<H1><A NAME="htoc5">Chapter 2</A> Introduction</H1>
|
|
The Antares 5070 is a high performance, versatile, yet relatively inexpensive
|
|
host based RAID controller. Its embedded operating system (K9 kernel) is modelled
|
|
on the Plan 9 operating system whose design is discussed in several papers from
|
|
AT&T (see the "Further Reading" section). K9 is a kernel
|
|
targeted at embedded controllers of small to medium complexity (e.g. ISDN-ethernet
|
|
bridges, RAID controllers, etc). It supports multiple lightweight processes
|
|
(i.e. without memory management) on a single CPU with a non-preemptive scheduler.
|
|
Device driver architecture is based on Plan 9 (and Unix SVR4) streams. Concurrency
|
|
control mechanisms include semaphores and signals. <BR>
|
|
The 5070 has three single ended ultra 1 SCSI channels and two onboard serial
|
|
interfaces one of which provides command line access via a connected serial
|
|
terminal or modem. The other is used to upgrade the firmware. The command line
|
|
is robust, implementing many of the essential Unix commands (e.g. dd, ls, cat,
|
|
etc.) and a scaled down Bourne shell for scripting. The Unix command set is
|
|
augmented with RAID specific configuration commands and scripts. In addition
|
|
to the command line interface an ASCII text based GUI is provided to permit
|
|
easy configuration of level 0, 1, 3, 4, and 5 RAIDs. <BR>
|
|
<BR>
|
|
<A NAME="toc4"></A>
|
|
<H2><A NAME="htoc6">2.1</A> 5070 features5070 Main Features</H2>
|
|
<UL><LI>
|
|
RAID levels 0, 1, 3, 4, and 5 are supported.
|
|
<LI>Text based GUI for easy configuration for all supported RAID levels.
|
|
<LI>A Multidisk RAID volume appears as an individual SCSI drive to the operating
|
|
system and can be managed with the standard utilities (fdisk, mkfs, fsck,etc.).
|
|
RAID Volumes may be assigned to different SCSI IDs or the same SCSI IDs but
|
|
different LUNs.
|
|
<LI>No special RAID drivers required for the host operating system.
|
|
<LI>Multiple RAID volumes of different levels can be mixed among the drives forming
|
|
the physical plant. For example in a hypothetical drive plant consisting of
|
|
9 drives:
|
|
<UL><LI>
|
|
2 drives form a level 3 RAID assigned to SCSI ID 5, LUN 0
|
|
<LI>2 drives form a level 0 RAID assigned to SCSI ID 5, LUN 1
|
|
<LI>5 drives form a level 5 RAID assigned to SCSI ID 6, LUN 0
|
|
</UL>
|
|
<LI>Three single ended SCSI channels which can accommodate 6 drives each (18 drives
|
|
total).
|
|
<LI>Two serial interfaces. The first permits configuration/control/monitoring of
|
|
the RAID from a local serial terminal. The second serial port is used to upload
|
|
new programming into the 5070 (using PPP and TFTP).
|
|
<LI>Robust Unix-like command line and NVRAM based file system.
|
|
<LI>Configurable ASCII SCSI communication channel for passing commands to the 5070's
|
|
command line interpreter. Allows programming running on host OS to directly
|
|
configure/control/monitor all parameters of the 5070.
|
|
</UL>
|
|
<A NAME="toc5"></A>
|
|
<H2><A NAME="htoc7">2.2</A> Background</H2>
|
|
Much of the information/knowledge pertaining to RAID levels in this section
|
|
is adapted from the software-raid-HOWTO by Linas Vepstas . See the acknowledgements
|
|
section for the URL where the full document may be obtained. <BR>
|
|
<BR>
|
|
RAID is an acronym for "Redundant Array of Inexpensive Disks"
|
|
and is used to create large, reliable disk storage systems out of individual
|
|
hard disk drives. There are two basic ways of implementing a RAID, software
|
|
or hardware. The main advantage of a software RAID is low cost. However, since
|
|
the OS of the host system must manage the RAID directly there is a substantial
|
|
penalty in performance. Furthermore if the RAID is also the boot device, a drive
|
|
failure could prove disastrous since the operating system and utility software
|
|
needed to perform the recovery is located on the RAID. The primary advantages
|
|
of hardware RAID is performance and improved reliability. Since all RAID operations
|
|
are handled by a dedicated CPU on the controller, the host system's CPU is never
|
|
bothered with RAID related tasks. In fact the host OS is completely oblivious
|
|
to the fact that its SCSI drives are really virtual RAID drives. When a drive
|
|
fails on the 5070 it can be replaced on-the-fly with a drive from the spares
|
|
pool and its data reconstructed without the host's OS ever knowing anything
|
|
has happened.<BR>
|
|
<BR>
|
|
|
|
<H3><A NAME="htoc8">2.2.1</A> RAID levelsRaid Levels </H3>
|
|
The different RAID levels have different performance, redundancy, storage capacity,
|
|
reliability and cost characteristics. Most, but not all levels of RAID offer
|
|
redundancy against drive failure. There are many different levels of RAID which
|
|
have been defined by various vendors and researchers. The following describes
|
|
the first 7 RAID levels in the context of the Antares 5070 hardware RAID implementation.<BR>
|
|
<BR>
|
|
|
|
<H3><A NAME="htoc9">2.2.2</A> RAID linearRAID Linear</H3>
|
|
RAID-linear is a simple concatenation of drives to create a larger virtual drive.
|
|
It is handy if you have a number small drives, and wish to create a single,
|
|
large drive. This concatenation offers no redundancy, and in fact decreases
|
|
the overall reliability: if any one drive fails, the combined drive will fail.<BR>
|
|
<BR>
|
|
|
|
<H5>SUMMARY</H5>
|
|
<UL><LI>
|
|
Enables construction of a large virtual drive from a number of smaller drives
|
|
<LI>No protection, less reliable than a single drive
|
|
<LI>RAID 0 is a better choice due to better I/O performance
|
|
</UL>
|
|
|
|
<H3><A NAME="htoc10">2.2.3</A> RAID 1Level 1 </H3>
|
|
Also referred to as "mirroring". Two (or more) drives, all
|
|
of the same size, each store an exact copy of all data, disk-block by disk-block.
|
|
Mirroring gives strong protection against drive failure: if one drive fails,
|
|
there is another with the an exact copy of the same data. Mirroring can also
|
|
help improve performance in I/O-laden systems, as read requests can be divided
|
|
up between several drives. Unfortunately, mirroring is also one of the least
|
|
efficient in terms of storage: two mirrored drives can store no more data than
|
|
a single drive.<BR>
|
|
<BR>
|
|
|
|
<H5>SUMMARY</H5>
|
|
<UL><LI>
|
|
Good read/write performance
|
|
<LI>Inefficient use of storage space (half the total space available for data)
|
|
<LI>RAID 6 may be a better choice due to better I/O performance.
|
|
</UL>
|
|
|
|
<H3><A NAME="htoc11">2.2.4</A> stripingStriping</H3>
|
|
Striping is the underlying concept behind all of the other RAID levels. A stripe
|
|
is a contiguous sequence of disk blocks. A stripe may be as short as a single
|
|
disk block, or may consist of thousands. The RAID drivers split up their component
|
|
drives into stripes; the different RAID levels differ in how they organize the
|
|
stripes, and what data they put in them. The interplay between the size of the
|
|
stripes, the typical size of files in the file system, and their location on
|
|
the drive is what determines the overall performance of the RAID subsystem.<BR>
|
|
<BR>
|
|
|
|
<H3><A NAME="htoc12">2.2.5</A> RAID 0Level 0 </H3>
|
|
Similar to RAID-linear, except that the component drives are divided into stripes
|
|
and then interleaved. Like RAID-linear, the result is a single larger virtual
|
|
drive. Also like RAID-linear, it offers no redundancy, and therefore decreases
|
|
overall reliability: a single drive failure will knock out the whole thing.
|
|
However, the 5070 hardware RAID 0 is the fastest of any of the schemes listed
|
|
here.<BR>
|
|
<BR>
|
|
|
|
<H5>SUMMARY:</H5>
|
|
<UL><LI>
|
|
Use RAID 0 to combine smaller drives into one large virtual drive.
|
|
<LI>Best Read/Write performance of all the schemes listed here.
|
|
<LI>No protection from drive failure.
|
|
<LI>ADVICE: Buy very reliable hard disk drives if you plan to use this scheme.
|
|
</UL>
|
|
|
|
<H3><A NAME="htoc13">2.2.6</A> RAID 2RAID 3Level 2 and 3</H3>
|
|
RAID-2 is seldom used anymore, and to some degree has been made obsolete by
|
|
modern hard disk technology. RAID-2 is similar to RAID-4, but stores ECC information
|
|
instead of parity. Since all modern disk drives incorporate ECC under the covers,
|
|
this offers little additional protection. RAID-2 can offer greater data consistency
|
|
if power is lost during a write; however, battery backup and a clean shutdown
|
|
can offer the same benefits. RAID-3 is similar to RAID-4, except that it uses
|
|
the smallest possible stripe size.<BR>
|
|
<BR>
|
|
|
|
<H5>SUMMARY</H5>
|
|
<UL><LI>
|
|
RAID 2 is largely obsolete
|
|
<LI>Use RAID 3 to combine separate drives together into one large virtual drive.
|
|
<LI>Protection against single drive failure,
|
|
<LI>Good read/write performance.
|
|
</UL>
|
|
|
|
<H3><A NAME="htoc14">2.2.7</A> RAID 4Level 4 </H3>
|
|
RAID-4 interleaves stripes like RAID-0, but it requires an additional drive
|
|
to store parity information. The parity is used to offer redundancy: if any
|
|
one of the drives fail, the data on the remaining drives can be used to reconstruct
|
|
the data that was on the failed drive. Given N data disks, and one parity disk,
|
|
the parity stripe is computed by taking one stripe from each of the data disks,
|
|
and XOR'ing them together. Thus, the storage capacity of a an (N+1)-disk RAID-4
|
|
array is N, which is a lot better than mirroring (N+1) drives, and is almost
|
|
as good as a RAID-0 setup for large N. Note that for N=1, where there is one
|
|
data disk, and one parity disk, RAID-4 is a lot like mirroring, in that each
|
|
of the two disks is a copy of each other. However, RAID-4 does NOT offer the
|
|
read-performance of mirroring, and offers considerably degraded write performance.
|
|
In brief, this is because updating the parity requires a read of the old parity,
|
|
before the new parity can be calculated and written out. In an environment with
|
|
lots of writes, the parity disk can become a bottleneck, as each write must
|
|
access the parity disk. <BR>
|
|
<BR>
|
|
|
|
<H5>SUMMARY</H5>
|
|
<UL><LI>
|
|
Similar to RAID 0
|
|
<LI>Protection against single drive failure.
|
|
<LI>Poorer I/O performance than RAID 3
|
|
<LI>Less of the combined storage space is available for data [than RAID 3] since
|
|
an additional drive is needed for parity information.
|
|
</UL>
|
|
|
|
<H3><A NAME="htoc15">2.2.8</A> RAID 5Level 5</H3>
|
|
RAID-5 avoids the write-bottleneck of RAID-4 by alternately storing the parity
|
|
stripe on each of the drives. However, write performance is still not as good
|
|
as for mirroring, as the parity stripe must still be read and XOR'ed before
|
|
it is written. Read performance is also not as good as it is for mirroring,
|
|
as, after all, there is only one copy of the data, not two or more. RAID-5's
|
|
principle advantage over mirroring is that it offers redundancy and protection
|
|
against single-drive failure, while offering far more storage capacity when
|
|
used with three or more drives. <BR>
|
|
<BR>
|
|
|
|
<H5>SUMMARY</H5>
|
|
<UL><LI>
|
|
Use RAID 5 if you need to make the best use of your available storage space
|
|
while gaining protection against single drive failure.
|
|
<LI>Slower I/O performance than RAID 3
|
|
</UL>
|
|