RAID stands for ''Redundant Array of Inexpensive Disks'', and is meant
|
|
to be a way of creating a fast and reliable disk-drive subsystem out
|
|
of individual disks. RAID can guard against disk failure, and can
|
|
also improve performance over that of a single disk drive. This docu-
|
|
ment is a tutorial/HOWTO/FAQ for users of the Linux MD kernel exten-
|
|
sion, the associated tools, and their use. The MD extension imple-
|
|
ments RAID-0 (striping), RAID-1 (mirroring), RAID-4 and RAID-5 in
|
|
software. That is, with MD, no special hardware or disk controllers
|
|
are required to get many of the benefits of RAID.
|
|
______________________________________________________________________
|
|
|
|
Table of Contents
|
|
|
|
|
|
1. Introduction
|
|
|
|
2. Understanding RAID
|
|
|
|
3. Setup & Installation Considerations
|
|
|
|
4. Error Recovery
|
|
|
|
5. Troubleshooting Install Problems
|
|
|
|
6. Supported Hardware & Software
|
|
|
|
7. Modifying an Existing Installation
|
|
|
|
8. Performance, Tools & General Bone-headed Questions
|
|
|
|
9. High Availability RAID
|
|
|
|
10. Questions Waiting for Answers
|
|
|
|
11. Wish List of Enhancements to MD and Related Software
|
|
|
|
|
|
|
|
______________________________________________________________________
|
|
|
|
|
|
Preamble
|
|
This document is copyrighted and GPL'ed by Linas Vepstas
|
|
(linas@linas.org). Permission to use, copy, distribute this
|
|
document for any purpose is hereby granted, provided that the
|
|
author's / editor's name and this notice appear in all copies
|
|
and/or supporting documents; and that an unmodified version of
|
|
this document is made freely available. This document is
|
|
distributed in the hope that it will be useful, but WITHOUT ANY
|
|
WARRANTY, either expressed or implied. While every effort has
|
|
been taken to ensure the accuracy of the information documented
|
|
herein, the author / editor / maintainer assumes NO
|
|
RESPONSIBILITY for any errors, or for any damages, direct or
|
|
consequential, as a result of the use of the information
|
|
documented herein.
|
|
|
|
|
|
RAID, although designed to improve system reliability by adding
|
|
redundancy, can also lead to a false sense of security and
|
|
confidence when used improperly. This false confidence can lead
|
|
to even greater disasters. In particular, note that RAID is
|
|
designed to protect against *disk* failures, and not against
|
|
*power* failures or *operator* mistakes. Power failures, buggy
|
|
development kernels, or operator/admin errors can lead to
|
|
damaged data that it is not recoverable! RAID is *not* a
|
|
substitute for proper backup of your system. Know what you are
|
|
doing, test, be knowledgeable and aware!
|
|
|
|
1. Introduction
|
|
|
|
|
|
1. Q: What is RAID?
|
|
|
|
A: RAID stands for "Redundant Array of Inexpensive Disks",
|
|
and is meant to be a way of creating a fast and reliable
|
|
disk-drive subsystem out of individual disks. In the PC
|
|
world, "I" has come to stand for "Independent", where mar-
|
|
keting forces continue to differentiate IDE and SCSI. In
|
|
it's original meaning, "I" meant "Inexpensive as compared to
|
|
refrigerator-sized mainframe 3380 DASD", monster drives
|
|
which made nice houses look cheap, and diamond rings look
|
|
like trinkets.
|
|
|
|
|
|
|
|
2. Q: What is this document?
|
|
|
|
A: This document is a tutorial/HOWTO/FAQ for users of the
|
|
Linux MD kernel extension, the associated tools, and their
|
|
use. The MD extension implements RAID-0 (striping), RAID-1
|
|
(mirroring), RAID-4 and RAID-5 in software. That is, with
|
|
MD, no special hardware or disk controllers are required to
|
|
get many of the benefits of RAID.
|
|
|
|
|
|
This document is NOT an introduction to RAID; you must find
|
|
this elsewhere.
|
|
|
|
|
|
|
|
3. Q: What levels of RAID does the Linux kernel implement?
|
|
|
|
A: Striping (RAID-0) and linear concatenation are a part of
|
|
the stock 2.x series of kernels. This code is of production
|
|
quality; it is well understood and well maintained. It is
|
|
being used in some very large USENET news servers.
|
|
|
|
|
|
RAID-1, RAID-4 & RAID-5 are a part of the 2.1.63 and greater
|
|
kernels. For earlier 2.0.x and 2.1.x kernels, patches exist
|
|
that will provide this function. Don't feel obligated to
|
|
upgrade to 2.1.63; upgrading the kernel is hard; it is
|
|
*much* easier to patch an earlier kernel. Most of the RAID
|
|
user community is running 2.0.x kernels, and that's where
|
|
most of the historic RAID development has focused. The
|
|
current snapshots should be considered near-production
|
|
quality; that is, there are no known bugs but there are some
|
|
rough edges and untested system setups. There are a large
|
|
number of people using Software RAID in a production
|
|
environment.
|
|
|
|
|
|
RAID-1 hot reconstruction has been recently introduced
|
|
(August 1997) and should be considered alpha quality.
|
|
RAID-5 hot reconstruction will be alpha quality any day now.
|
|
|
|
|
|
A word of caution about the 2.1.x development kernels: these
|
|
are less than stable in a variety of ways. Some of the
|
|
newer disk controllers (e.g. the Promise Ultra's) are
|
|
supported only in the 2.1.x kernels. However, the 2.1.x
|
|
kernels have seen frequent changes in the block device
|
|
driver, in the DMA and interrupt code, in the PCI, IDE and
|
|
SCSI code, and in the disk controller drivers. The
|
|
combination of these factors, coupled to cheapo hard drives
|
|
and/or low-quality ribbon cables can lead to considerable
|
|
heartbreak. The ckraid tool, as well as fsck and mount put
|
|
considerable stress on the RAID subsystem. This can lead to
|
|
hard lockups during boot, where even the magic alt-SysReq
|
|
key sequence won't save the day. Use caution with the 2.1.x
|
|
kernels, and expect trouble. Or stick to the 2.0.34 kernel.
|
|
|
|
|
|
|
|
4. Q: I'm running an older kernel. Where do I get patches?
|
|
|
|
A: Software RAID-0 and linear mode are a stock part of all
|
|
current Linux kernels. Patches for Software RAID-1,4,5 are
|
|
available from
|
|
<http://luthien.nuclecu.unam.mx/~miguel/raid>. See also the
|
|
quasi-mirror <ftp://linux.kernel.org/pub/linux/dae-
|
|
mons/raid/> for patches, tools and other goodies.
|
|
|
|
|
|
|
|
5. Q: Are there other Linux RAID references?
|
|
|
|
A:
|
|
|
|
o Generic RAID overview:
|
|
<http://www.dpt.com/uraiddoc.html>.
|
|
|
|
o General Linux RAID options:
|
|
<http://linas.org/linux/raid.html>.
|
|
|
|
o Latest version of this document:
|
|
<http://linas.org/linux/Software-RAID/Software-
|
|
RAID.html>.
|
|
|
|
o Linux-RAID mailing list archive:
|
|
<http://www.linuxhq.com/lnxlists/>.
|
|
|
|
o Linux Software RAID Home Page:
|
|
<http://luthien.nuclecu.unam.mx/~miguel/raid>.
|
|
|
|
o Linux Software RAID tools:
|
|
<ftp://linux.kernel.org/pub/linux/daemons/raid/>.
|
|
|
|
o How to setting up linear/stripped Software RAID:
|
|
<http://www.ssc.com/lg/issue17/raid.html>.
|
|
|
|
o Bootable RAID mini-HOWTO:
|
|
<ftp://ftp.bizsystems.com/pub/raid/bootable-raid>.
|
|
|
|
o Root RAID HOWTO: <ftp://ftp.bizsystems.com/pub/raid/Root-
|
|
RAID-HOWTO>.
|
|
|
|
o Linux RAID-Geschichten:
|
|
<http://www.infodrom.north.de/~joey/Linux/raid/>.
|
|
|
|
|
|
|
|
6. Q: Who do I blame for this document?
|
|
|
|
A: Linas Vepstas slapped this thing together. However, most
|
|
of the information, and some of the words were supplied by
|
|
|
|
o Bradley Ward Allen <ulmo@Q.Net>
|
|
|
|
o Luca Berra <bluca@comedia.it>
|
|
|
|
o Brian Candler <B.Candler@pobox.com>
|
|
|
|
o Bohumil Chalupa <bochal@apollo.karlov.mff.cuni.cz>
|
|
|
|
o Rob Hagopian <hagopiar@vu.union.edu>
|
|
|
|
o Anton Hristozov <anton@intransco.com>
|
|
|
|
o Miguel de Icaza <miguel@luthien.nuclecu.unam.mx>
|
|
|
|
o Marco Meloni <tonno@stud.unipg.it>
|
|
|
|
o Ingo Molnar <mingo@pc7537.hil.siemens.at>
|
|
|
|
o Alvin Oga <alvin@planet.fef.com>
|
|
|
|
o Gadi Oxman <gadio@netvision.net.il>
|
|
|
|
o Vaughan Pratt <pratt@cs.Stanford.EDU>
|
|
|
|
o Steven A. Reisman <sar@pressenter.com>
|
|
|
|
o Michael Robinton <michael@bzs.org>
|
|
|
|
o Martin Schulze <joey@finlandia.infodrom.north.de>
|
|
|
|
o Geoff Thompson <geofft@cs.waikato.ac.nz>
|
|
|
|
o Edward Welbon <welbon@bga.com>
|
|
|
|
o Rod Wilkens <rwilkens@border.net>
|
|
|
|
o Johan Wiltink <j.m.wiltink@pi.net>
|
|
|
|
o Leonard N. Zubkoff <lnz@dandelion.com>
|
|
|
|
o Marc ZYNGIER <zyngier@ufr-info-p7.ibp.fr>
|
|
|
|
|
|
Copyrights
|
|
|
|
o Copyright (C) 1994-96 Marc ZYNGIER
|
|
|
|
o Copyright (C) 1997 Gadi Oxman, Ingo Molnar, Miguel de
|
|
Icaza
|
|
|
|
o Copyright (C) 1997, 1998 Linas Vepstas
|
|
|
|
o By copyright law, additional copyrights are implicitly
|
|
held by the contributors listed above.
|
|
|
|
Thanks all for being there!
|
|
|
|
|
|
|
|
2. Understanding RAID
|
|
|
|
|
|
1. Q: What is RAID? Why would I ever use it?
|
|
|
|
A: RAID is a way of combining multiple disk drives into a
|
|
single entity to improve performance and/or reliability.
|
|
There are a variety of different types and implementations
|
|
of RAID, each with its own advantages and disadvantages.
|
|
For example, by putting a copy of the same data on two disks
|
|
(called disk mirroring, or RAID level 1), read performance
|
|
can be improved by reading alternately from each disk in the
|
|
mirror. On average, each disk is less busy, as it is han-
|
|
dling only 1/2 the reads (for two disks), or 1/3 (for three
|
|
disks), etc. In addition, a mirror can improve reliability:
|
|
if one disk fails, the other disk(s) have a copy of the
|
|
data. Different ways of combining the disks into one,
|
|
referred to as RAID levels, can provide greater storage
|
|
efficiency than simple mirroring, or can alter latency
|
|
(access-time) performance, or throughput (transfer rate)
|
|
performance, for reading or writing, while still retaining
|
|
redundancy that is useful for guarding against failures.
|
|
|
|
Although RAID can protect against disk failure, it does not
|
|
protect against operator and administrator (human) error, or
|
|
against loss due to programming bugs (possibly due to bugs
|
|
in the RAID software itself). The net abounds with tragic
|
|
tales of system administrators who have bungled a RAID
|
|
installation, and have lost all of their data. RAID is not
|
|
a substitute for frequent, regularly scheduled backup.
|
|
|
|
RAID can be implemented in hardware, in the form of special
|
|
disk controllers, or in software, as a kernel module that is
|
|
layered in between the low-level disk driver, and the file
|
|
system which sits above it. RAID hardware is always a "disk
|
|
controller", that is, a device to which one can cable up the
|
|
disk drives. Usually it comes in the form of an adapter card
|
|
that will plug into a ISA/EISA/PCI/S-Bus/MicroChannel slot.
|
|
However, some RAID controllers are in the form of a box that
|
|
connects into the cable in between the usual system disk
|
|
controller, and the disk drives. Small ones may fit into a
|
|
drive bay; large ones may be built into a storage cabinet
|
|
with its own drive bays and power supply. The latest RAID
|
|
hardware used with the latest & fastest CPU will usually
|
|
provide the best overall performance, although at a
|
|
significant price. This is because most RAID controllers
|
|
come with on-board DSP's and memory cache that can off-load
|
|
a considerable amount of processing from the main CPU, as
|
|
well as allow high transfer rates into the large controller
|
|
cache. Old RAID hardware can act as a "de-accelerator" when
|
|
used with newer CPU's: yesterday's fancy DSP and cache can
|
|
act as a bottleneck, and it's performance is often beaten by
|
|
pure-software RAID and new but otherwise plain, run-of-the-
|
|
mill disk controllers. RAID hardware can offer an advantage
|
|
over pure-software RAID, if it can makes use of disk-spindle
|
|
synchronization and its knowledge of the disk-platter
|
|
position with regard to the disk head, and the desired disk-
|
|
block. However, most modern (low-cost) disk drives do not
|
|
offer this information and level of control anyway, and
|
|
thus, most RAID hardware does not take advantage of it.
|
|
RAID hardware is usually not compatible across different
|
|
brands, makes and models: if a RAID controller fails, it
|
|
must be replaced by another controller of the same type. As
|
|
of this writing (June 1998), a broad variety of hardware
|
|
controllers will operate under Linux; however, none of them
|
|
currently come with configuration and management utilities
|
|
that run under Linux.
|
|
|
|
Software-RAID is a set of kernel modules, together with
|
|
management utilities that implement RAID purely in software,
|
|
and require no extraordinary hardware. The Linux RAID
|
|
subsystem is implemented as a layer in the kernel that sits
|
|
above the low-level disk drivers (for IDE, SCSI and Paraport
|
|
drives), and the block-device interface. The filesystem, be
|
|
it ext2fs, DOS-FAT, or other, sits above the block-device
|
|
interface. Software-RAID, by its very software nature,
|
|
tends to be more flexible than a hardware solution. The
|
|
downside is that it of course requires more CPU cycles and
|
|
power to run well than a comparable hardware system. Of
|
|
course, the cost can't be beat. Software RAID has one
|
|
further important distinguishing feature: it operates on a
|
|
partition-by-partition basis, where a number of individual
|
|
disk partitions are ganged together to create a RAID
|
|
partition. This is in contrast to most hardware RAID
|
|
solutions, which gang together entire disk drives into an
|
|
array. With hardware, the fact that there is a RAID array
|
|
is transparent to the operating system, which tends to
|
|
simplify management. With software, there are far more
|
|
configuration options and choices, tending to complicate
|
|
matters.
|
|
|
|
As of this writing (June 1998), the administration of RAID
|
|
under Linux is far from trivial, and is best attempted by
|
|
experienced system administrators. The theory of operation
|
|
is complex. The system tools require modification to
|
|
startup scripts. And recovery from disk failure is non-
|
|
trivial, and prone to human error. RAID is not for the
|
|
novice, and any benefits it may bring to reliability and
|
|
performance can be easily outweighed by the extra
|
|
complexity. Indeed, modern disk drives are incredibly
|
|
reliable and modern CPU's and controllers are quite
|
|
powerful. You might more easily obtain the desired
|
|
reliability and performance levels by purchasing higher-
|
|
quality and/or faster hardware.
|
|
|
|
|
|
|
|
2. Q: What are RAID levels? Why so many? What distinguishes them?
|
|
|
|
A: The different RAID levels have different performance,
|
|
redundancy, storage capacity, reliability and cost charac-
|
|
teristics. Most, but not all levels of RAID offer redun-
|
|
dancy against disk failure. Of those that offer redundancy,
|
|
RAID-1 and RAID-5 are the most popular. RAID-1 offers bet-
|
|
ter performance, while RAID-5 provides for more efficient
|
|
use of the available storage space. However, tuning for
|
|
performance is an entirely different matter, as performance
|
|
depends strongly on a large variety of factors, from the
|
|
type of application, to the sizes of stripes, blocks, and
|
|
files. The more difficult aspects of performance tuning are
|
|
deferred to a later section of this HOWTO.
|
|
|
|
The following describes the different RAID levels in the
|
|
context of the Linux software RAID implementation.
|
|
|
|
|
|
o RAID-linear is a simple concatenation of partitions to
|
|
create a larger virtual partition. It is handy if you
|
|
have a number small drives, and wish to create a single,
|
|
large partition. This concatenation offers no
|
|
redundancy, and in fact decreases the overall
|
|
reliability: if any one disk fails, the combined
|
|
partition will fail.
|
|
|
|
|
|
|
|
o RAID-1 is also referred to as "mirroring". Two (or more)
|
|
partitions, all of the same size, each store an exact
|
|
copy of all data, disk-block by disk-block. Mirroring
|
|
gives strong protection against disk failure: if one disk
|
|
fails, there is another with the an exact copy of the
|
|
same data. Mirroring can also help improve performance in
|
|
I/O-laden systems, as read requests can be divided up
|
|
between several disks. Unfortunately, mirroring is also
|
|
the least efficient in terms of storage: two mirrored
|
|
partitions can store no more data than a single
|
|
partition.
|
|
|
|
|
|
|
|
o Striping is the underlying concept behind all of the
|
|
other RAID levels. A stripe is a contiguous sequence of
|
|
disk blocks. A stripe may be as short as a single disk
|
|
block, or may consist of thousands. The RAID drivers
|
|
split up their component disk partitions into stripes;
|
|
the different RAID levels differ in how they organize the
|
|
stripes, and what data they put in them. The interplay
|
|
between the size of the stripes, the typical size of
|
|
files in the file system, and their location on the disk
|
|
is what determines the overall performance of the RAID
|
|
subsystem.
|
|
|
|
|
|
|
|
o RAID-0 is much like RAID-linear, except that the
|
|
component partitions are divided into stripes and then
|
|
interleaved. Like RAID-linear, the result is a single
|
|
larger virtual partition. Also like RAID-linear, it
|
|
offers no redundancy, and therefore decreases overall
|
|
reliability: a single disk failure will knock out the
|
|
whole thing. RAID-0 is often claimed to improve
|
|
performance over the simpler RAID-linear. However, this
|
|
may or may not be true, depending on the characteristics
|
|
to the file system, the typical size of the file as
|
|
compared to the size of the stripe, and the type of
|
|
workload. The ext2fs file system already scatters files
|
|
throughout a partition, in an effort to minimize
|
|
fragmentation. Thus, at the simplest level, any given
|
|
access may go to one of several disks, and thus, the
|
|
interleaving of stripes across multiple disks offers no
|
|
apparent additional advantage. However, there are
|
|
performance differences, and they are data, workload, and
|
|
stripe-size dependent.
|
|
|
|
|
|
|
|
o RAID-4 interleaves stripes like RAID-0, but it requires
|
|
an additional partition to store parity information. The
|
|
parity is used to offer redundancy: if any one of the
|
|
disks fail, the data on the remaining disks can be used
|
|
to reconstruct the data that was on the failed disk.
|
|
Given N data disks, and one parity disk, the parity
|
|
stripe is computed by taking one stripe from each of the
|
|
data disks, and XOR'ing them together. Thus, the storage
|
|
capacity of a an (N+1)-disk RAID-4 array is N, which is a
|
|
lot better than mirroring (N+1) drives, and is almost as
|
|
good as a RAID-0 setup for large N. Note that for N=1,
|
|
where there is one data drive, and one parity drive,
|
|
RAID-4 is a lot like mirroring, in that each of the two
|
|
disks is a copy of each other. However, RAID-4 does NOT
|
|
offer the read-performance of mirroring, and offers
|
|
considerably degraded write performance. In brief, this
|
|
is because updating the parity requires a read of the old
|
|
parity, before the new parity can be calculated and
|
|
written out. In an environment with lots of writes, the
|
|
parity disk can become a bottleneck, as each write must
|
|
access the parity disk.
|
|
|
|
|
|
|
|
o RAID-5 avoids the write-bottleneck of RAID-4 by
|
|
alternately storing the parity stripe on each of the
|
|
drives. However, write performance is still not as good
|
|
as for mirroring, as the parity stripe must still be read
|
|
and XOR'ed before it is written. Read performance is
|
|
also not as good as it is for mirroring, as, after all,
|
|
there is only one copy of the data, not two or more.
|
|
RAID-5's principle advantage over mirroring is that it
|
|
offers redundancy and protection against single-drive
|
|
failure, while offering far more storage capacity when
|
|
used with three or more drives.
|
|
|
|
|
|
|
|
o RAID-2 and RAID-3 are seldom used anymore, and to some
|
|
degree are have been made obsolete by modern disk
|
|
technology. RAID-2 is similar to RAID-4, but stores ECC
|
|
information instead of parity. Since all modern disk
|
|
drives incorporate ECC under the covers, this offers
|
|
little additional protection. RAID-2 can offer greater
|
|
data consistency if power is lost during a write;
|
|
however, battery backup and a clean shutdown can offer
|
|
the same benefits. RAID-3 is similar to RAID-4, except
|
|
that it uses the smallest possible stripe size. As a
|
|
result, any given read will involve all disks, making
|
|
overlapping I/O requests difficult/impossible. In order
|
|
to avoid delay due to rotational latency, RAID-3 requires
|
|
that all disk drive spindles be synchronized. Most modern
|
|
disk drives lack spindle-synchronization ability, or, if
|
|
capable of it, lack the needed connectors, cables, and
|
|
manufacturer documentation. Neither RAID-2 nor RAID-3
|
|
are supported by the Linux Software-RAID drivers.
|
|
|
|
|
|
|
|
o Other RAID levels have been defined by various
|
|
researchers and vendors. Many of these represent the
|
|
layering of one type of raid on top of another. Some
|
|
require special hardware, and others are protected by
|
|
patent. There is no commonly accepted naming scheme for
|
|
these other levels. Sometime the advantages of these
|
|
other systems are minor, or at least not apparent until
|
|
the system is highly stressed. Except for the layering
|
|
of RAID-1 over RAID-0/linear, Linux Software RAID does
|
|
not support any of the other variations.
|
|
|
|
|
|
|
|
3. Setup & Installation Considerations
|
|
|
|
|
|
1. Q: What is the best way to configure Software RAID?
|
|
|
|
|
|
A: I keep rediscovering that file-system planning is one of
|
|
the more difficult Unix configuration tasks. To answer your
|
|
question, I can describe what we did.
|
|
|
|
We planned the following setup:
|
|
|
|
o two EIDE disks, 2.1.gig each.
|
|
|
|
|
|
disk partition mount pt. size device
|
|
1 1 / 300M /dev/hda1
|
|
1 2 swap 64M /dev/hda2
|
|
1 3 /home 800M /dev/hda3
|
|
1 4 /var 900M /dev/hda4
|
|
|
|
2 1 /root 300M /dev/hdc1
|
|
2 2 swap 64M /dev/hdc2
|
|
2 3 /home 800M /dev/hdc3
|
|
2 4 /var 900M /dev/hdc4
|
|
|
|
|
|
|
|
o Each disk is on a separate controller (& ribbon cable).
|
|
The theory is that a controller failure and/or ribbon
|
|
failure won't disable both disks. Also, we might
|
|
possibly get a performance boost from parallel operations
|
|
over two controllers/cables.
|
|
|
|
o Install the Linux kernel on the root (/) partition
|
|
/dev/hda1. Mark this partition as bootable.
|
|
|
|
o /dev/hdc1 will contain a ``cold'' copy of /dev/hda1. This
|
|
is NOT a raid copy, just a plain old copy-copy. It's
|
|
there just in case the first disk fails; we can use a
|
|
rescue disk, mark /dev/hdc1 as bootable, and use that to
|
|
keep going without having to reinstall the system. You
|
|
may even want to put /dev/hdc1's copy of the kernel into
|
|
LILO to simplify booting in case of failure.
|
|
|
|
The theory here is that in case of severe failure, I can
|
|
still boot the system without worrying about raid
|
|
superblock-corruption or other raid failure modes &
|
|
gotchas that I don't understand.
|
|
|
|
o /dev/hda3 and /dev/hdc3 will be mirrors /dev/md0.
|
|
|
|
o /dev/hda4 and /dev/hdc4 will be mirrors /dev/md1.
|
|
|
|
o we picked /var and /home to be mirrored, and in separate
|
|
partitions, using the following logic:
|
|
|
|
o / (the root partition) will contain relatively static,
|
|
non-changing data: for all practical purposes, it will be
|
|
read-only without actually being marked & mounted read-
|
|
only.
|
|
|
|
o /home will contain ''slowly'' changing data.
|
|
|
|
o /var will contain rapidly changing data, including mail
|
|
spools, database contents and web server logs.
|
|
|
|
The idea behind using multiple, distinct partitions is
|
|
that if, for some bizarre reason, whether it is human
|
|
error, power loss, or an operating system gone wild,
|
|
corruption is limited to one partition. In one typical
|
|
case, power is lost while the system is writing to disk.
|
|
This will almost certainly lead to a corrupted
|
|
filesystem, which will be repaired by fsck during the
|
|
next boot. Although fsck does it's best to make the
|
|
repairs without creating additional damage during those
|
|
repairs, it can be comforting to know that any such
|
|
damage has been limited to one partition. In another
|
|
typical case, the sysadmin makes a mistake during rescue
|
|
operations, leading to erased or destroyed data.
|
|
Partitions can help limit the repercussions of the
|
|
operator's errors.
|
|
|
|
o Other reasonable choices for partitions might be /usr or
|
|
/opt. In fact, /opt and /home make great choices for
|
|
RAID-5 partitions, if we had more disks. A word of
|
|
caution: DO NOT put /usr in a RAID-5 partition. If a
|
|
serious fault occurs, you may find that you cannot mount
|
|
/usr, and that you want some of the tools on it (e.g. the
|
|
networking tools, or the compiler.) With RAID-1, if a
|
|
fault has occurred, and you can't get RAID to work, you
|
|
can at least mount one of the two mirrors. You can't do
|
|
this with any of the other RAID levels (RAID-5, striping,
|
|
or linear append).
|
|
|
|
|
|
|
|
So, to complete the answer to the question:
|
|
|
|
o install the OS on disk 1, partition 1. do NOT mount any
|
|
of the other partitions.
|
|
|
|
o install RAID per instructions.
|
|
|
|
o configure md0 and md1.
|
|
|
|
o convince yourself that you know what to do in case of a
|
|
disk failure! Discover sysadmin mistakes now, and not
|
|
during an actual crisis. Experiment! (we turned off
|
|
power during disk activity -- this proved to be ugly but
|
|
informative).
|
|
|
|
o do some ugly mount/copy/unmount/rename/reboot scheme to
|
|
move /var over to the /dev/md1. Done carefully, this is
|
|
not dangerous.
|
|
|
|
o enjoy!
|
|
|
|
|
|
|
|
2. Q: What is the difference between the mdadd, mdrun, etc. commands,
|
|
and the raidadd, raidrun commands?
|
|
|
|
A: The names of the tools have changed as of the 0.5 release
|
|
of the raidtools package. The md naming convention was used
|
|
in the 0.43 and older versions, while raid is used in 0.5
|
|
and newer versions.
|
|
|
|
|
|
|
|
3. Q: I want to run RAID-linear/RAID-0 in the stock 2.0.34 kernel. I
|
|
don't want to apply the raid patches, since these are not needed
|
|
for RAID-0/linear. Where can I get the raid-tools to manage this?
|
|
|
|
|
|
A: This is a tough question, indeed, as the newest raid
|
|
tools package needs to have the RAID-1,4,5 kernel patches
|
|
installed in order to compile. I am not aware of any pre-
|
|
compiled, binary version of the raid tools that is available
|
|
at this time. However, experiments show that the raid-tools
|
|
binaries, when compiled against kernel 2.1.100, seem to work
|
|
just fine in creating a RAID-0/linear partition under
|
|
2.0.34. A brave soul has asked for these, and I've tem-
|
|
porarily placed the binaries mdadd, mdcreate, etc. at
|
|
http://linas.org/linux/Software-RAID/ You must get the man
|
|
pages, etc. from the usual raid-tools package.
|
|
|
|
|
|
|
|
4. Q: Can I strip/mirror the root partition (/)? Why can't I boot
|
|
Linux directly from the md disks?
|
|
|
|
|
|
A: Both LILO and Loadlin need an non-stripped/mirrored par-
|
|
tition to read the kernel image from. If you want to
|
|
strip/mirror the root partition (/), then you'll want to
|
|
create an unstriped/mirrored partition to hold the ker-
|
|
nel(s). Typically, this partition is named /boot. Then you
|
|
either use the initial ramdisk support (initrd), or patches
|
|
from Harald Hoyer <HarryH@Royal.Net> that allow a stripped
|
|
partition to be used as the root device. (These patches are
|
|
now a standard part of recent 2.1.x kernels)
|
|
|
|
|
|
There are several approaches that can be used. One approach
|
|
is documented in detail in the Bootable RAID mini-HOWTO:
|
|
<ftp://ftp.bizsystems.com/pub/raid/bootable-raid>.
|
|
|
|
|
|
Alternately, use mkinitrd to build the ramdisk image, see
|
|
below.
|
|
|
|
|
|
Edward Welbon <welbon@bga.com> writes:
|
|
|
|
o ... all that is needed is a script to manage the boot
|
|
setup. To mount an md filesystem as root, the main thing
|
|
is to build an initial file system image that has the
|
|
needed modules and md tools to start md. I have a simple
|
|
script that does this.
|
|
|
|
|
|
o For boot media, I have a small cheap SCSI disk (170MB I
|
|
got it used for $20). This disk runs on a AHA1452, but
|
|
it could just as well be an inexpensive IDE disk on the
|
|
native IDE. The disk need not be very fast since it is
|
|
mainly for boot.
|
|
|
|
|
|
o This disk has a small file system which contains the
|
|
kernel and the file system image for initrd. The initial
|
|
file system image has just enough stuff to allow me to
|
|
load the raid SCSI device driver module and start the
|
|
raid partition that will become root. I then do an
|
|
|
|
|
|
echo 0x900 > /proc/sys/kernel/real-root-dev
|
|
|
|
|
|
|
|
(0x900 is for /dev/md0) and exit linuxrc. The boot proceeds
|
|
normally from there.
|
|
|
|
|
|
o I have built most support as a module except for the
|
|
AHA1452 driver that brings in the initrd filesystem. So
|
|
I have a fairly small kernel. The method is perfectly
|
|
reliable, I have been doing this since before 2.1.26 and
|
|
have never had a problem that I could not easily recover
|
|
from. The file systems even survived several 2.1.4[45]
|
|
hard crashes with no real problems.
|
|
|
|
|
|
o At one time I had partitioned the raid disks so that the
|
|
initial cylinders of the first raid disk held the kernel
|
|
and the initial cylinders of the second raid disk hold
|
|
the initial file system image, instead I made the initial
|
|
cylinders of the raid disks swap since they are the
|
|
fastest cylinders (why waste them on boot?).
|
|
|
|
|
|
o The nice thing about having an inexpensive device
|
|
dedicated to boot is that it is easy to boot from and can
|
|
also serve as a rescue disk if necessary. If you are
|
|
interested, you can take a look at the script that builds
|
|
my initial ram disk image and then runs LILO.
|
|
|
|
<http://www.realtime.net/~welbon/initrd.md.tar.gz>
|
|
|
|
|
|
It is current enough to show the picture. It isn't espe-
|
|
cially pretty and it could certainly build a much smaller
|
|
filesystem image for the initial ram disk. It would be easy
|
|
to a make it more efficient. But it uses LILO as is. If
|
|
you make any improvements, please forward a copy to me. 8-)
|
|
|
|
|
|
|
|
5. Q: I have heard that I can run mirroring over striping. Is this
|
|
true? Can I run mirroring over the loopback device?
|
|
|
|
A: Yes, but not the reverse. That is, you can put a stripe
|
|
over several disks, and then build a mirror on top of this.
|
|
However, striping cannot be put on top of mirroring.
|
|
|
|
|
|
A brief technical explanation is that the linear and stripe
|
|
personalities use the ll_rw_blk routine for access. The
|
|
ll_rw_blk routine maps disk devices and sectors, not
|
|
blocks. Block devices can be layered one on top of the
|
|
other; but devices that do raw, low-level disk accesses,
|
|
such as ll_rw_blk, cannot.
|
|
|
|
|
|
Currently (November 1997) RAID cannot be run over the
|
|
loopback devices, although this should be fixed shortly.
|
|
|
|
|
|
|
|
6. Q: I have two small disks and three larger disks. Can I
|
|
concatenate the two smaller disks with RAID-0, and then create a
|
|
RAID-5 out of that and the larger disks?
|
|
|
|
A: Currently (November 1997), for a RAID-5 array, no. Cur-
|
|
rently, one can do this only for a RAID-1 on top of the con-
|
|
catenated drives.
|
|
7. Q: What is the difference between RAID-1 and RAID-5 for a two-disk
|
|
configuration (i.e. the difference between a RAID-1 array built
|
|
out of two disks, and a RAID-5 array built out of two disks)?
|
|
|
|
|
|
A: There is no difference in storage capacity. Nor can
|
|
disks be added to either array to increase capacity (see the
|
|
question below for details).
|
|
|
|
|
|
RAID-1 offers a performance advantage for reads: the RAID-1
|
|
driver uses distributed-read technology to simultaneously
|
|
read two sectors, one from each drive, thus doubling read
|
|
performance.
|
|
|
|
|
|
The RAID-5 driver, although it contains many optimizations,
|
|
does not currently (September 1997) realize that the parity
|
|
disk is actually a mirrored copy of the data disk. Thus, it
|
|
serializes data reads.
|
|
|
|
|
|
|
|
8. Q: How can I guard against a two-disk failure?
|
|
|
|
|
|
A: Some of the RAID algorithms do guard against multiple
|
|
disk failures, but these are not currently implemented for
|
|
Linux. However, the Linux Software RAID can guard against
|
|
multiple disk failures by layering an array on top of an
|
|
array. For example, nine disks can be used to create three
|
|
raid-5 arrays. Then these three arrays can in turn be
|
|
hooked together into a single RAID-5 array on top. In fact,
|
|
this kind of a configuration will guard against a three-disk
|
|
failure. Note that a large amount of disk space is
|
|
''wasted'' on the redundancy information.
|
|
|
|
|
|
|
|
For an NxN raid-5 array,
|
|
N=3, 5 out of 9 disks are used for parity (=55%)
|
|
N=4, 7 out of 16 disks
|
|
N=5, 9 out of 25 disks
|
|
...
|
|
N=9, 17 out of 81 disks (=~20%)
|
|
|
|
|
|
|
|
In general, an MxN array will use M+N-1 disks for parity.
|
|
The least amount of space is "wasted" when M=N.
|
|
|
|
|
|
Another alternative is to create a RAID-1 array with three
|
|
disks. Note that since all three disks contain identical
|
|
data, that 2/3's of the space is ''wasted''.
|
|
|
|
|
|
|
|
9. Q: I'd like to understand how it'd be possible to have something
|
|
like fsck: if the partition hasn't been cleanly unmounted, fsck
|
|
runs and fixes the filesystem by itself more than 90% of the time.
|
|
Since the machine is capable of fixing it by itself with ckraid
|
|
--fix, why not make it automatic?
|
|
|
|
|
|
|
|
A: This can be done by adding lines like the following to
|
|
/etc/rc.d/rc.sysinit:
|
|
|
|
mdadd /dev/md0 /dev/hda1 /dev/hdc1 || {
|
|
ckraid --fix /etc/raid.usr.conf
|
|
mdadd /dev/md0 /dev/hda1 /dev/hdc1
|
|
}
|
|
|
|
|
|
|
|
or
|
|
|
|
mdrun -p1 /dev/md0
|
|
if [ $? -gt 0 ] ; then
|
|
ckraid --fix /etc/raid1.conf
|
|
mdrun -p1 /dev/md0
|
|
fi
|
|
|
|
|
|
|
|
Before presenting a more complete and reliable script, lets
|
|
review the theory of operation.
|
|
|
|
Gadi Oxman writes: In an unclean shutdown, Linux might be in
|
|
one of the following states:
|
|
|
|
o The in-memory disk cache was in sync with the RAID set
|
|
when the unclean shutdown occurred; no data was lost.
|
|
|
|
o The in-memory disk cache was newer than the RAID set
|
|
contents when the crash occurred; this results in a
|
|
corrupted filesystem and potentially in data loss.
|
|
|
|
This state can be further divided to the following two
|
|
states:
|
|
|
|
|
|
o Linux was writing data when the unclean shutdown
|
|
occurred.
|
|
|
|
o Linux was not writing data when the crash occurred.
|
|
|
|
|
|
Suppose we were using a RAID-1 array. In (2a), it might
|
|
happen that before the crash, a small number of data
|
|
blocks were successfully written only to some of the
|
|
mirrors, so that on the next reboot, the mirrors will no
|
|
longer contain the same data.
|
|
|
|
If we were to ignore the mirror differences, the
|
|
raidtools-0.36.3 read-balancing code might choose to read
|
|
the above data blocks from any of the mirrors, which will
|
|
result in inconsistent behavior (for example, the output
|
|
of e2fsck -n /dev/md0 can differ from run to run).
|
|
|
|
|
|
Since RAID doesn't protect against unclean shutdowns,
|
|
usually there isn't any ''obviously correct'' way to fix
|
|
the mirror differences and the filesystem corruption.
|
|
|
|
For example, by default ckraid --fix will choose the
|
|
first operational mirror and update the other mirrors
|
|
with its contents. However, depending on the exact
|
|
timing at the crash, the data on another mirror might be
|
|
more recent, and we might want to use it as the source
|
|
mirror instead, or perhaps use another method for
|
|
recovery.
|
|
|
|
The following script provides one of the more robust
|
|
boot-up sequences. In particular, it guards against
|
|
long, repeated ckraid's in the presence of uncooperative
|
|
disks, controllers, or controller device drivers. Modify
|
|
it to reflect your config, and copy it to rc.raid.init.
|
|
Then invoke rc.raid.init after the root partition has
|
|
been fsck'ed and mounted rw, but before the remaining
|
|
partitions are fsck'ed. Make sure the current directory
|
|
is in the search path.
|
|
|
|
mdadd /dev/md0 /dev/hda1 /dev/hdc1 || {
|
|
rm -f /fastboot # force an fsck to occur
|
|
ckraid --fix /etc/raid.usr.conf
|
|
mdadd /dev/md0 /dev/hda1 /dev/hdc1
|
|
}
|
|
# if a crash occurs later in the boot process,
|
|
# we at least want to leave this md in a clean state.
|
|
/sbin/mdstop /dev/md0
|
|
|
|
mdadd /dev/md1 /dev/hda2 /dev/hdc2 || {
|
|
rm -f /fastboot # force an fsck to occur
|
|
ckraid --fix /etc/raid.home.conf
|
|
mdadd /dev/md1 /dev/hda2 /dev/hdc2
|
|
}
|
|
# if a crash occurs later in the boot process,
|
|
# we at least want to leave this md in a clean state.
|
|
/sbin/mdstop /dev/md1
|
|
|
|
mdadd /dev/md0 /dev/hda1 /dev/hdc1
|
|
mdrun -p1 /dev/md0
|
|
if [ $? -gt 0 ] ; then
|
|
rm -f /fastboot # force an fsck to occur
|
|
ckraid --fix /etc/raid.usr.conf
|
|
mdrun -p1 /dev/md0
|
|
fi
|
|
# if a crash occurs later in the boot process,
|
|
# we at least want to leave this md in a clean state.
|
|
/sbin/mdstop /dev/md0
|
|
|
|
mdadd /dev/md1 /dev/hda2 /dev/hdc2
|
|
mdrun -p1 /dev/md1
|
|
if [ $? -gt 0 ] ; then
|
|
rm -f /fastboot # force an fsck to occur
|
|
ckraid --fix /etc/raid.home.conf
|
|
mdrun -p1 /dev/md1
|
|
fi
|
|
# if a crash occurs later in the boot process,
|
|
# we at least want to leave this md in a clean state.
|
|
/sbin/mdstop /dev/md1
|
|
|
|
# OK, just blast through the md commands now. If there were
|
|
# errors, the above checks should have fixed things up.
|
|
/sbin/mdadd /dev/md0 /dev/hda1 /dev/hdc1
|
|
/sbin/mdrun -p1 /dev/md0
|
|
|
|
/sbin/mdadd /dev/md12 /dev/hda2 /dev/hdc2
|
|
/sbin/mdrun -p1 /dev/md1
|
|
|
|
|
|
|
|
In addition to the above, you'll want to create a
|
|
rc.raid.halt which should look like the following:
|
|
|
|
/sbin/mdstop /dev/md0
|
|
/sbin/mdstop /dev/md1
|
|
|
|
|
|
|
|
Be sure to modify both rc.sysinit and init.d/halt to include
|
|
this everywhere that filesystems get unmounted before a
|
|
halt/reboot. (Note that rc.sysinit unmounts and reboots if
|
|
fsck returned with an error.)
|
|
|
|
|
|
|
|
10.
|
|
Q: Can I set up one-half of a RAID-1 mirror with the one disk I
|
|
have now, and then later get the other disk and just drop it in?
|
|
|
|
|
|
A: With the current tools, no, not in any easy way. In par-
|
|
ticular, you cannot just copy the contents of one disk onto
|
|
another, and then pair them up. This is because the RAID
|
|
drivers use glob of space at the end of the partition to
|
|
store the superblock. This decreases the amount of space
|
|
available to the file system slightly; if you just naively
|
|
try to force a RAID-1 arrangement onto a partition with an
|
|
existing filesystem, the raid superblock will overwrite a
|
|
portion of the file system and mangle data. Since the
|
|
ext2fs filesystem scatters files randomly throughput the
|
|
partition (in order to avoid fragmentation), there is a very
|
|
good chance that some file will land at the very end of a
|
|
partition long before the disk is full.
|
|
|
|
|
|
If you are clever, I suppose you can calculate how much room
|
|
the RAID superblock will need, and make your filesystem
|
|
slightly smaller, leaving room for it when you add it later.
|
|
But then, if you are this clever, you should also be able to
|
|
modify the tools to do this automatically for you. (The
|
|
tools are not terribly complex).
|
|
|
|
|
|
Note:A careful reader has pointed out that the following
|
|
trick may work; I have not tried or verified this: Do the
|
|
mkraid with /dev/null as one of the devices. Then mdadd -r
|
|
with only the single, true disk (do not mdadd /dev/null).
|
|
The mkraid should have successfully built the raid array,
|
|
while the mdadd step just forces the system to run in
|
|
"degraded" mode, as if one of the disks had failed.
|
|
|
|
|
|
|
|
4. Error Recovery
|
|
|
|
|
|
1. Q: I have a RAID-1 (mirroring) setup, and lost power while there
|
|
was disk activity. Now what do I do?
|
|
|
|
|
|
A: The redundancy of RAID levels is designed to protect
|
|
against a disk failure, not against a power failure.
|
|
|
|
There are several ways to recover from this situation.
|
|
|
|
o Method (1): Use the raid tools. These can be used to
|
|
sync the raid arrays. They do not fix file-system
|
|
damage; after the raid arrays are sync'ed, then the file-
|
|
system still has to be fixed with fsck. Raid arrays can
|
|
be checked with ckraid /etc/raid1.conf (for RAID-1, else,
|
|
/etc/raid5.conf, etc.)
|
|
|
|
Calling ckraid /etc/raid1.conf --fix will pick one of the
|
|
disks in the array (usually the first), and use that as
|
|
the master copy, and copy its blocks to the others in the
|
|
mirror.
|
|
|
|
To designate which of the disks should be used as the
|
|
master, you can use the --force-source flag: for example,
|
|
ckraid /etc/raid1.conf --fix --force-source /dev/hdc3
|
|
|
|
The ckraid command can be safely run without the --fix
|
|
option to verify the inactive RAID array without making
|
|
any changes. When you are comfortable with the proposed
|
|
changes, supply the --fix option.
|
|
|
|
|
|
o Method (2): Paranoid, time-consuming, not much better
|
|
than the first way. Lets assume a two-disk RAID-1 array,
|
|
consisting of partitions /dev/hda3 and /dev/hdc3. You
|
|
can try the following:
|
|
|
|
a. fsck /dev/hda3
|
|
|
|
b. fsck /dev/hdc3
|
|
|
|
c. decide which of the two partitions had fewer errors,
|
|
or were more easily recovered, or recovered the data
|
|
that you wanted. Pick one, either one, to be your new
|
|
``master'' copy. Say you picked /dev/hdc3.
|
|
|
|
d. dd if=/dev/hdc3 of=/dev/hda3
|
|
|
|
e. mkraid raid1.conf -f --only-superblock
|
|
|
|
|
|
Instead of the last two steps, you can instead run ckraid
|
|
/etc/raid1.conf --fix --force-source /dev/hdc3 which
|
|
should be a bit faster.
|
|
|
|
o Method (3): Lazy man's version of above. If you don't
|
|
want to wait for long fsck's to complete, it is perfectly
|
|
fine to skip the first three steps above, and move
|
|
directly to the last two steps. Just be sure to run fsck
|
|
/dev/md0 after you are done. Method (3) is actually just
|
|
method (1) in disguise.
|
|
|
|
|
|
In any case, the above steps will only sync up the raid
|
|
arrays. The file system probably needs fixing as well:
|
|
for this, fsck needs to be run on the active, unmounted
|
|
md device.
|
|
|
|
|
|
With a three-disk RAID-1 array, there are more
|
|
possibilities, such as using two disks to ''vote'' a
|
|
majority answer. Tools to automate this do not currently
|
|
(September 97) exist.
|
|
|
|
|
|
|
|
2. Q: I have a RAID-4 or a RAID-5 (parity) setup, and lost power while
|
|
there was disk activity. Now what do I do?
|
|
|
|
|
|
A: The redundancy of RAID levels is designed to protect
|
|
against a disk failure, not against a power failure.
|
|
|
|
Since the disks in a RAID-4 or RAID-5 array do not contain a
|
|
file system that fsck can read, there are fewer repair
|
|
options. You cannot use fsck to do preliminary checking
|
|
and/or repair; you must use ckraid first.
|
|
|
|
|
|
The ckraid command can be safely run without the --fix
|
|
option to verify the inactive RAID array without making any
|
|
changes. When you are comfortable with the proposed
|
|
changes, supply the --fix option.
|
|
|
|
|
|
If you wish, you can try designating one of the disks as a
|
|
''failed disk''. Do this with the --suggest-failed-disk-
|
|
mask flag.
|
|
|
|
Only one bit should be set in the flag: RAID-5 cannot
|
|
recover two failed disks. The mask is a binary bit mask:
|
|
thus:
|
|
|
|
0x1 == first disk
|
|
0x2 == second disk
|
|
0x4 == third disk
|
|
0x8 == fourth disk, etc.
|
|
|
|
|
|
|
|
Alternately, you can choose to modify the parity sectors, by
|
|
using the --suggest-fix-parity flag. This will recompute
|
|
the parity from the other sectors.
|
|
|
|
|
|
The flags --suggest-failed-dsk-mask and --suggest-fix-parity
|
|
can be safely used for verification. No changes are made if
|
|
the --fix flag is not specified. Thus, you can experiment
|
|
with different possible repair schemes.
|
|
|
|
|
|
|
|
3. Q: My RAID-1 device, /dev/md0 consists of two hard drive
|
|
partitions: /dev/hda3 and /dev/hdc3. Recently, the disk with
|
|
/dev/hdc3 failed, and was replaced with a new disk. My best
|
|
friend, who doesn't understand RAID, said that the correct thing to
|
|
do now is to ''dd if=/dev/hda3 of=/dev/hdc3''. I tried this, but
|
|
things still don't work.
|
|
|
|
|
|
A: You should keep your best friend away from you computer.
|
|
Fortunately, no serious damage has been done. You can
|
|
recover from this by running:
|
|
|
|
|
|
mkraid raid1.conf -f --only-superblock
|
|
|
|
|
|
|
|
By using dd, two identical copies of the partition were cre-
|
|
ated. This is almost correct, except that the RAID-1 kernel
|
|
extension expects the RAID superblocks to be different.
|
|
Thus, when you try to reactivate RAID, the software will
|
|
notice the problem, and deactivate one of the two parti-
|
|
tions. By re-creating the superblock, you should have a
|
|
fully usable system.
|
|
|
|
|
|
|
|
4. Q: My version of mkraid doesn't have a --only-superblock flag.
|
|
What do I do?
|
|
|
|
A: The newer tools drop support for this flag, replacing it
|
|
with the --force-resync flag. It has been reported that the
|
|
following sequence appears to work with the latest tools and
|
|
software:
|
|
|
|
|
|
umount /web (where /dev/md0 was mounted on)
|
|
raidstop /dev/md0
|
|
mkraid /dev/md0 --force-resync --really-force
|
|
raidstart /dev/md0
|
|
|
|
|
|
|
|
After doing this, a cat /proc/mdstat should report resync in
|
|
progress, and one should be able to mount /dev/md0 at this
|
|
point.
|
|
|
|
|
|
|
|
5. Q: My RAID-1 device, /dev/md0 consists of two hard drive
|
|
partitions: /dev/hda3 and /dev/hdc3. My best (girl?)friend, who
|
|
doesn't understand RAID, ran fsck on /dev/hda3 while I wasn't
|
|
looking, and now the RAID won't work. What should I do?
|
|
|
|
|
|
A: You should re-examine your concept of ``best friend''.
|
|
In general, fsck should never be run on the individual par-
|
|
titions that compose a RAID array. Assuming that neither of
|
|
the partitions are/were heavily damaged, no data loss has
|
|
occurred, and the RAID-1 device can be recovered as follows:
|
|
|
|
a. make a backup of the file system on /dev/hda3
|
|
|
|
b. dd if=/dev/hda3 of=/dev/hdc3
|
|
|
|
c. mkraid raid1.conf -f --only-superblock
|
|
|
|
This should leave you with a working disk mirror.
|
|
|
|
|
|
|
|
6. Q: Why does the above work as a recovery procedure?
|
|
|
|
A: Because each of the component partitions in a RAID-1 mir-
|
|
ror is a perfectly valid copy of the file system. In a
|
|
pinch, mirroring can be disabled, and one of the partitions
|
|
can be mounted and safely run as an ordinary, non-RAID file
|
|
system. When you are ready to restart using RAID-1, then
|
|
unmount the partition, and follow the above instructions to
|
|
restore the mirror. Note that the above works ONLY for
|
|
RAID-1, and not for any of the other levels.
|
|
It may make you feel more comfortable to reverse the
|
|
direction of the copy above: copy from the disk that was
|
|
untouched to the one that was. Just be sure to fsck the
|
|
final md.
|
|
|
|
|
|
|
|
7. Q: I am confused by the above questions, but am not yet bailing
|
|
out. Is it safe to run fsck /dev/md0 ?
|
|
|
|
|
|
A: Yes, it is safe to run fsck on the md devices. In fact,
|
|
this is the only safe place to run fsck.
|
|
|
|
|
|
|
|
8. Q: If a disk is slowly failing, will it be obvious which one it is?
|
|
I am concerned that it won't be, and this confusion could lead to
|
|
some dangerous decisions by a sysadmin.
|
|
|
|
|
|
A: Once a disk fails, an error code will be returned from
|
|
the low level driver to the RAID driver. The RAID driver
|
|
will mark it as ``bad'' in the RAID superblocks of the
|
|
``good'' disks (so we will later know which mirrors are good
|
|
and which aren't), and continue RAID operation on the
|
|
remaining operational mirrors.
|
|
|
|
|
|
This, of course, assumes that the disk and the low level
|
|
driver can detect a read/write error, and will not silently
|
|
corrupt data, for example. This is true of current drives
|
|
(error detection schemes are being used internally), and is
|
|
the basis of RAID operation.
|
|
|
|
|
|
|
|
9. Q: What about hot-repair?
|
|
|
|
|
|
A: Work is underway to complete ``hot reconstruction''.
|
|
With this feature, one can add several ``spare'' disks to
|
|
the RAID set (be it level 1 or 4/5), and once a disk fails,
|
|
it will be reconstructed on one of the spare disks in run
|
|
time, without ever needing to shut down the array.
|
|
|
|
|
|
However, to use this feature, the spare disk must have been
|
|
declared at boot time, or it must be hot-added, which
|
|
requires the use of special cabinets and connectors that
|
|
allow a disk to be added while the electrical power is on.
|
|
|
|
|
|
As of October 97, there is a beta version of MD that allows:
|
|
|
|
o RAID 1 and 5 reconstruction on spare drives
|
|
|
|
o RAID-5 parity reconstruction after an unclean shutdown
|
|
|
|
o spare disk to be hot-added to an already running RAID 1
|
|
or 4/5 array
|
|
|
|
By default, automatic reconstruction is (Dec 97)
|
|
currently disabled by default, due to the preliminary
|
|
nature of this work. It can be enabled by changing the
|
|
value of SUPPORT_RECONSTRUCTION in include/linux/md.h.
|
|
If spare drives were configured into the array when it
|
|
was created and kernel-based reconstruction is enabled,
|
|
the spare drive will already contain a RAID superblock
|
|
(written by mkraid), and the kernel will reconstruct its
|
|
contents automatically (without needing the usual mdstop,
|
|
replace drive, ckraid, mdrun steps).
|
|
|
|
|
|
If you are not running automatic reconstruction, and have
|
|
not configured a hot-spare disk, the procedure described
|
|
by Gadi Oxman <gadio@netvision.net.il> is recommended:
|
|
|
|
o Currently, once the first disk is removed, the RAID set
|
|
will be running in degraded mode. To restore full
|
|
operation mode, you need to:
|
|
|
|
o stop the array (mdstop /dev/md0)
|
|
|
|
o replace the failed drive
|
|
|
|
o run ckraid raid.conf to reconstruct its contents
|
|
|
|
o run the array again (mdadd, mdrun).
|
|
|
|
At this point, the array will be running with all the
|
|
drives, and again protects against a failure of a single
|
|
drive.
|
|
|
|
Currently, it is not possible to assign single hot-spare
|
|
disk to several arrays. Each array requires it's own
|
|
hot-spare.
|
|
|
|
|
|
|
|
10.
|
|
Q: I would like to have an audible alarm for ``you schmuck, one
|
|
disk in the mirror is down'', so that the novice sysadmin knows
|
|
that there is a problem.
|
|
|
|
|
|
A: The kernel is logging the event with a ``KERN_ALERT''
|
|
priority in syslog. There are several software packages
|
|
that will monitor the syslog files, and beep the PC speaker,
|
|
call a pager, send e-mail, etc. automatically.
|
|
|
|
|
|
|
|
11.
|
|
Q: How do I run RAID-5 in degraded mode (with one disk failed, and
|
|
not yet replaced)?
|
|
|
|
|
|
A: Gadi Oxman <gadio@netvision.net.il> writes: Normally, to
|
|
run a RAID-5 set of n drives you have to:
|
|
|
|
|
|
mdadd /dev/md0 /dev/disk1 ... /dev/disk(n)
|
|
mdrun -p5 /dev/md0
|
|
|
|
|
|
|
|
Even if one of the disks has failed, you still have to mdadd
|
|
it as you would in a normal setup. (?? try using /dev/null
|
|
in place of the failed disk ??? watch out) Then,
|
|
The array will be active in degraded mode with (n - 1)
|
|
drives. If ``mdrun'' fails, the kernel has noticed an error
|
|
(for example, several faulty drives, or an unclean shut-
|
|
down). Use ``dmesg'' to display the kernel error messages
|
|
from ``mdrun''. If the raid-5 set is corrupted due to a
|
|
power loss, rather than a disk crash, one can try to recover
|
|
by creating a new RAID superblock:
|
|
|
|
|
|
mkraid -f --only-superblock raid5.conf
|
|
|
|
|
|
|
|
A RAID array doesn't provide protection against a power
|
|
failure or a kernel crash, and can't guarantee correct
|
|
recovery. Rebuilding the superblock will simply cause the
|
|
system to ignore the condition by marking all the drives as
|
|
``OK'', as if nothing happened.
|
|
|
|
|
|
|
|
12.
|
|
Q: How does RAID-5 work when a disk fails?
|
|
|
|
|
|
A: The typical operating scenario is as follows:
|
|
|
|
o A RAID-5 array is active.
|
|
|
|
o One drive fails while the array is active.
|
|
|
|
o The drive firmware and the low-level Linux
|
|
disk/controller drivers detect the failure and report an
|
|
error code to the MD driver.
|
|
|
|
o The MD driver continues to provide an error-free /dev/md0
|
|
device to the higher levels of the kernel (with a
|
|
performance degradation) by using the remaining
|
|
operational drives.
|
|
|
|
o The sysadmin can umount /dev/md0 and mdstop /dev/md0 as
|
|
usual.
|
|
|
|
o If the failed drive is not replaced, the sysadmin can
|
|
still start the array in degraded mode as usual, by
|
|
running mdadd and mdrun.
|
|
|
|
|
|
|
|
13.
|
|
Q:
|
|
|
|
A:
|
|
|
|
|
|
|
|
14.
|
|
Q: Why is there no question 13?
|
|
|
|
|
|
A: If you are concerned about RAID, High Availability, and
|
|
UPS, then its probably a good idea to be superstitious as
|
|
well. It can't hurt, can it?
|
|
|
|
15.
|
|
Q: I just replaced a failed disk in a RAID-5 array. After
|
|
rebuilding the array, fsck is reporting many, many errors. Is this
|
|
normal?
|
|
|
|
|
|
A: No. And, unless you ran fsck in "verify only; do not
|
|
update" mode, its quite possible that you have corrupted
|
|
your data. Unfortunately, a not-uncommon scenario is one of
|
|
accidentally changing the disk order in a RAID-5 array,
|
|
after replacing a hard drive. Although the RAID superblock
|
|
stores the proper order, not all tools use this information.
|
|
In particular, the current version of ckraid will use the
|
|
information specified with the -f flag (typically, the file
|
|
/etc/raid5.conf) instead of the data in the superblock. If
|
|
the specified order is incorrect, then the replaced disk
|
|
will be reconstructed incorrectly. The symptom of this
|
|
kind of mistake seems to be heavy & numerous fsck errors.
|
|
|
|
|
|
And, in case you are wondering, yes, someone lost all of
|
|
their data by making this mistake. Making a tape backup of
|
|
all data before reconfiguring a RAID array is strongly
|
|
recommended.
|
|
|
|
|
|
|
|
16.
|
|
Q: The QuickStart says that mdstop is just to make sure that the
|
|
disks are sync'ed. Is this REALLY necessary? Isn't unmounting the
|
|
file systems enough?
|
|
|
|
|
|
A: The command mdstop /dev/md0 will:
|
|
|
|
o mark it ''clean''. This allows us to detect unclean
|
|
shutdowns, for example due to a power failure or a kernel
|
|
crash.
|
|
|
|
o sync the array. This is less important after unmounting a
|
|
filesystem, but is important if the /dev/md0 is accessed
|
|
directly rather than through a filesystem (for example,
|
|
by e2fsck).
|
|
|
|
|
|
|
|
5. Troubleshooting Install Problems
|
|
|
|
|
|
1. Q: What is the current best known-stable patch for RAID in the
|
|
2.0.x series kernels?
|
|
|
|
|
|
A: As of 18 Sept 1997, it is "2.0.30 + pre-9 2.0.31 + Werner
|
|
Fink's swapping patch + the alpha RAID patch". As of Novem-
|
|
ber 1997, it is 2.0.31 + ... !?
|
|
|
|
|
|
|
|
2. Q: The RAID patches will not install cleanly for me. What's wrong?
|
|
|
|
A: Make sure that /usr/include/linux is a symbolic link to
|
|
/usr/src/linux/include/linux.
|
|
|
|
Make sure that the new files raid5.c, etc. have been copied
|
|
to their correct locations. Sometimes the patch command
|
|
will not create new files. Try the -f flag on patch.
|
|
|
|
|
|
|
|
3. Q: While compiling raidtools 0.42, compilation stops trying to
|
|
include <pthread.h> but it doesn't exist in my system. How do I
|
|
fix this?
|
|
|
|
|
|
A: raidtools-0.42 requires linuxthreads-0.6 from:
|
|
<ftp://ftp.inria.fr/INRIA/Projects/cristal/Xavier.Leroy>
|
|
Alternately, use glibc v2.0.
|
|
|
|
|
|
|
|
4. Q: I get the message: mdrun -a /dev/md0: Invalid argument
|
|
|
|
|
|
A: Use mkraid to initialize the RAID set prior to the first
|
|
use. mkraid ensures that the RAID array is initially in a
|
|
consistent state by erasing the RAID partitions. In addi-
|
|
tion, mkraid will create the RAID superblocks.
|
|
|
|
|
|
|
|
5. Q: I get the message: mdrun -a /dev/md0: Invalid argument The setup
|
|
was:
|
|
|
|
o raid build as a kernel module
|
|
|
|
o normal install procedure followed ... mdcreate, mdadd, etc.
|
|
|
|
o cat /proc/mdstat shows
|
|
|
|
Personalities :
|
|
read_ahead not set
|
|
md0 : inactive sda1 sdb1 6313482 blocks
|
|
md1 : inactive
|
|
md2 : inactive
|
|
md3 : inactive
|
|
|
|
|
|
|
|
o mdrun -a generates the error message /dev/md0: Invalid argument
|
|
|
|
|
|
|
|
A: Try lsmod (or, alternately, cat /proc/modules) to see if
|
|
the raid modules are loaded. If they are not, you can load
|
|
them explicitly with the modprobe raid1 or modprobe raid5
|
|
command. Alternately, if you are using the autoloader, and
|
|
expected kerneld to load them and it didn't this is probably
|
|
because your loader is missing the info to load the modules.
|
|
Edit /etc/conf.modules and add the following lines:
|
|
|
|
|
|
alias md-personality-3 raid1
|
|
alias md-personality-4 raid5
|
|
|
|
|
|
|
|
6. Q: While doing mdadd -a I get the error: /dev/md0: No such file or
|
|
directory. Indeed, there seems to be no /dev/md0 anywhere. Now
|
|
what do I do?
|
|
|
|
|
|
A: The raid-tools package will create these devices when you
|
|
run make install as root. Alternately, you can do the fol-
|
|
lowing:
|
|
|
|
cd /dev
|
|
./MAKEDEV md
|
|
|
|
|
|
|
|
7. Q: After creating a raid array on /dev/md0, I try to mount it and
|
|
get the following error:
|
|
mount: wrong fs type, bad option, bad superblock on /dev/md0, or
|
|
too many mounted file systems. What's wrong?
|
|
|
|
A: You need to create a file system on /dev/md0 before you
|
|
can mount it. Use mke2fs.
|
|
|
|
|
|
|
|
8. Q: Truxton Fulton wrote:
|
|
|
|
On my Linux 2.0.30 system, while doing a mkraid for a RAID-1
|
|
device, during the clearing of the two individual parti-
|
|
tions, I got "Cannot allocate free page" errors appearing on
|
|
the console, and "Unable to handle kernel paging request at
|
|
virtual address ..." errors in the system log. At this
|
|
time, the system became quite unusable, but it appears to
|
|
recover after a while. The operation appears to have com-
|
|
pleted with no other errors, and I am successfully using my
|
|
RAID-1 device. The errors are disconcerting though. Any
|
|
ideas?
|
|
|
|
|
|
|
|
A: This was a well-known bug in the 2.0.30 kernels. It is
|
|
fixed in the 2.0.31 kernel; alternately, fall back to
|
|
2.0.29.
|
|
|
|
|
|
|
|
9. Q: I'm not able to mdrun a RAID-1, RAID-4 or RAID-5 device. If I
|
|
try to mdrun a mdadd'ed device I get the message ''invalid raid
|
|
superblock magic''.
|
|
|
|
|
|
A: Make sure that you've run the mkraid part of the install
|
|
procedure.
|
|
|
|
|
|
|
|
10.
|
|
Q: When I access /dev/md0, the kernel spits out a lot of errors
|
|
like md0: device not running, giving up ! and I/O error.... I've
|
|
successfully added my devices to the virtual device.
|
|
|
|
A: To be usable, the device must be running. Use mdrun -px
|
|
/dev/md0 where x is l for linear, 0 for RAID-0 or 1 for
|
|
RAID-1, etc.
|
|
|
|
|
|
|
|
11.
|
|
Q: I've created a linear md-dev with 2 devices. cat /proc/mdstat
|
|
shows the total size of the device, but df only shows the size of
|
|
the first physical device.
|
|
|
|
|
|
A: You must mkfs your new md-dev before using it the first
|
|
time, so that the filesystem will cover the whole device.
|
|
|
|
|
|
|
|
12.
|
|
Q: I've set up /etc/mdtab using mdcreate, I've mdadd'ed, mdrun and
|
|
fsck'ed my two /dev/mdX partitions. Everything looks okay before a
|
|
reboot. As soon as I reboot, I get an fsck error on both
|
|
partitions: fsck.ext2: Attempt to read block from filesystem
|
|
resulted in short read while trying too open /dev/md0. Why?! How
|
|
do I fix it?!
|
|
|
|
|
|
A: During the boot process, the RAID partitions must be
|
|
started before they can be fsck'ed. This must be done in
|
|
one of the boot scripts. For some distributions, fsck is
|
|
called from /etc/rc.d/rc.S, for others, it is called from
|
|
/etc/rc.d/rc.sysinit. Change this file to mdadd -ar *before*
|
|
fsck -A is executed. Better yet, it is suggested that
|
|
ckraid be run if mdadd returns with an error. How do do
|
|
this is discussed in greater detail in question 14 of the
|
|
section ''Error Recovery''.
|
|
|
|
|
|
|
|
13.
|
|
Q: I get the message invalid raid superblock magic while trying to
|
|
run an array which consists of partitions which are bigger than
|
|
4GB.
|
|
|
|
|
|
A: This bug is now fixed. (September 97) Make sure you have
|
|
the latest raid code.
|
|
|
|
|
|
|
|
14.
|
|
Q: I get the message Warning: could not write 8 blocks in inode
|
|
table starting at 2097175 while trying to run mke2fs on a partition
|
|
which is larger than 2GB.
|
|
|
|
|
|
A: This seems to be a problem with mke2fs (November 97). A
|
|
temporary work-around is to get the mke2fs code, and add
|
|
#undef HAVE_LLSEEK to e2fsprogs-1.10/lib/ext2fs/llseek.c
|
|
just before the first #ifdef HAVE_LLSEEK and recompile
|
|
mke2fs.
|
|
|
|
|
|
|
|
15.
|
|
Q: ckraid currently isn't able to read /etc/mdtab
|
|
|
|
A: The RAID0/linear configuration file format used in
|
|
/etc/mdtab is obsolete, although it will be supported for a
|
|
while more. The current, up-to-date config files are cur-
|
|
rently named /etc/raid1.conf, etc.
|
|
|
|
|
|
|
|
16.
|
|
Q: The personality modules (raid1.o) are not loaded automatically;
|
|
they have to be manually modprobe'd before mdrun. How can this be
|
|
fixed?
|
|
|
|
|
|
A: To autoload the modules, we can add the following to
|
|
/etc/conf.modules:
|
|
|
|
alias md-personality-3 raid1
|
|
alias md-personality-4 raid5
|
|
|
|
|
|
|
|
17.
|
|
Q: I've mdadd'ed 13 devices, and now I'm trying to mdrun -p5
|
|
/dev/md0 and get the message: /dev/md0: Invalid argument
|
|
|
|
|
|
A: The default configuration for software RAID is 8 real
|
|
devices. Edit linux/md.h, change #define MAX_REAL=8 to a
|
|
larger number, and rebuild the kernel.
|
|
|
|
|
|
|
|
18.
|
|
Q: I can't make md work with partitions on our latest SPARCstation
|
|
5. I suspect that this has something to do with disk-labels.
|
|
|
|
|
|
A: Sun disk-labels sit in the first 1K of a partition. For
|
|
RAID-1, the Sun disk-label is not an issue since ext2fs will
|
|
skip the label on every mirror. For other raid levels (0,
|
|
linear and 4/5), this appears to be a problem; it has not
|
|
yet (Dec 97) been addressed.
|
|
|
|
|
|
|
|
6. Supported Hardware & Software
|
|
|
|
|
|
1. Q: I have SCSI adapter brand XYZ (with or without several
|
|
channels), and disk brand(s) PQR and LMN, will these work with md
|
|
to create a linear/stripped/mirrored personality?
|
|
|
|
|
|
A: Yes! Software RAID will work with any disk controller
|
|
(IDE or SCSI) and any disks. The disks do not have to be
|
|
identical, nor do the controllers. For example, a RAID mir-
|
|
ror can be created with one half the mirror being a SCSI
|
|
disk, and the other an IDE disk. The disks do not even have
|
|
to be the same size. There are no restrictions on the mix-
|
|
ing & matching of disks and controllers.
|
|
|
|
|
|
This is because Software RAID works with disk partitions,
|
|
not with the raw disks themselves. The only recommendation
|
|
is that for RAID levels 1 and 5, the disk partitions that
|
|
are used as part of the same set be the same size. If the
|
|
partitions used to make up the RAID 1 or 5 array are not the
|
|
same size, then the excess space in the larger partitions is
|
|
wasted (not used).
|
|
|
|
|
|
|
|
2. Q: I have a twin channel BT-952, and the box states that it
|
|
supports hardware RAID 0, 1 and 0+1. I have made a RAID set with
|
|
two drives, the card apparently recognizes them when it's doing
|
|
it's BIOS startup routine. I've been reading in the driver source
|
|
code, but found no reference to the hardware RAID support. Anybody
|
|
out there working on that?
|
|
|
|
|
|
A: The Mylex/BusLogic FlashPoint boards with RAIDPlus are
|
|
actually software RAID, not hardware RAID at all. RAIDPlus
|
|
is only supported on Windows 95 and Windows NT, not on Net-
|
|
ware or any of the Unix platforms. Aside from booting and
|
|
configuration, the RAID support is actually in the OS
|
|
drivers.
|
|
|
|
|
|
While in theory Linux support for RAIDPlus is possible, the
|
|
implementation of RAID-0/1/4/5 in the Linux kernel is much
|
|
more flexible and should have superior performance, so
|
|
there's little reason to support RAIDPlus directly.
|
|
|
|
|
|
|
|
3. Q: I want to run RAID with an SMP box. Is RAID SMP-safe?
|
|
|
|
A: "I think so" is the best answer available at the time I
|
|
write this (April 98). A number of users report that they
|
|
have been using RAID with SMP for nearly a year, without
|
|
problems. However, as of April 98 (circa kernel 2.1.9x),
|
|
the following problems have been noted on the mailing list:
|
|
|
|
o Adaptec AIC7xxx SCSI drivers are not SMP safe (General
|
|
note: Adaptec adapters have a long & lengthly history of
|
|
problems & flakiness in general. Although they seem to
|
|
be the most easily available, widespread and cheapest
|
|
SCSI adapters, they should be avoided. After factoring
|
|
for time lost, frustration, and corrupted data, Adaptec's
|
|
will prove to be the costliest mistake you'll ever make.
|
|
That said, if you have SMP problems with 2.1.88, try the
|
|
patch ftp://ftp.bero-
|
|
online.ml.org/pub/linux/aic7xxx-5.0.7-linux21.tar.gz I am
|
|
not sure if this patch has been pulled into later 2.1.x
|
|
kernels. For further info, take a look at the mail
|
|
archives for March 98 at
|
|
http://www.linuxhq.com/lnxlists/linux-raid/lr_9803_01/ As
|
|
usual, due to the rapidly changing nature of the latest
|
|
experimental 2.1.x kernels, the problems described in
|
|
these mailing lists may or may not have been fixed by the
|
|
time your read this. Caveat Emptor. )
|
|
|
|
|
|
|
|
o IO-APIC with RAID-0 on SMP has been reported to crash in
|
|
2.1.90
|
|
|
|
|
|
|
|
7. Modifying an Existing Installation
|
|
|
|
|
|
1. Q: Are linear MD's expandable? Can a new hard-drive/partition be
|
|
added, and the size of the existing file system expanded?
|
|
|
|
|
|
A: Miguel de Icaza <miguel@luthien.nuclecu.unam.mx> writes:
|
|
|
|
I changed the ext2fs code to be aware of multiple-devices
|
|
instead of the regular one device per file system assump-
|
|
tion.
|
|
|
|
|
|
So, when you want to extend a file system, you run a utility
|
|
program that makes the appropriate changes on the new device
|
|
(your extra partition) and then you just tell the system to
|
|
extend the fs using the specified device.
|
|
|
|
|
|
You can extend a file system with new devices at system
|
|
operation time, no need to bring the system down (and
|
|
whenever I get some extra time, you will be able to remove
|
|
devices from the ext2 volume set, again without even having
|
|
to go to single-user mode or any hack like that).
|
|
|
|
|
|
You can get the patch for 2.1.x kernel from my web page:
|
|
|
|
<http://www.nuclecu.unam.mx/~miguel/ext2-volume>
|
|
|
|
|
|
|
|
2. Q: Can I add disks to a RAID-5 array?
|
|
|
|
|
|
A: Currently, (September 1997) no, not without erasing all
|
|
data. A conversion utility to allow this does not yet exist.
|
|
The problem is that the actual structure and layout of a
|
|
RAID-5 array depends on the number of disks in the array.
|
|
|
|
Of course, one can add drives by backing up the array to
|
|
tape, deleting all data, creating a new array, and restoring
|
|
from tape.
|
|
|
|
|
|
|
|
3. Q: What would happen to my RAID1/RAID0 sets if I shift one of the
|
|
drives from being /dev/hdb to /dev/hdc?
|
|
|
|
Because of cabling/case size/stupidity issues, I had to make my
|
|
RAID sets on the same IDE controller (/dev/hda and /dev/hdb). Now
|
|
that I've fixed some stuff, I want to move /dev/hdb to /dev/hdc.
|
|
|
|
What would happen if I just change the /etc/mdtab and
|
|
/etc/raid1.conf files to reflect the new location?
|
|
|
|
A: For RAID-0/linear, one must be careful to specify the
|
|
drives in exactly the same order. Thus, in the above exam-
|
|
ple, if the original config is
|
|
|
|
|
|
|
|
mdadd /dev/md0 /dev/hda /dev/hdb
|
|
|
|
|
|
|
|
Then the new config *must* be
|
|
|
|
|
|
mdadd /dev/md0 /dev/hda /dev/hdc
|
|
|
|
|
|
|
|
For RAID-1/4/5, the drive's ''RAID number'' is stored in its
|
|
RAID superblock, and therefore the order in which the disks
|
|
are specified is not important.
|
|
|
|
RAID-0/linear does not have a superblock due to it's older
|
|
design, and the desire to maintain backwards compatibility
|
|
with this older design.
|
|
|
|
|
|
|
|
4. Q: Can I convert a two-disk RAID-1 mirror to a three-disk RAID-5
|
|
array?
|
|
|
|
|
|
A: Yes. Michael at BizSystems has come up with a clever,
|
|
sneaky way of doing this. However, like virtually all
|
|
manipulations of RAID arrays once they have data on them, it
|
|
is dangerous and prone to human error. Make a backup before
|
|
you start.
|
|
|
|
|
|
|
|
I will make the following assumptions:
|
|
---------------------------------------------
|
|
disks
|
|
original: hda - hdc
|
|
raid1 partitions hda3 - hdc3
|
|
array name /dev/md0
|
|
|
|
new hda - hdc - hdd
|
|
raid5 partitions hda3 - hdc3 - hdd3
|
|
array name: /dev/md1
|
|
|
|
You must substitute the appropriate disk and partition numbers for
|
|
you system configuration. This will hold true for all config file
|
|
examples.
|
|
--------------------------------------------
|
|
DO A BACKUP BEFORE YOU DO ANYTHING
|
|
1) recompile kernel to include both raid1 and raid5
|
|
2) install new kernel and verify that raid personalities are present
|
|
3) disable the redundant partition on the raid 1 array. If this is a
|
|
root mounted partition (mine was) you must be more careful.
|
|
|
|
Reboot the kernel without starting raid devices or boot from rescue
|
|
system ( raid tools must be available )
|
|
|
|
start non-redundant raid1
|
|
mdadd -r -p1 /dev/md0 /dev/hda3
|
|
|
|
4) configure raid5 but with 'funny' config file, note that there is
|
|
no hda3 entry and hdc3 is repeated. This is needed since the
|
|
raid tools don't want you to do this.
|
|
-------------------------------
|
|
# raid-5 configuration
|
|
raiddev /dev/md1
|
|
raid-level 5
|
|
nr-raid-disks 3
|
|
chunk-size 32
|
|
|
|
# Parity placement algorithm
|
|
parity-algorithm left-symmetric
|
|
|
|
# Spare disks for hot reconstruction
|
|
nr-spare-disks 0
|
|
|
|
device /dev/hdc3
|
|
raid-disk 0
|
|
|
|
device /dev/hdc3
|
|
raid-disk 1
|
|
|
|
device /dev/hdd3
|
|
raid-disk 2
|
|
---------------------------------------
|
|
mkraid /etc/raid5.conf
|
|
5) activate the raid5 array in non-redundant mode
|
|
|
|
mdadd -r -p5 -c32k /dev/md1 /dev/hdc3 /dev/hdd3
|
|
|
|
6) make a file system on the array
|
|
|
|
mke2fs -b {blocksize} /dev/md1
|
|
|
|
recommended blocksize by some is 4096 rather than the default 1024.
|
|
this improves the memory utilization for the kernel raid routines and
|
|
matches the blocksize to the page size. I compromised and used 2048
|
|
since I have a relatively high number of small files on my system.
|
|
|
|
7) mount the two raid devices somewhere
|
|
|
|
mount -t ext2 /dev/md0 mnt0
|
|
mount -t ext2 /dev/md1 mnt1
|
|
|
|
8) move the data
|
|
|
|
cp -a mnt0 mnt1
|
|
|
|
9) verify that the data sets are identical
|
|
10) stop both arrays
|
|
11) correct the information for the raid5.conf file
|
|
change /dev/md1 to /dev/md0
|
|
change the first disk to read /dev/hda3
|
|
|
|
12) upgrade the new array to full redundant status
|
|
(THIS DESTROYS REMAINING raid1 INFORMATION)
|
|
|
|
ckraid --fix /etc/raid5.conf
|
|
|
|
|
|
|
|
8. Performance, Tools & General Bone-headed Questions
|
|
|
|
|
|
1. Q: I've created a RAID-0 device on /dev/sda2 and /dev/sda3. The
|
|
device is a lot slower than a single partition. Isn't md a pile of
|
|
junk?
|
|
|
|
A: To have a RAID-0 device running a full speed, you must
|
|
have partitions from different disks. Besides, putting the
|
|
two halves of the mirror on the same disk fails to give you
|
|
any protection whatsoever against disk failure.
|
|
|
|
|
|
|
|
2. Q: What's the use of having RAID-linear when RAID-0 will do the
|
|
same thing, but provide higher performance?
|
|
|
|
A: It's not obvious that RAID-0 will always provide better
|
|
performance; in fact, in some cases, it could make things
|
|
worse. The ext2fs file system scatters files all over a
|
|
partition, and it attempts to keep all of the blocks of a
|
|
file contiguous, basically in an attempt to prevent fragmen-
|
|
tation. Thus, ext2fs behaves "as if" there were a (vari-
|
|
able-sized) stripe per file. If there are several disks
|
|
concatenated into a single RAID-linear, this will result
|
|
files being statistically distributed on each of the disks.
|
|
Thus, at least for ext2fs, RAID-linear will behave a lot
|
|
like RAID-0 with large stripe sizes. Conversely, RAID-0
|
|
with small stripe sizes can cause excessive disk activity
|
|
leading to severely degraded performance if several large
|
|
files are accessed simultaneously.
|
|
|
|
In many cases, RAID-0 can be an obvious win. For example,
|
|
imagine a large database file. Since ext2fs attempts to
|
|
cluster together all of the blocks of a file, chances are
|
|
good that it will end up on only one drive if RAID-linear is
|
|
used, but will get chopped into lots of stripes if RAID-0 is
|
|
used. Now imagine a number of (kernel) threads all trying
|
|
to random access to this database. Under RAID-linear, all
|
|
accesses would go to one disk, which would not be as
|
|
efficient as the parallel accesses that RAID-0 entails.
|
|
|
|
|
|
|
|
3. Q: How does RAID-0 handle a situation where the different stripe
|
|
partitions are different sizes? Are the stripes uniformly
|
|
distributed?
|
|
|
|
|
|
A: To understand this, lets look at an example with three
|
|
partitions; one that is 50MB, one 90MB and one 125MB.
|
|
|
|
Lets call D0 the 50MB disk, D1 the 90MB disk and D2 the
|
|
125MB disk. When you start the device, the driver calcu-
|
|
lates 'strip zones'. In this case, it finds 3 zones,
|
|
defined like this:
|
|
|
|
|
|
Z0 : (D0/D1/D2) 3 x 50 = 150MB total in this zone
|
|
Z1 : (D1/D2) 2 x 40 = 80MB total in this zone
|
|
Z2 : (D2) 125-50-40 = 35MB total in this zone.
|
|
|
|
|
|
|
|
You can see that the total size of the zones is the size of
|
|
the virtual device, but, depending on the zone, the striping
|
|
is different. Z2 is rather inefficient, since there's only
|
|
one disk.
|
|
|
|
Since ext2fs and most other Unix file systems distribute
|
|
files all over the disk, you have a 35/265 = 13% chance
|
|
that a fill will end up on Z2, and not get any of the bene-
|
|
fits of striping.
|
|
|
|
(DOS tries to fill a disk from beginning to end, and thus,
|
|
the oldest files would end up on Z0. However, this strategy
|
|
leads to severe filesystem fragmentation, which is why no
|
|
one besides DOS does it this way.)
|
|
|
|
|
|
|
|
4. Q: I have some Brand X hard disks and a Brand Y controller. and am
|
|
considering using md. Does it significantly increase the
|
|
throughput? Is the performance really noticeable?
|
|
|
|
|
|
A: The answer depends on the configuration that you use.
|
|
|
|
|
|
Linux MD RAID-0 and RAID-linear performance:
|
|
If the system is heavily loaded with lots of I/O,
|
|
statistically, some of it will go to one disk, and
|
|
some to the others. Thus, performance will improve
|
|
over a single large disk. The actual improvement
|
|
depends a lot on the actual data, stripe sizes, and
|
|
other factors. In a system with low I/O usage, the
|
|
performance is equal to that of a single disk.
|
|
|
|
|
|
|
|
Linux MD RAID-1 (mirroring) read performance:
|
|
MD implements read balancing. That is, the RAID-1
|
|
code will alternate between each of the (two or more)
|
|
disks in the mirror, making alternate reads to each.
|
|
In a low-I/O situation, this won't change performance
|
|
at all: you will have to wait for one disk to complete
|
|
the read. But, with two disks in a high-I/O
|
|
environment, this could as much as double the read
|
|
performance, since reads can be issued to each of the
|
|
disks in parallel. For N disks in the mirror, this
|
|
could improve performance N-fold.
|
|
|
|
|
|
Linux MD RAID-1 (mirroring) write performance:
|
|
Must wait for the write to occur to all of the disks
|
|
in the mirror. This is because a copy of the data
|
|
must be written to each of the disks in the mirror.
|
|
Thus, performance will be roughly equal to the write
|
|
performance to a single disk.
|
|
|
|
|
|
Linux MD RAID-4/5 read performance:
|
|
Statistically, a given block can be on any one of a
|
|
number of disk drives, and thus RAID-4/5 read
|
|
performance is a lot like that for RAID-0. It will
|
|
depend on the data, the stripe size, and the
|
|
application. It will not be as good as the read
|
|
performance of a mirrored array.
|
|
|
|
|
|
Linux MD RAID-4/5 write performance:
|
|
This will in general be considerably slower than that
|
|
for a single disk. This is because the parity must be
|
|
written out to one drive as well as the data to
|
|
another. However, in order to compute the new parity,
|
|
the old parity and the old data must be read first.
|
|
The old data, new data and old parity must all be
|
|
XOR'ed together to determine the new parity: this
|
|
requires considerable CPU cycles in addition to the
|
|
numerous disk accesses.
|
|
|
|
|
|
|
|
5. Q: What RAID configuration should I use for optimal performance?
|
|
|
|
A: Is the goal to maximize throughput, or to minimize
|
|
latency? There is no easy answer, as there are many factors
|
|
that affect performance:
|
|
|
|
|
|
o operating system - will one process/thread, or many be
|
|
performing disk access?
|
|
|
|
o application - is it accessing data in a sequential
|
|
fashion, or random access?
|
|
|
|
o file system - clusters files or spreads them out
|
|
(the ext2fs clusters together the blocks of a file, and
|
|
spreads out files)
|
|
|
|
o disk driver - number of blocks to read ahead (this
|
|
is a tunable parameter)
|
|
|
|
o CEC hardware - one drive controller, or many?
|
|
|
|
o hd controller - able to queue multiple requests or
|
|
not? Does it provide a cache?
|
|
|
|
o hard drive - buffer cache memory size -- is it big
|
|
enough to handle the write sizes and rate you want?
|
|
o physical platters - blocks per cylinder -- accessing
|
|
blocks on different cylinders will lead to seeks.
|
|
|
|
|
|
|
|
6. Q: What is the optimal RAID-5 configuration for performance?
|
|
|
|
A: Since RAID-5 experiences an I/O load that is equally dis-
|
|
tributed across several drives, the best performance will be
|
|
obtained when the RAID set is balanced by using identical
|
|
drives, identical controllers, and the same (low) number of
|
|
drives on each controller.
|
|
|
|
Note, however, that using identical components will raise
|
|
the probability of multiple simultaneous failures, for exam-
|
|
ple due to a sudden jolt or drop, overheating, or a power
|
|
surge during an electrical storm. Mixing brands and models
|
|
helps reduce this risk.
|
|
|
|
|
|
|
|
7. Q: What is the optimal block size for a RAID-4/5 array?
|
|
|
|
|
|
A: When using the current (November 1997) RAID-4/5 implemen-
|
|
tation, it is strongly recommended that the file system be
|
|
created with mke2fs -b 4096 instead of the default 1024 byte
|
|
filesystem block size.
|
|
|
|
|
|
This is because the current RAID-5 implementation allocates
|
|
one 4K memory page per disk block; if a disk block were just
|
|
1K in size, then 75% of the memory which RAID-5 is
|
|
allocating for pending I/O would not be used. If the disk
|
|
block size matches the memory page size, then the driver can
|
|
(potentially) use all of the page. Thus, for a filesystem
|
|
with a 4096 block size as opposed to a 1024 byte block size,
|
|
the RAID driver will potentially queue 4 times as much
|
|
pending I/O to the low level drivers without allocating
|
|
additional memory.
|
|
|
|
|
|
Note: the above remarks do NOT apply to Software
|
|
RAID-0/1/linear driver.
|
|
|
|
|
|
Note: the statements about 4K memory page size apply to the
|
|
Intel x86 architecture. The page size on Alpha, Sparc, and
|
|
other CPUS are different; I believe they're 8K on
|
|
Alpha/Sparc (????). Adjust the above figures accordingly.
|
|
|
|
|
|
Note: if your file system has a lot of small files (files
|
|
less than 10KBytes in size), a considerable fraction of the
|
|
disk space might be wasted. This is because the file system
|
|
allocates disk space in multiples of the block size.
|
|
Allocating large blocks for small files clearly results in a
|
|
waste of disk space: thus, you may want to stick to small
|
|
block sizes, get a larger effective storage capacity, and
|
|
not worry about the "wasted" memory due to the block-
|
|
size/page-size mismatch.
|
|
|
|
|
|
Note: most ''typical'' systems do not have that many small
|
|
files. That is, although there might be thousands of small
|
|
files, this would lead to only some 10 to 100MB wasted
|
|
space, which is probably an acceptable tradeoff for
|
|
performance on a multi-gigabyte disk.
|
|
|
|
However, for news servers, there might be tens or hundreds
|
|
of thousands of small files. In such cases, the smaller
|
|
block size, and thus the improved storage capacity, may be
|
|
more important than the more efficient I/O scheduling.
|
|
|
|
|
|
Note: there exists an experimental file system for Linux
|
|
which packs small files and file chunks onto a single block.
|
|
It apparently has some very positive performance
|
|
implications when the average file size is much smaller than
|
|
the block size.
|
|
|
|
|
|
Note: Future versions may implement schemes that obsolete
|
|
the above discussion. However, this is difficult to
|
|
implement, since dynamic run-time allocation can lead to
|
|
dead-locks; the current implementation performs a static
|
|
pre-allocation.
|
|
|
|
|
|
|
|
8. Q: How does the chunk size (stripe size) influence the speed of my
|
|
RAID-0, RAID-4 or RAID-5 device?
|
|
|
|
|
|
A: The chunk size is the amount of data contiguous on the
|
|
virtual device that is also contiguous on the physical
|
|
device. In this HOWTO, "chunk" and "stripe" refer to the
|
|
same thing: what is commonly called the "stripe" in other
|
|
RAID documentation is called the "chunk" in the MD man
|
|
pages. Stripes or chunks apply only to RAID 0, 4 and 5,
|
|
since stripes are not used in mirroring (RAID-1) and simple
|
|
concatenation (RAID-linear). The stripe size affects both
|
|
read and write latency (delay), throughput (bandwidth), and
|
|
contention between independent operations (ability to simul-
|
|
taneously service overlapping I/O requests).
|
|
|
|
Assuming the use of the ext2fs file system, and the current
|
|
kernel policies about read-ahead, large stripe sizes are
|
|
almost always better than small stripe sizes, and stripe
|
|
sizes from about a fourth to a full disk cylinder in size
|
|
may be best. To understand this claim, let us consider the
|
|
effects of large stripes on small files, and small stripes
|
|
on large files. The stripe size does not affect the read
|
|
performance of small files: For an array of N drives, the
|
|
file has a 1/N probability of being entirely within one
|
|
stripe on any one of the drives. Thus, both the read
|
|
latency and bandwidth will be comparable to that of a single
|
|
drive. Assuming that the small files are statistically well
|
|
distributed around the filesystem, (and, with the ext2fs
|
|
file system, they should be), roughly N times more
|
|
overlapping, concurrent reads should be possible without
|
|
significant collision between them. Conversely, if very
|
|
small stripes are used, and a large file is read
|
|
sequentially, then a read will issued to all of the disks in
|
|
the array. For a the read of a single large file, the
|
|
latency will almost double, as the probability of a block
|
|
being 3/4'ths of a revolution or farther away will increase.
|
|
Note, however, the trade-off: the bandwidth could improve
|
|
almost N-fold for reading a single, large file, as N drives
|
|
can be reading simultaneously (that is, if read-ahead is
|
|
used so that all of the disks are kept active). But there
|
|
is another, counter-acting trade-off: if all of the drives
|
|
are already busy reading one file, then attempting to read a
|
|
second or third file at the same time will cause significant
|
|
contention, ruining performance as the disk ladder
|
|
algorithms lead to seeks all over the platter. Thus, large
|
|
stripes will almost always lead to the best performance. The
|
|
sole exception is the case where one is streaming a single,
|
|
large file at a time, and one requires the top possible
|
|
bandwidth, and one is also using a good read-ahead
|
|
algorithm, in which case small stripes are desired.
|
|
|
|
|
|
Note that this HOWTO previously recommended small stripe
|
|
sizes for news spools or other systems with lots of small
|
|
files. This was bad advice, and here's why: news spools
|
|
contain not only many small files, but also large summary
|
|
files, as well as large directories. If the summary file is
|
|
larger than the stripe size, reading it will cause many
|
|
disks to be accessed, slowing things down as each disk
|
|
performs a seek. Similarly, the current ext2fs file system
|
|
searches directories in a linear, sequential fashion. Thus,
|
|
to find a given file or inode, on average half of the
|
|
directory will be read. If this directory is spread across
|
|
several stripes (several disks), the directory read (e.g.
|
|
due to the ls command) could get very slow. Thanks to Steven
|
|
A. Reisman <sar@pressenter.com> for this correction. Steve
|
|
also adds:
|
|
|
|
I found that using a 256k stripe gives much better perfor-
|
|
mance. I suspect that the optimum size would be the size of
|
|
a disk cylinder (or maybe the size of the disk drive's sec-
|
|
tor cache). However, disks nowadays have recording zones
|
|
with different sector counts (and sector caches vary among
|
|
different disk models). There's no way to guarantee stripes
|
|
won't cross a cylinder boundary.
|
|
|
|
|
|
|
|
The tools accept the stripe size specified in KBytes. You'll want to
|
|
specify a multiple of if the page size for your CPU (4KB on the x86).
|
|
|
|
|
|
|
|
9. Q: What is the correct stride factor to use when creating the
|
|
ext2fs file system on the RAID partition? By stride, I mean the -R
|
|
flag on the mke2fs command:
|
|
|
|
mke2fs -b 4096 -R stride=nnn ...
|
|
|
|
|
|
|
|
What should the value of nnn be?
|
|
|
|
A: The -R stride flag is used to tell the file system about
|
|
the size of the RAID stripes. Since only RAID-0,4 and 5 use
|
|
stripes, and RAID-1 (mirroring) and RAID-linear do not, this
|
|
flag is applicable only for RAID-0,4,5.
|
|
|
|
Knowledge of the size of a stripe allows mke2fs to allocate
|
|
the block and inode bitmaps so that they don't all end up on
|
|
the same physical drive. An unknown contributor wrote:
|
|
|
|
I noticed last spring that one drive in a pair always had a
|
|
larger I/O count, and tracked it down to the these meta-data
|
|
blocks. Ted added the -R stride= option in response to my
|
|
explanation and request for a workaround.
|
|
|
|
|
|
For a 4KB block file system, with stripe size 256KB, one would use -R
|
|
stride=64.
|
|
|
|
If you don't trust the -R flag, you can get a similar effect in a
|
|
different way. Steven A. Reisman <sar@pressenter.com> writes:
|
|
|
|
Another consideration is the filesystem used on the RAID-0
|
|
device. The ext2 filesystem allocates 8192 blocks per
|
|
group. Each group has its own set of inodes. If there are
|
|
2, 4 or 8 drives, these inodes cluster on the first disk.
|
|
I've distributed the inodes across all drives by telling
|
|
mke2fs to allocate only 7932 blocks per group.
|
|
|
|
|
|
Some mke2fs pages do not describe the [-g blocks-per-group] flag used
|
|
in this operation.
|
|
|
|
|
|
|
|
10.
|
|
Q: Where can I put the md commands in the startup scripts, so that
|
|
everything will start automatically at boot time?
|
|
|
|
|
|
A: Rod Wilkens <rwilkens@border.net> writes:
|
|
|
|
What I did is put ``mdadd -ar'' in the
|
|
``/etc/rc.d/rc.sysinit'' right after the kernel loads the
|
|
modules, and before the ``fsck'' disk check. This way, you
|
|
can put the ``/dev/md?'' device in the ``/etc/fstab''. Then
|
|
I put the ``mdstop -a'' right after the ``umount -a''
|
|
unmounting the disks, in the ``/etc/rc.d/init.d/halt'' file.
|
|
|
|
|
|
For raid-5, you will want to look at the return code for mdadd, and if
|
|
it failed, do a
|
|
|
|
|
|
ckraid --fix /etc/raid5.conf
|
|
|
|
|
|
|
|
to repair any damage.
|
|
|
|
|
|
|
|
11.
|
|
Q: I was wondering if it's possible to setup striping with more
|
|
than 2 devices in md0? This is for a news server, and I have 9
|
|
drives... Needless to say I need much more than two. Is this
|
|
possible?
|
|
|
|
|
|
A: Yes. (describe how to do this)
|
|
|
|
|
|
|
|
12.
|
|
Q: When is Software RAID superior to Hardware RAID?
|
|
|
|
|
|
A: Normally, Hardware RAID is considered superior to Soft-
|
|
ware RAID, because hardware controllers often have a large
|
|
cache, and can do a better job of scheduling operations in
|
|
parallel. However, integrated Software RAID can (and does)
|
|
gain certain advantages from being close to the operating
|
|
system.
|
|
|
|
|
|
For example, ... ummm. Opaque description of caching of
|
|
reconstructed blocks in buffer cache elided ...
|
|
|
|
|
|
On a dual PPro SMP system, it has been reported that
|
|
Software-RAID performance exceeds the performance of a well-
|
|
known hardware-RAID board vendor by a factor of 2 to 5.
|
|
|
|
|
|
Software RAID is also a very interesting option for high-
|
|
availability redundant server systems. In such a
|
|
configuration, two CPU's are attached to one set or SCSI
|
|
disks. If one server crashes or fails to respond, then the
|
|
other server can mdadd, mdrun and mount the software RAID
|
|
array, and take over operations. This sort of dual-ended
|
|
operation is not always possible with many hardware RAID
|
|
controllers, because of the state configuration that the
|
|
hardware controllers maintain.
|
|
|
|
|
|
|
|
13.
|
|
Q: If I upgrade my version of raidtools, will it have trouble
|
|
manipulating older raid arrays? In short, should I recreate my
|
|
RAID arrays when upgrading the raid utilities?
|
|
|
|
|
|
A: No, not unless the major version number changes. An MD
|
|
version x.y.z consists of three sub-versions:
|
|
|
|
x: Major version.
|
|
y: Minor version.
|
|
z: Patchlevel version.
|
|
|
|
|
|
|
|
Version x1.y1.z1 of the RAID driver supports a RAID array
|
|
with version x2.y2.z2 in case (x1 == x2) and (y1 >= y2).
|
|
|
|
Different patchlevel (z) versions for the same (x.y) version
|
|
are designed to be mostly compatible.
|
|
|
|
|
|
The minor version number is increased whenever the RAID
|
|
array layout is changed in a way which is incompatible with
|
|
older versions of the driver. New versions of the driver
|
|
will maintain compatibility with older RAID arrays.
|
|
|
|
The major version number will be increased if it will no
|
|
longer make sense to support old RAID arrays in the new
|
|
kernel code.
|
|
|
|
|
|
For RAID-1, it's not likely that the disk layout nor the
|
|
superblock structure will change anytime soon. Most all Any
|
|
optimization and new features (reconstruction, multithreaded
|
|
tools, hot-plug, etc.) doesn't affect the physical layout.
|
|
14.
|
|
Q: The command mdstop /dev/md0 says that the device is busy.
|
|
|
|
|
|
A: There's a process that has a file open on /dev/md0, or
|
|
/dev/md0 is still mounted. Terminate the process or umount
|
|
/dev/md0.
|
|
|
|
|
|
|
|
15.
|
|
Q: Are there performance tools?
|
|
|
|
A: There is also a new utility called iotrace in the
|
|
linux/iotrace directory. It reads /proc/io-trace and analy-
|
|
ses/plots it's output. If you feel your system's block IO
|
|
performance is too low, just look at the iotrace output.
|
|
|
|
|
|
|
|
16.
|
|
Q: I was reading the RAID source, and saw the value SPEED_LIMIT
|
|
defined as 1024K/sec. What does this mean? Does this limit
|
|
performance?
|
|
|
|
|
|
A: SPEED_LIMIT is used to limit RAID reconstruction speed
|
|
during automatic reconstruction. Basically, automatic
|
|
reconstruction allows you to e2fsck and mount immediately
|
|
after an unclean shutdown, without first running ckraid.
|
|
Automatic reconstruction is also used after a failed hard
|
|
drive has been replaced.
|
|
|
|
|
|
In order to avoid overwhelming the system while
|
|
reconstruction is occurring, the reconstruction thread
|
|
monitors the reconstruction speed and slows it down if its
|
|
too fast. The 1M/sec limit was arbitrarily chosen as a
|
|
reasonable rate which allows the reconstruction to finish
|
|
reasonably rapidly, while creating only a light load on the
|
|
system so that other processes are not interfered with.
|
|
|
|
|
|
|
|
17.
|
|
Q: What about ''spindle synchronization'' or ''disk
|
|
synchronization''?
|
|
|
|
A: Spindle synchronization is used to keep multiple hard
|
|
drives spinning at exactly the same speed, so that their
|
|
disk platters are always perfectly aligned. This is used by
|
|
some hardware controllers to better organize disk writes.
|
|
However, for software RAID, this information is not used,
|
|
and spindle synchronization might even hurt performance.
|
|
|
|
|
|
|
|
18.
|
|
Q: How can I set up swap spaces using raid 0? Wouldn't striped
|
|
swap ares over 4+ drives be really fast?
|
|
|
|
A: Leonard N. Zubkoff replies: It is really fast, but you
|
|
don't need to use MD to get striped swap. The kernel auto-
|
|
matically stripes across equal priority swap spaces. For
|
|
example, the following entries from /etc/fstab stripe swap
|
|
space across five drives in three groups:
|
|
/dev/sdg1 swap swap pri=3
|
|
/dev/sdk1 swap swap pri=3
|
|
/dev/sdd1 swap swap pri=3
|
|
/dev/sdh1 swap swap pri=3
|
|
/dev/sdl1 swap swap pri=3
|
|
/dev/sdg2 swap swap pri=2
|
|
/dev/sdk2 swap swap pri=2
|
|
/dev/sdd2 swap swap pri=2
|
|
/dev/sdh2 swap swap pri=2
|
|
/dev/sdl2 swap swap pri=2
|
|
/dev/sdg3 swap swap pri=1
|
|
/dev/sdk3 swap swap pri=1
|
|
/dev/sdd3 swap swap pri=1
|
|
/dev/sdh3 swap swap pri=1
|
|
/dev/sdl3 swap swap pri=1
|
|
|
|
|
|
|
|
19.
|
|
Q: I want to maximize performance. Should I use multiple
|
|
controllers?
|
|
|
|
A: In many cases, the answer is yes. Using several con-
|
|
trollers to perform disk access in parallel will improve
|
|
performance. However, the actual improvement depends on
|
|
your actual configuration. For example, it has been
|
|
reported (Vaughan Pratt, January 98) that a single 4.3GB
|
|
Cheetah attached to an Adaptec 2940UW can achieve a rate of
|
|
14MB/sec (without using RAID). Installing two disks on one
|
|
controller, and using a RAID-0 configuration results in a
|
|
measured performance of 27 MB/sec.
|
|
|
|
|
|
Note that the 2940UW controller is an "Ultra-Wide" SCSI
|
|
controller, capable of a theoretical burst rate of 40MB/sec,
|
|
and so the above measurements are not surprising. However,
|
|
a slower controller attached to two fast disks would be the
|
|
bottleneck. Note also, that most out-board SCSI enclosures
|
|
(e.g. the kind with hot-pluggable trays) cannot be run at
|
|
the 40MB/sec rate, due to cabling and electrical noise
|
|
problems.
|
|
|
|
|
|
If you are designing a multiple controller system, remember
|
|
that most disks and controllers typically run at 70-85% of
|
|
their rated max speeds.
|
|
|
|
|
|
Note also that using one controller per disk can reduce the
|
|
likelihood of system outage due to a controller or cable
|
|
failure (In theory -- only if the device driver for the
|
|
controller can gracefully handle a broken controller. Not
|
|
all SCSI device drivers seem to be able to handle such a
|
|
situation without panicking or otherwise locking up).
|
|
|
|
|
|
9. High Availability RAID
|
|
|
|
|
|
1. Q: RAID can help protect me against data loss. But how can I also
|
|
ensure that the system is up as long as possible, and not prone to
|
|
breakdown? Ideally, I want a system that is up 24 hours a day, 7
|
|
days a week, 365 days a year.
|
|
|
|
A: High-Availability is difficult and expensive. The harder
|
|
you try to make a system be fault tolerant, the harder and
|
|
more expensive it gets. The following hints, tips, ideas
|
|
and unsubstantiated rumors may help you with this quest.
|
|
|
|
o IDE disks can fail in such a way that the failed disk on
|
|
an IDE ribbon can also prevent the good disk on the same
|
|
ribbon from responding, thus making it look as if two
|
|
disks have failed. Since RAID does not protect against
|
|
two-disk failures, one should either put only one disk on
|
|
an IDE cable, or if there are two disks, they should
|
|
belong to different RAID sets.
|
|
|
|
o SCSI disks can fail in such a way that the failed disk on
|
|
a SCSI chain can prevent any device on the chain from
|
|
being accessed. The failure mode involves a short of the
|
|
common (shared) device ready pin; since this pin is
|
|
shared, no arbitration can occur until the short is
|
|
removed. Thus, no two disks on the same SCSI chain
|
|
should belong to the same RAID array.
|
|
|
|
o Similar remarks apply to the disk controllers. Don't
|
|
load up the channels on one controller; use multiple
|
|
controllers.
|
|
|
|
o Don't use the same brand or model number for all of the
|
|
disks. It is not uncommon for severe electrical storms
|
|
to take out two or more disks. (Yes, we all use surge
|
|
suppressors, but these are not perfect either). Heat &
|
|
poor ventilation of the disk enclosure are other disk
|
|
killers. Cheap disks often run hot. Using different
|
|
brands of disk & controller decreases the likelihood that
|
|
whatever took out one disk (heat, physical shock,
|
|
vibration, electrical surge) will also damage the others
|
|
on the same date.
|
|
|
|
o To guard against controller or CPU failure, it should be
|
|
possible to build a SCSI disk enclosure that is "twin-
|
|
tailed": i.e. is connected to two computers. One
|
|
computer will mount the file-systems read-write, while
|
|
the second computer will mount them read-only, and act as
|
|
a hot spare. When the hot-spare is able to determine
|
|
that the master has failed (e.g. through a watchdog), it
|
|
will cut the power to the master (to make sure that it's
|
|
really off), and then fsck & remount read-write. If
|
|
anyone gets this working, let me know.
|
|
|
|
o Always use an UPS, and perform clean shutdowns. Although
|
|
an unclean shutdown may not damage the disks, running
|
|
ckraid on even small-ish arrays is painfully slow. You
|
|
want to avoid running ckraid as much as possible. Or you
|
|
can hack on the kernel and get the hot-reconstruction
|
|
code debugged ...
|
|
|
|
o SCSI cables are well-known to be very temperamental
|
|
creatures, and prone to cause all sorts of problems. Use
|
|
the highest quality cabling that you can find for sale.
|
|
Use e.g. bubble-wrap to make sure that ribbon cables to
|
|
not get too close to one another and cross-talk.
|
|
Rigorously observe cable-length restrictions.
|
|
|
|
o Take a look at SSI (Serial Storage Architecture).
|
|
Although it is rather expensive, it is rumored to be less
|
|
prone to the failure modes that SCSI exhibits.
|
|
|
|
|
|
o Enjoy yourself, its later than you think.
|
|
|
|
|
|
10. Questions Waiting for Answers
|
|
|
|
|
|
1. Q: If, for cost reasons, I try to mirror a slow disk with a fast
|
|
disk, is the S/W smart enough to balance the reads accordingly or
|
|
will it all slow down to the speed of the slowest?
|
|
|
|
|
|
2. Q: For testing the raw disk thru put... is there a character
|
|
device for raw read/raw writes instead of /dev/sdaxx that we can
|
|
use to measure performance on the raid drives?? is there a GUI
|
|
based tool to use to watch the disk thru-put??
|
|
|
|
|
|
11. Wish List of Enhancements to MD and Related Software
|
|
|
|
Bradley Ward Allen <ulmo@Q.Net> wrote:
|
|
|
|
Ideas include:
|
|
|
|
o Boot-up parameters to tell the kernel which devices are
|
|
to be MD devices (no more ``mdadd'')
|
|
|
|
o Making MD transparent to ``mount''/``umount'' such that
|
|
there is no ``mdrun'' and ``mdstop''
|
|
|
|
o Integrating ``ckraid'' entirely into the kernel, and
|
|
letting it run as needed
|
|
|
|
(So far, all I've done is suggest getting rid of the
|
|
tools and putting them into the kernel; that's how I feel
|
|
about it, this is a filesystem, not a toy.)
|
|
|
|
o Deal with arrays that can easily survive N disks going
|
|
out simultaneously or at separate moments, where N is a
|
|
whole number > 0 settable by the administrator
|
|
|
|
o Handle kernel freezes, power outages, and other abrupt
|
|
shutdowns better
|
|
|
|
o Don't disable a whole disk if only parts of it have
|
|
failed, e.g., if the sector errors are confined to less
|
|
than 50% of access over the attempts of 20 dissimilar
|
|
requests, then it continues just ignoring those sectors
|
|
of that particular disk.
|
|
|
|
o Bad sectors:
|
|
|
|
o A mechanism for saving which sectors are bad, someplace
|
|
onto the disk.
|
|
|
|
o If there is a generalized mechanism for marking degraded
|
|
bad blocks that upper filesystem levels can recognize,
|
|
use that. Program it if not.
|
|
|
|
o Perhaps alternatively a mechanism for telling the upper
|
|
layer that the size of the disk got smaller, even
|
|
arranging for the upper layer to move out stuff from the
|
|
areas being eliminated. This would help with a degraded
|
|
blocks as well.
|
|
|
|
o Failing the above ideas, keeping a small (admin settable)
|
|
amount of space aside for bad blocks (distributed evenly
|
|
across disk?), and using them (nearby if possible)
|
|
instead of the bad blocks when it does happen. Of
|
|
course, this is inefficient. Furthermore, the kernel
|
|
ought to log every time the RAID array starts each bad
|
|
sector and what is being done about it with a ``crit''
|
|
level warning, just to get the administrator to realize
|
|
that his disk has a piece of dust burrowing into it (or a
|
|
head with platter sickness).
|
|
|
|
o Software-switchable disks:
|
|
|
|
``disable this disk''
|
|
would block until kernel has completed making sure
|
|
there is no data on the disk being shut down that is
|
|
needed (e.g., to complete an XOR/ECC/other error
|
|
correction), then release the disk from use (so it
|
|
could be removed, etc.);
|
|
|
|
``enable this disk''
|
|
would mkraid a new disk if appropriate and then start
|
|
using it for ECC/whatever operations, enlarging the
|
|
RAID5 array as it goes;
|
|
|
|
``resize array''
|
|
would respecify the total number of disks and the
|
|
number of redundant disks, and the result would often
|
|
be to resize the size of the array; where no data loss
|
|
would result, doing this as needed would be nice, but
|
|
I have a hard time figuring out how it would do that;
|
|
in any case, a mode where it would block (for possibly
|
|
hours (kernel ought to log something every ten seconds
|
|
if so)) would be necessary;
|
|
|
|
``enable this disk while saving data''
|
|
which would save the data on a disk as-is and move it
|
|
to the RAID5 system as needed, so that a horrific save
|
|
and restore would not have to happen every time
|
|
someone brings up a RAID5 system (instead, it may be
|
|
simpler to only save one partition instead of two, it
|
|
might fit onto the first as a gzip'd file even);
|
|
finally,
|
|
|
|
``re-enable disk''
|
|
would be an operator's hint to the OS to try out a
|
|
previously failed disk (it would simply call disable
|
|
then enable, I suppose).
|
|
|
|
|
|
Other ideas off the net:
|
|
|
|
|
|
o finalrd analog to initrd, to simplify root raid.
|
|
|
|
o a read-only raid mode, to simplify the above
|
|
|
|
o Mark the RAID set as clean whenever there are no "half
|
|
writes" done. -- That is, whenever there are no write
|
|
transactions that were committed on one disk but still
|
|
unfinished on another disk.
|
|
|
|
Add a "write inactivity" timeout (to avoid frequent seeks
|
|
to the RAID superblock when the RAID set is relatively
|
|
busy).
|
|
|
|
|
|
|