partner are allowed to send PAUSE frames
.br
2007-09-20 16:26:31 +00:00
.I LocSend
2004-11-03 13:51:07 +00:00
= LocalSend
only local link partner is allowed to send PAUSE frames
.br
2007-09-20 16:26:31 +00:00
.I None
2004-11-03 13:51:07 +00:00
= None
no link partner is allowed to send PAUSE frames
Note that this parameter is ignored if AutoNeg_A is set to
.IR Off .
.TP
.BI FlowCtrl_B= i,j,...
This parameter can be used to set the flow control capabilities the
port reports during auto-negotiation.
2006-12-27 03:54:41 +00:00
Possible values are:
2005-10-24 08:55:52 +00:00
.IR Sym ,
.IR SymOrRem ,
2007-09-20 16:26:31 +00:00
.I LocSend
2004-11-03 13:51:07 +00:00
or
2007-09-20 16:26:31 +00:00
.I None
2004-11-03 13:51:07 +00:00
whereas
2007-09-20 16:26:31 +00:00
.I SymOrRem
is the default.
The different modes have the following meaning:
2004-11-03 13:51:07 +00:00
2007-09-20 16:26:31 +00:00
.I Sym
2004-11-03 13:51:07 +00:00
= Symmetric
both link partners are allowed to send PAUSE frames
.br
2007-09-20 16:26:31 +00:00
.I SymOrRem
2004-11-03 13:51:07 +00:00
= SymmetricOrRemote
both or only remote partner are allowed to send PAUSE frames
.br
2007-09-20 16:26:31 +00:00
.I LocSend
2004-11-03 13:51:07 +00:00
= LocalSend
only local link partner is allowed to send PAUSE frames
.br
2007-09-20 16:26:31 +00:00
.I None
2004-11-03 13:51:07 +00:00
= None
no link partner is allowed to send PAUSE frames
.br
Note that this parameter is ignored if AutoNeg_B is set to
.IR Off .
.TP
.BI Role_A= i,j,...
This parameter is only valid for 1000Base-T adapter cards.
For two 1000Base-T ports to communicate,
one must take the role of the master (providing timing information),
while the other must be the slave.
2006-12-27 03:54:41 +00:00
Possible values are:
2005-10-24 08:55:52 +00:00
.IR Auto ,
2007-09-20 16:26:31 +00:00
.I Master
2004-11-03 13:51:07 +00:00
or
2007-09-20 16:26:31 +00:00
.I Slave
2004-11-03 13:51:07 +00:00
whereas
2007-09-20 16:26:31 +00:00
.I Auto
is the default.
Usually, the role of a port is negotiated between two ports during
link establishment, but if that fails the port A of an adapter card
2006-12-27 03:54:41 +00:00
can be forced to a specific setting with this parameter.
2004-11-03 13:51:07 +00:00
.TP
.BI Role_B= i,j,...
This parameter is only valid for 1000Base-T adapter cards.
For two 1000Base-T ports to communicate, one must take
the role of the master (providing timing information),
while the other must be the slave.
2006-12-27 03:54:41 +00:00
Possible values are:
2005-10-24 08:55:52 +00:00
.IR Auto ,
2007-09-20 16:26:31 +00:00
.I Master
2004-11-03 13:51:07 +00:00
or
2007-09-20 16:26:31 +00:00
.I Slave
2004-11-03 13:51:07 +00:00
whereas
2007-09-20 16:26:31 +00:00
.I Auto
is the default.
Usually, the role of a port is negotiated between
two ports during link establishment, but if that fails
the port B of an adapter card can be forced to a
2006-12-27 03:54:41 +00:00
specific setting with this parameter.
2004-11-03 13:51:07 +00:00
.TP
.BI ConType= i,j,...
This parameter is a combination of all five per-port parameters
within one single parameter.
This simplifies the configuration of both ports of an adapter card.
The different values of this variable reflect the
most meaningful combinations of port parameters.
2006-12-27 03:54:41 +00:00
Possible values and their corresponding combination of per-port parameters:
2004-11-03 13:51:07 +00:00
.br
.ad l
ConType | DupCap AutoNeg FlowCtrl Role Speed
--------+-------------------------------------------
.br
.IR Auto \c
| Both On SymOrRem Auto Auto
.br
.IR 100FD \c
| Full Off None Auto 100
.br
.IR 100HD \c
| Half Off None Auto 100
.br
.IR 10FD \c
| Full Off None Auto 10
.br
.IR 10HD \c
| Half Off None Auto 10
2005-10-24 09:14:25 +00:00
.ad b
Stating any other port parameter together with this
2007-09-20 16:26:31 +00:00
.I ConType
parameter will result in a merged configuration of those settings.
2006-12-27 03:54:41 +00:00
This is due to
2005-10-24 09:14:25 +00:00
the fact, that the per-port parameters (e.g.
.IR Speed_A )
have a higher priority than the combined variable
2005-10-24 13:01:46 +00:00
.IR ConType .
2004-11-03 13:51:07 +00:00
.TP
.BI Moderation= i,j,...
Interrupt moderation is employed to limit the maximum number of interrupts
the driver has to serve.
That is, one or more interrupts (which indicate any transmit or
receive packet to be processed) are queued until the driver processes them.
2006-12-27 03:54:41 +00:00
When queued interrupts are to be served, is determined by the
2007-09-20 16:26:31 +00:00
.I IntsPerSec
parameter, which is explained later below.
Possible moderation modes are:
2005-10-24 08:55:52 +00:00
.IR None ,
2007-09-20 16:26:31 +00:00
.I Static
2004-11-03 13:51:07 +00:00
or
2007-09-20 16:26:31 +00:00
.I Dynamic
2004-11-03 13:51:07 +00:00
whereas
2007-09-20 16:26:31 +00:00
.I None
is the default.
The different modes have the following meaning:
2004-11-03 13:51:07 +00:00
2007-09-20 16:26:31 +00:00
.I None
No interrupt moderation is applied on the adapter card.
Therefore, each transmit or receive interrupt is served immediately
2006-12-27 03:54:41 +00:00
as soon as it appears on the interrupt line of the adapter card.
2004-11-03 13:51:07 +00:00
.br
2007-09-20 16:26:31 +00:00
.I Static
Interrupt moderation is applied on the adapter card.
All transmit and receive interrupts are queued until
a complete moderation interval ends.
If such a moderation interval ends, all queued interrupts
are processed in one big bunch without any delay.
2006-12-27 03:54:41 +00:00
The term
2007-09-20 16:26:31 +00:00
.I Static
reflects the fact, that interrupt moderation is always enabled,
regardless how much network load is currently passing via a
particular interface.
In addition, the duration of the moderation interval has a fixed
2006-12-27 03:54:41 +00:00
length that never changes while the driver is operational.
2004-11-03 13:51:07 +00:00
.br
2007-09-20 16:26:31 +00:00
.I Dynamic
Interrupt moderation might be applied on the adapter card,
depending on the load of the system.
If the driver detects that the system load is too high,
the driver tries to shield the system against too much network
load by enabling interrupt moderation.
If \(em at a later time \(em the CPU utilization decreases
again (or if the network load is negligible) the interrupt
2006-12-27 03:54:41 +00:00
moderation will automatically be disabled.
Interrupt moderation should be used when the driver has to
handle one or more interfaces with a high network load,
which \(em as a consequence \(em leads also to a high CPU utilization.
When moderation is applied in such high network load situations,
2006-12-27 03:54:41 +00:00
CPU load might be reduced by 20-30% on slow computers.
Note that the drawback of using interrupt moderation is an increase of
the round-trip-time (RTT), due to the queuing and serving of
2006-12-27 03:54:41 +00:00
interrupts at dedicated moderation times.
2004-11-03 13:51:07 +00:00
.TP
.BI IntsPerSec= i,j,...
This parameter determines the length of any interrupt moderation interval.
2005-10-24 09:14:25 +00:00
Assuming that static interrupt moderation is to be used, an
2007-09-20 16:26:31 +00:00
.I IntsPerSec
2004-11-03 13:51:07 +00:00
parameter value of 2000 will lead to an interrupt moderation interval of
500 microseconds.
Possible values for this parameter are in the range of
30...40000 (interrupts per second).
2006-12-27 03:54:41 +00:00
The default value is 2000.
2004-11-03 13:51:07 +00:00
This parameter is only used, if either static or dynamic interrupt moderation
is enabled on a network adapter card.
2006-12-27 03:54:41 +00:00
This parameter is ignored if no moderation is applied.
2004-11-03 13:51:07 +00:00
Note that the duration of the moderation interval is to be chosen with care.
At first glance, selecting a very long duration (e.g., only 100 interrupts per
2004-11-03 13:51:07 +00:00
second) seems to be meaningful, but the increase of packet-processing delay
is tremendous.
On the other hand, selecting a very short moderation time might
2004-11-03 13:51:07 +00:00
compensate the use of any moderation being applied.
.TP
.BI PrefPort= i,j,...
This parameter is used to force the preferred port to
A or B (on dual-port network adapters).
The preferred port is the one that is used if both ports A and B are
detected as fully functional.
2006-12-27 03:54:41 +00:00
Possible values are:
2007-09-20 16:26:31 +00:00
.I A
2004-11-03 13:51:07 +00:00
or
2007-09-20 16:26:31 +00:00
.I B
2004-11-03 13:51:07 +00:00
whereas
2007-09-20 16:26:31 +00:00
.I A
2004-11-03 13:51:07 +00:00
is the default.
.TP
.BI RlmtMode= i,j,...
RLMT monitors the status of the port.
If the link of the active port fails,
RLMT switches immediately to the standby link.
2006-12-27 03:54:41 +00:00
The virtual link is maintained as long as at least one 'physical' link is up.
This parameters states how RLMT should monitor both ports.
2006-12-27 03:54:41 +00:00
Possible values are:
2005-10-24 08:55:52 +00:00
.IR CheckLinkState ,
.IR CheckLocalPort ,
2007-09-20 16:26:31 +00:00
.I CheckSeg
2004-11-03 13:51:07 +00:00
or
2007-09-20 16:26:31 +00:00
.I DualNet
2004-11-03 13:51:07 +00:00
whereas
2007-09-20 16:26:31 +00:00
.I CheckLinkState
is the default.
The different modes have the following meaning:
2004-11-03 13:51:07 +00:00
2007-09-20 16:26:31 +00:00
.I CheckLinkState
Check link state only: RLMT uses the link state reported by the adapter
hardware for each individual port to determine whether a port can be used
2006-12-27 03:54:41 +00:00
for all network traffic or not.
2004-11-03 13:51:07 +00:00
.br
2007-09-20 16:26:31 +00:00
.I CheckLocalPort
In this mode, RLMT monitors the network path between the two
ports of an adapter by regularly exchanging packets between them.
This mode requires a network configuration in which the
two ports are able to "see" each other (i.e., there
2006-12-27 03:54:41 +00:00
must not be any router between the ports).
2004-11-03 13:51:07 +00:00
.br
2007-09-20 16:26:31 +00:00
.I CheckSeg
Check local port and segmentation:
This mode supports the same functions as the CheckLocalPort
mode and additionally checks network segmentation between the ports.
Therefore, this mode is only to be used if Gigabit Ethernet
switches are installed on the network that have been
2006-12-27 03:54:41 +00:00
configured to use the Spanning Tree protocol.
2004-11-03 13:51:07 +00:00
.br
2007-09-20 16:26:31 +00:00
.I DualNet
In this mode, ports A and B are used as separate devices.
2006-12-27 03:54:41 +00:00
If you have a dual port adapter, port A will be configured as
2005-10-24 09:14:25 +00:00
.IR eth[x] and port B as
.IR eth[x+1] .
Both ports can be used independently with distinct IP addresses.
The preferred port setting is not used.
RLMT is turned off.
2004-11-03 13:51:07 +00:00
2005-10-24 09:14:25 +00:00
Note that RLMT modes
2007-09-20 16:26:31 +00:00
.I CheckLocalPort
2005-10-24 09:14:25 +00:00
and
2007-09-20 16:26:31 +00:00
.I CheckLinkState
are designed to operate in configurations where a
network path between the ports on one adapter exists.
Moreover, they are not designed to work where adapters are
2006-12-27 03:54:41 +00:00
connected back-to-back.
2004-11-03 13:51:07 +00:00
.SH FILES
.TP
2005-11-02 13:55:25 +00:00
.I /proc/net/sk98lin/eth[x]
2005-10-24 09:14:25 +00:00
.br
The statistics file of a particular interface of an adapter card.
It contains generic information about the adapter card plus a detailed
2006-12-27 03:54:41 +00:00
summary of all transmit and receive counters.
2004-11-03 13:51:07 +00:00
.TP
.I /usr/src/linux/Documentation/networking/sk98lin.txt
2005-10-24 09:14:25 +00:00
.br
This is the
2007-09-20 16:26:31 +00:00
.I README
2005-10-24 09:14:25 +00:00
file of the
2007-09-20 16:26:31 +00:00
.I sk98lin
driver.
It contains a detailed installation HOWTO and describes all parameters
of the driver.
2006-12-27 03:54:41 +00:00
It denotes also common problems and provides the solution to them.
2004-11-03 13:51:07 +00:00
.SH BUGS
Report any bugs to linux@syskonnect.de
2007-06-08 12:01:06 +00:00
.\" .SH AUTHORS
.\" Ralph Roesler \(em rroesler@syskonnect.de
.\" .br
.\" Mirko Lindner \(em mlindner@syskonnect.de
2004-11-03 13:51:07 +00:00
.SH "SEE ALSO"
2005-10-24 09:14:25 +00:00
.BR modprobe (8),
.BR insmod (8),
2007-05-22 21:49:38 +00:00
.BR ifconfig (8)