<article id="ATM-Linux-HOWTO">
|
|
|
|
<articleinfo>
|
|
<title>ATM on Linux HOWTO</title>
|
|
|
|
<author>
|
|
<firstname>Paul</firstname>
|
|
<surname>Schroeder</surname>
|
|
<othername role=mi>B</othername>
|
|
<affiliation>
|
|
<orgname>IBM Corporation</orgname>
|
|
<address><email>paulsch@us.ibm.com</email></address>
|
|
</affiliation>
|
|
</author>
|
|
|
|
<abstract>
|
|
<para>
|
|
This document describes how to install, setup, and configure the necessary
|
|
drivers and tools to support ATM networking under Linux.
|
|
</para>
|
|
|
|
<para>
|
|
For the latest information, please check the
|
|
<citetitle>ATM on Linux</citetitle>
|
|
<ulink url="http://linux-atm.sourceforge.net/">home page</ulink>.
|
|
</para>
|
|
</abstract>
|
|
|
|
<releaseinfo>
|
|
ATM support for Linux is currently in pre-alpha stage. There is an experimental release, which supports raw ATM connections (PVCs and SVCs),
|
|
IP over ATM, LAN emulation, MPOA, Arequipa, and some other goodies.
|
|
</releaseinfo>
|
|
|
|
<pubdate>2001-10-18</pubdate>
|
|
<revhistory>
|
|
<revision>
|
|
<revnumber>2.4.0</revnumber>
|
|
<date>2001-10-18</date>
|
|
<authorinitials>PBS</authorinitials>
|
|
<revremark>
|
|
Converted from LaTeX to DocBook along with some
|
|
other additions and changes.
|
|
</revremark>
|
|
</revision>
|
|
</revhistory>
|
|
|
|
</articleinfo>
|
|
|
|
<sect1 id="Introduction">
|
|
<title>Introduction</title>
|
|
|
|
<sect2 id="Introduction.Acknowledgements">
|
|
<title>Acknowledgements and Thanks</title>
|
|
|
|
<para>
|
|
This document is largely derived from the
|
|
<citetitle>Usage Instructions</citetitle> document that was included with the
|
|
<emphasis>ATM on Linux</emphasis> distribution up until version 0.79. That
|
|
previous document was written by Werner Almesberger
|
|
<email>wa@almsesberger.net</email> while he was at the
|
|
<ulink url="http://icawww.epfl.ch/">Institute for computer Communications and Applications (ICA)</ulink>.
|
|
</para>
|
|
|
|
<para>
|
|
The section
|
|
<link linkend="Signaling.Running-Two-ATM-NICs-Back-to-Back" endterm="Signaling.Back-to-Back.title"></link>
|
|
was primarily written by Richard Jones <email>rjones@imcl.com</email>.
|
|
</para>
|
|
|
|
</sect2>
|
|
|
|
<sect2 id="Introduction.Copyright">
|
|
<title>Copyright</title>
|
|
|
|
<para>
|
|
Copyright 2001 IBM Corporation
|
|
</para>
|
|
|
|
<para>
|
|
Permission is granted to copy, distribute and/or modify this document under the
|
|
terms of the
|
|
<ulink url="http://www.gnu.org/copyleft/fdl.html">GNU Free Documentation License</ulink>, Version 1.1 or any later
|
|
version published by the Free Software Foundation; with no Invariant Sections, with no Front-Cover Texts, and with no Back-Cover Texts.
|
|
A copy of the license can be found at
|
|
<ulink url="http://www.gnu.org/copyleft/fdl.html">http://www.gnu.org/copyleft/fdl.html</ulink>.
|
|
</para>
|
|
|
|
<para>
|
|
A large portion of this document is derived from the
|
|
<citetitle>Usage Instructions</citetitle> included with the
|
|
<emphasis>ATM on Linux</emphasis> distribution up to version 0.79
|
|
which was released under the
|
|
BSD License, GNU General Public License (GPL), and GNU Lesser General
|
|
Public License (LGPL).
|
|
</para>
|
|
|
|
</sect2>
|
|
|
|
<sect2 id="Introduction.Mailing-List">
|
|
<title>Mailing List</title>
|
|
|
|
<para>
|
|
There is also a mailing list on which to discuss ATM on Linux. If you have any
|
|
comments, questions, suggestions, or would just like to get involved, please
|
|
join the list. You can <emphasis>subscribe</emphasis> and
|
|
<emphasis>unsubscribe</emphasis> to it at
|
|
<ulink url="http://lists.sourceforge.net/lists/listinfo/linux-atm-general">http://lists.sourceforge.net/lists/listinfo/linux-atm-general</ulink>.
|
|
</para>
|
|
|
|
<para>
|
|
The mailing list is archived at
|
|
<ulink url="http://www.geocrawler.com/lists/3/SourceForge/6487/0/">http://www.geocrawler.com/lists/3/SourceForge/6487/0/</ulink>.
|
|
</para>
|
|
</sect2>
|
|
|
|
<sect2 id="Introduction.CVS-Access">
|
|
<title>CVS Access</title>
|
|
|
|
<para>
|
|
Users are encouraged to continue to use the releases instead of automatically
|
|
assuming they should grab the latest version out of CVS. However,
|
|
if you like living on the edge, here is how to do it.
|
|
</para>
|
|
|
|
<para>
|
|
First, log in anonymously:
|
|
|
|
<informalexample><screen>
|
|
% cvs -d:pserver:anonymous@cvs.linux-atm.sourceforge.net.:/cvsroot/linux-atm login
|
|
</screen></informalexample>
|
|
|
|
Just hit return when prompted for a password. Then, checkout the repository:
|
|
|
|
<informalexample><screen>
|
|
% cvs -z6 -d:pserver:anonymous@cvs.linux-atm.sourceforge.net.:/cvsroot/linux-atm co -P linux-atm
|
|
</screen></informalexample>
|
|
|
|
You may also specify a branch to check out specifically:
|
|
<informalexample><screen>
|
|
% cvs -z6 -d:pserver:anonymous@cvs.linux-atm.sourceforge.net.:/cvsroot/linux-atm co -r V2_5_0 linux-atm
|
|
</screen></informalexample>
|
|
|
|
In either case, this will create a directory called "linux-atm" with the latest sources in it. When working inside this directory you will not need to
|
|
specify the '-d' option to CVS. For instance, you could just do
|
|
<informalexample><screen>
|
|
% cvs -z6 up -d
|
|
</screen></informalexample>
|
|
|
|
To grab any changes that have been put in the repository (the '-d' option in
|
|
the above example is to the "up" sub-command and is different than the
|
|
'-d' used to specify the CVS root directory)
|
|
</para>
|
|
|
|
<para>
|
|
After you have checked out the source tree, you will need to run the
|
|
<application>autotools</application> script in the top level directory before
|
|
you can configure, build, and install from that source tree:
|
|
|
|
<informalexample><screen>
|
|
# ./autotools
|
|
Running aclocal...
|
|
Running autoconf...
|
|
Running autoheader...
|
|
Running automake...
|
|
automake: configure.in: installing `./install-sh'
|
|
automake: configure.in: installing `./mkinstalldirs'
|
|
automake: configure.in: installing `./missing'
|
|
configure.in: 26: required file `./ltconfig' not found
|
|
automake: Makefile.am: installing `./INSTALL'
|
|
automake: configure.in: installing `src/lane/ylwrap'
|
|
Finished... Now run './configure' and 'make'...
|
|
</screen></informalexample>
|
|
|
|
</para>
|
|
|
|
<para>
|
|
|
|
If you wish to
|
|
create a tarred, gzipped distribution file or a RPM distribution file, run
|
|
<userinput>make dist</userinput> or <userinput>make rpm</userinput>
|
|
respectively. The tarred, gzipped file will be placed in the top level of
|
|
the source tree and the RPM file will be placed in the
|
|
<filename class=directory>src/extra/RPMS</filename> directory.
|
|
</para>
|
|
|
|
<para>
|
|
The CVS archive may also be browsed on the web at:
|
|
<ulink url="http://cvs.linux-atm.sourceforge.net/cgi-bin/viewcvs.cgi/linux-atm/linux-atm/">http://cvs.linux-atm.sourceforge.net/cgi-bin/viewcvs.cgi/linux-atm/linux-atm/</ulink>.
|
|
</para>
|
|
|
|
<para>
|
|
Finally, if you would like to receive email including every diff that is committed to the repository as they go in, there is a mailing list called
|
|
"linux-atm-commits":
|
|
<ulink url="http://lists.sourceforge.net/lists/listinfo/linux-atm-commits">http://lists.sourceforge.net/lists/listinfo/linux-atm-commits</ulink>.
|
|
</para>
|
|
|
|
<para>
|
|
This mailing list should be treated as receive-only. NO discussion or questions are allowed (even of patches which are sent through that list). All
|
|
discussion should be kept on the linux-atm-general mailing list.
|
|
</para>
|
|
|
|
</sect2>
|
|
|
|
|
|
</sect1>
|
|
|
|
|
|
<sect1 id="Installation">
|
|
<title>Installation</title>
|
|
|
|
<para>
|
|
In order to install this package, you'll need
|
|
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>the package itself from <ulink url="http://linux-atm.sourceforge.net/dist.php">http://linux-atm.sourceforge.net/dist.php</ulink></para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>the Linux kernel, version 2.4.x, e.g. from <ulink url="ftp://ftp.kernel.org/pub/linux/kernel/v2.4/">ftp://ftp.kernel.org/pub/linux/kernel/v2.4/</ulink></para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Perl, version 4 or 5</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>if you want memory debugging: MPR, e.g. from <ulink url="ftp://ibiblio.org/pub/Linux/devel/lang/c/">ftp://ibiblio.org/pub/Linux/devel/lang/c/</ulink></para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
|
|
</para>
|
|
|
|
<sect2 id="Installation.The-Binary-RPMs">
|
|
<title>The Binary RPMs</title>
|
|
|
|
<para>
|
|
If you do not wish to futz with extracting and building the source yourself, the
|
|
ATM tools are also distributed in RPM format. The RPM can be installed as
|
|
follows:
|
|
|
|
<informalexample><screen>
|
|
rpm -ivh <replaceable>linux-atm-x.x.x-x.rpm</replaceable>
|
|
</screen></informalexample>
|
|
</para>
|
|
|
|
</sect2>
|
|
|
|
<sect2 id="Installation.The-source-tree">
|
|
<title>The Source Tree</title>
|
|
|
|
<para>
|
|
First, extract the ATM on Linux distribution:
|
|
|
|
<informalexample><screen>
|
|
tar xzvf <replaceable>linux-atm-x.x.x.tar.gz</replaceable>
|
|
</screen></informalexample>
|
|
|
|
When extracted the distribution will create the
|
|
<filename class=directory>linux-atm-x.x.x/</filename> directory
|
|
with several sub-directories.
|
|
The following sub-directories are of note:
|
|
|
|
<variablelist>
|
|
<varlistentry><term><filename class=directory>doc/</filename></term>
|
|
<listitem>
|
|
<para>Documentation (including this HOWTO) in SGML DocBook format</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
|
|
<varlistentry><term><filename class=directory>src/sigd/</filename></term>
|
|
<listitem>
|
|
<para>UNI 3.0, UNI 3.1, and UNI 4.0 signaling demon: <application>atmsigd</application></para>
|
|
</listitem>
|
|
</varlistentry>
|
|
|
|
<varlistentry><term><filename class=directory>src/saal/</filename></term>
|
|
<listitem>
|
|
<para>Signaling AAL library (SSCOP, SSCF, and SAAL)</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
|
|
<varlistentry><term><filename class=directory>src/qgen/</filename></term>
|
|
<listitem>
|
|
<para>Q.2931-style message handling</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
|
|
<varlistentry><term><filename class=directory>src/ilmid/</filename></term>
|
|
<listitem>
|
|
<para>ILMI address registration demon: <application>ilmid</application></para>
|
|
</listitem>
|
|
</varlistentry>
|
|
|
|
<varlistentry><term><filename class=directory>src/maint/</filename></term>
|
|
<listitem>
|
|
<para>
|
|
ATM maintenance programs: <application>atmaddr</application>,
|
|
<application>atmdiag</application>, <application>atmdump</application>,
|
|
<application>atmloop</application>, <application>atmtcp</application>,
|
|
<application>enitune</application>, <application>esi</application>,
|
|
<application>sonetdiag</application>, <application>saaldump</application>, and
|
|
<application>zntune</application>
|
|
</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
|
|
<varlistentry><term><filename class=directory>src/test/</filename></term>
|
|
<listitem>
|
|
<para>
|
|
Test programs: <application>align</application>,
|
|
<application>aping</application>, <application>aread</application>,
|
|
<application>awrite</application>, <application>br</application>,
|
|
<application>bw</application>, <application>isp</application>,
|
|
<application>ttcp_atm</application>, <application>window</application>
|
|
</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
|
|
<varlistentry><term><filename class=directory>src/arpd/</filename></term>
|
|
<listitem>
|
|
<para>
|
|
ATMARP tools and demon: <application>atmarp</application>,
|
|
<application>atmarpd</application>
|
|
</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
|
|
<varlistentry><term><filename class=directory>src/led/</filename></term>
|
|
<listitem>
|
|
<para>LAN Emulation demon: <application>zeppelin</application></para>
|
|
</listitem>
|
|
</varlistentry>
|
|
|
|
<varlistentry><term><filename class=directory>src/lane/</filename></term>
|
|
<listitem>
|
|
<para>
|
|
LAN Emulation servers: <application>bus</application>,
|
|
<application>lecs</application>, <application>les</application>
|
|
</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
|
|
<varlistentry><term><filename class=directory>src/mpoad/</filename></term>
|
|
<listitem>
|
|
<para>Multi-Protocol Over ATM demon: <application>mpcd</application></para>
|
|
</listitem>
|
|
</varlistentry>
|
|
|
|
<varlistentry><term><filename class=directory>src/debug/</filename></term>
|
|
<listitem>
|
|
<para>
|
|
Debugging tools: <application>delay</application>,
|
|
<application>ed</application>, <application>encopy</application>,
|
|
<application>endump</application>,
|
|
<application>svctor</application>, <application>zndump</application>, and
|
|
<application>znth</application>
|
|
</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
|
|
<varlistentry><term><filename class=directory>src/lib/</filename></term>
|
|
<listitem>
|
|
<para>Libraries for applications and demons</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
|
|
<varlistentry><term><filename class=directory>src/man/</filename></term>
|
|
<listitem>
|
|
<para>Miscellaneous man pages</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
|
|
<varlistentry><term><filename class=directory>src/extra/</filename></term>
|
|
<listitem>
|
|
<para>
|
|
Extra packages and RPM spec files.
|
|
</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
|
|
<varlistentry><term><filename class=directory>src/config/</filename></term>
|
|
<listitem>
|
|
<para>Configuration and rc file examples</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
|
|
<varlistentry><term><filename class=directory>src/switch/</filename></term>
|
|
<listitem>
|
|
<para>Switch fabric control (under construction)</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
</variablelist>
|
|
|
|
</para>
|
|
|
|
</sect2>
|
|
|
|
<sect2 id="Installation.Kernel-Configuration">
|
|
<title>Kernel Configuration</title>
|
|
|
|
<para>
|
|
<note>
|
|
<title>NOTE</title>
|
|
<para>
|
|
If you are not familiar with building and installing a new kernel, please see
|
|
the
|
|
<ulink url="http://www.linuxdoc.org/HOWTO/Kernel-HOWTO.html"><citetitle>The Linux Kernel HOWTO</citetitle></ulink>
|
|
</para>
|
|
</note>
|
|
</para>
|
|
|
|
<para>
|
|
After unpacking the kernel distribution,
|
|
do the usual <command>make config</command>,
|
|
<command>make menuconfig</command>, or <command>make xconfig</command> in the
|
|
top-level of your Linux kernel source tree.
|
|
First, enable
|
|
<screen>
|
|
Prompt for development and/or incomplete code/drivers
|
|
(CONFIG_EXPERIMENTAL)
|
|
</screen>
|
|
|
|
You should then be able to find the following options:
|
|
|
|
<screen>
|
|
Asynchronous Transfer Mode (ATM, EXPERIMENTAL) (CONFIG_ATM)
|
|
Use "new" skb structure (CONFIG_ATM_SKB)
|
|
Classical IP over ATM (CONFIG_ATM_CLIP)
|
|
Do NOT send ICMP if no neighbour (CONFIG_ATM_CLIP_NO_ICMP)
|
|
LAN Emulation (LANE) support (CONFIG_ATM_LANE)
|
|
Multi-Protocol Over ATM (MPOA) support (CONFIG_ATM_MPOA)
|
|
ATM over TCP (CONFIG_ATM_TCP)
|
|
Efficient Networks ENI155P (CONFIG_ATM_ENI)
|
|
Enable extended debugging (CONFIG_ATM_ENI_DEBUG)
|
|
Fine-tune burst settings (CONFIG_ATM_ENI_TUNE_BURST)
|
|
Enable 16W TX bursts (discouraged) (CONFIG_ATM_ENI_BURST_TX_16W)
|
|
Enable 8W TX bursts (recommended) (CONFIG_ATM_ENI_BURST_TX_8W)
|
|
Enable 4W TX bursts (optional) (CONFIG_ATM_ENI_BURST_TX_4W)
|
|
Enable 2W TX bursts (optional) (CONFIG_ATM_ENI_BURST_TX_2W)
|
|
Enable 16W RX bursts (discouraged) (CONFIG_ATM_ENI_BURST_RX_16W)
|
|
Enable 8W RX bursts (discouraged) (CONFIG_ATM_ENI_BURST_RX_8W)
|
|
Enable 4W RX bursts (recommended) (CONFIG_ATM_ENI_BURST_RX_4W)
|
|
Enable 2W RX bursts (optional) (CONFIG_ATM_ENI_BURST_RX_2W)
|
|
ZeitNet ZN1221/ZN1225 (CONFIG_ATM_ZATM)
|
|
Enable extended debugging (CONFIG_ATM_ZATM_DEBUG)
|
|
Enable usec resolution timestamps (CONFIG_ATM_ZATM_EXACT_TS)
|
|
IDT 77201 (NICStAR) (CONFIG_ATM_NICSTAR)
|
|
Use suni PHY driver (155Mbps) (CONFIG_ATM_NICSTAR_USE_SUNI)
|
|
Use IDT77015 PHY driver (25Mbps) (CONFIG_ATM_NICSTAR_USE_IDT77105)
|
|
Madge Ambassador (Collage PCI 155 Server) (CONFIG_ATM_AMBASSADOR)
|
|
Enable debugging messages (CONFIG_ATM_AMBASSADOR_DEBUG)
|
|
Madge Horizon [Ultra] (Collage PCI 25 and Collage PCI 155 Client)
|
|
Enable debugging messages (CONFIG_ATM_HORIZON_DEBUG)
|
|
Interphase ATM PCI x575/x525/x531 (CONFIG_ATM_IA)
|
|
Enable debugging messages (CONFIG_ATM_IA_DEBUG)
|
|
</screen>
|
|
</para>
|
|
|
|
<para>
|
|
The burst settings of the ENI driver can be fine-tuned. This may be necessary
|
|
if the default settings lead to buffer overruns in the PCI chipset. See the
|
|
on-line help on "CONFIG_ATM_ENI_TUNE_BURST" for a detailed discussion
|
|
of the implications of changing the burst settings.
|
|
</para>
|
|
|
|
<para>
|
|
Note that the file <filename class=headerfile>drivers/atm/nicstar.h</filename> contains a few
|
|
configurable settings for the IDT 77201 driver.
|
|
</para>
|
|
|
|
<para>
|
|
Some drivers can also be used with certain compatible cards. The latest
|
|
information about compatible cards can be found at
|
|
<citetitle>ATM on Linux</citetitle>
|
|
<ulink url="http://linux-atm.sourceforge.net/info.php">information</ulink>
|
|
page.
|
|
</para>
|
|
|
|
<para>
|
|
Then build your kernel and reboot.
|
|
</para>
|
|
|
|
</sect2>
|
|
|
|
<sect2 id="Installation.Driver-Messages">
|
|
<title>Driver Messages</title>
|
|
|
|
<para>
|
|
If you've configured the ENI155p-MF driver, you should see two lines like
|
|
these (512kB for the -C version, 2048kB for the -S version.):
|
|
<informalexample><screen>
|
|
eni(itf 0): rev.0,base=0xff400000,irq=10,mem=512kB (00-20-EA-00-07-56)
|
|
eni(itf 0): FPGA,MMF
|
|
</screen></informalexample>
|
|
</para>
|
|
|
|
<para>
|
|
If you've configured the ZN1221/ZN1225 driver, you will get something like:
|
|
<informalexample><screen>
|
|
zatm(itf 0): rev.3,base=0xf800,irq=11,mem=128kB,MMF (00-20-D4-10-2A-80)
|
|
zatm(itf 0): uPD98401 0.5 at 30.024 MHz
|
|
zatm(itf 0): 16 shapers, 32 pools, 2048 RX, 3958 VCs
|
|
</screen></informalexample>
|
|
Note that your board needs to be at least at revision level 3 if you want
|
|
to use it in a Triton-based system.
|
|
</para>
|
|
|
|
<para>
|
|
Note that if you've configured only the ATM over TCP driver, there are no
|
|
messages at startup, because ATM over TCP devices are created later using
|
|
the <command>atmtcp</command> command.
|
|
</para>
|
|
|
|
</sect2>
|
|
|
|
<sect2 id="Installation.Memory-Debugging">
|
|
<title>Memory Debugging</title>
|
|
|
|
<para>
|
|
If you want to enable debugging for options for memory allocations, you
|
|
need to install MPR before compiling the ATM tools.
|
|
</para>
|
|
|
|
<para>
|
|
If you chose to download the binary RPM package, you can install MPR like so:
|
|
<informalexample><screen>
|
|
rpm -ivh <replaceable>mpr-x.x-x.rpm</replaceable>
|
|
</screen></informalexample>
|
|
</para>
|
|
|
|
<para>
|
|
If you chose to download the source, extract
|
|
<filename>mpr-x.x.tar.gz</filename> like so:
|
|
<informalexample><screen>
|
|
tar xzvf <replaceable>mpr-x.x.tar.gz</replaceable>
|
|
</screen></informalexample>
|
|
|
|
Then do:
|
|
<informalexample><screen>
|
|
cd <replaceable>mpr-x.x</replaceable>
|
|
./configure x86-linux
|
|
make
|
|
make install
|
|
</screen></informalexample>
|
|
</para>
|
|
|
|
<para>
|
|
Detection of some general mis-use of <function>malloc</function> and
|
|
<function>free</function> is
|
|
automatically performed if the program was compiled with MPR present.
|
|
Tracing of allocations is enabled by setting <function>MPRPC</function> and
|
|
<function>MPRFI</function>.
|
|
See <filename>doc/mpr.html</filename> or <filename>doc/mpr.ps</filename> in the
|
|
MPR distribution for details.
|
|
</para>
|
|
|
|
<para>
|
|
Only little run-time overhead is incurred if memory debugging is included,
|
|
but those environment variables are not set.
|
|
</para>
|
|
|
|
</sect2>
|
|
|
|
<sect2 id="Installation.ATM-Tools">
|
|
<title>ATM Tools</title>
|
|
|
|
<para>
|
|
Now, as the final step, configure and build the ATM tools. Configuration is
|
|
only necessary if your switch uses UNI 3.1 or 4.0, or if it has certain bugs.
|
|
The configuration options selected by passing the appropriate options to
|
|
the <command>./configure</command> script in the linux-atm distribution.
|
|
|
|
<note><title>NOTE</title>
|
|
<para>
|
|
Issue <command>./configure --help</command> from the top-level directory of the
|
|
linux-atm distribution to view all possible options.
|
|
</para>
|
|
</note>
|
|
</para>
|
|
|
|
<para>
|
|
The ATM tools are built with the following commands:
|
|
<informalexample><screen>
|
|
cd <replaceable>linux-atm-x.x.x</replaceable>
|
|
./configure
|
|
make
|
|
make install
|
|
</screen></informalexample>
|
|
|
|
Unless otherwise specified when invoking <command>./configure</command>,
|
|
<command>make install</command> will install executables in the directory
|
|
<filename class=directory>/usr/local/bin</filename> and
|
|
<filename class=directory>/usr/local/sbin</filename>,
|
|
respectively.
|
|
Configuration files (except for <filename>hosts.atm</filename> which is
|
|
installed in <filename class=directory>/etc</filename>) are installed in
|
|
<filename class=directory>/usr/local/etc</filename>.
|
|
Libraries and header files are installed in
|
|
<filename class=directory>/usr/local/lib</filename> and
|
|
<filename class=directory>/usr/local/include</filename>,
|
|
respectively. Man pages are installed in
|
|
<filename class=directory>/usr/local/man</filename>.
|
|
</para>
|
|
|
|
</sect2>
|
|
|
|
<sect2 id="Installation.Extra-Packages">
|
|
<title>Extra Packages</title>
|
|
|
|
<para>
|
|
Some programs are based on large packages that are already distributed
|
|
outside of the ATM context. For some packages, patches are contained
|
|
in the ATM on Linux distribution. They are contained in the
|
|
<filename class=directory>src/extra</filename> directory of the ATM on Linux
|
|
distribution.
|
|
</para>
|
|
|
|
<para>
|
|
Currently, the following extra packages are available:
|
|
|
|
<variablelist>
|
|
<varlistentry><term><application><ulink url="http://www.tcpdump.org/">tcpdump</ulink></application></term>
|
|
<listitem>
|
|
<para>dumps network traffic (enhanced for ATM)</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
|
|
<varlistentry><term><application>ANS</application></term>
|
|
<listitem>
|
|
<para>ATM name server (based on <application>named</application> 4.9.5)</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
</variablelist>
|
|
</para>
|
|
|
|
<para>
|
|
Note that <application>text2atm</application> automatically uses ANS if
|
|
available, so
|
|
<application>ans</application> only needs to be installed on systems providing
|
|
name server functionality or if ATM-aware maintenance tools
|
|
<application>nslookup</application>, etc.) are needed.
|
|
</para>
|
|
|
|
<para>
|
|
A script <application>hosts2ans.pl</application> to convert a
|
|
<filename>/etc/hosts.atm</filename> file to
|
|
ANS zone files are provided in the
|
|
<filename class=directory>src/extra/ANS/</filename> directory.
|
|
Its use is described at the beginning of the file.
|
|
</para>
|
|
|
|
</sect2>
|
|
|
|
</sect1>
|
|
|
|
|
|
<sect1 id="Device-Setup">
|
|
<title>Device Setup</title>
|
|
|
|
<para>
|
|
This section describes device-specific configuration operations, and general
|
|
diagnostic procedures at the ATM or SONET level. Please see the adapter
|
|
documentation for details on hardware installation and diagnosis.
|
|
</para>
|
|
|
|
<sect2 id="Device-Setup.ATM-Over-TCP-Setup">
|
|
<title>ATM Over TCP Setup</title>
|
|
|
|
<para>
|
|
If you have no real ATM hardware, you can still exercise the API by using
|
|
the ATM over TCP ``driver''. It emulates ATM devices which are directly
|
|
wired to remote devices (i.e. there is no VPI/VCI swapping).
|
|
</para>
|
|
|
|
<para>
|
|
To establish one (bidirectional) ``wire'', become root on both systems
|
|
(or run both sides on the same system to create two connected ``interfaces'')
|
|
and run the following command on one of them (let's call it ``a''):
|
|
|
|
<informalexample><screen>
|
|
# atmtcp virtual listen
|
|
</screen></informalexample>
|
|
|
|
Then, on the other system (``b''), run
|
|
|
|
<informalexample><screen>
|
|
# atmtcp virtual connect <replaceable>address_of_a</replaceable>
|
|
</screen></informalexample>
|
|
</para>
|
|
|
|
<para>
|
|
Both <command>atmtcp</command>s will report on their progress and the kernel
|
|
should display messages like:
|
|
|
|
<informalexample><screen>
|
|
Link 0: virtual interface 2
|
|
Link 1: incoming ATMTCP connection from 127.0.0.1
|
|
</screen></informalexample>
|
|
|
|
and
|
|
|
|
<informalexample><screen>
|
|
Link 0: virtual interface 3
|
|
Link 1: ATMTCP connection to localhost
|
|
</screen></informalexample>
|
|
|
|
on the two systems. Note that <command>atmtcp</command> keeps running and that interrupting
|
|
it breaks the virtual wire.
|
|
</para>
|
|
|
|
<para>
|
|
Multiple ``wires'' can be attached to the same machine by specifying a
|
|
port number (default is 2812). Note that no AAL processing is performed.
|
|
It is therefore not possible to receive data using a different AAL (e.g.
|
|
AAL0) than the one with which the data was sent.
|
|
</para>
|
|
|
|
</sect2>
|
|
|
|
<sect2 id="Device-Setup.ZN1221-ZN1225-Tuning">
|
|
<title>ZN1221/ZN1225 Tuning</title>
|
|
|
|
<para>
|
|
The ZeitNet ZN1221 and ZN1225 adapters use pre-allocated pools of free
|
|
memory buffers
|
|
for receiving. Whenever a VC with a certain maximum SDU size is opened for
|
|
receiving, the corresponding pool is filled with free buffers by the device
|
|
driver. The adapter removes buffers while it receives data. When the number
|
|
of remaining buffers falls below a certain threshold, the device driver
|
|
replenishes the pool again.
|
|
</para>
|
|
|
|
<para>
|
|
The lower and the upper limits for the number of free buffers, and the
|
|
threshold for adapting to a new data offset (see below for details), can
|
|
be set using the <application>zntune</application> program. Usage:
|
|
|
|
<cmdsynopsis>
|
|
<command>zntune</command>
|
|
<arg choice=Opt>-l <replaceable>low_water</replaceable></arg>
|
|
<arg choice=Opt>-h <replaceable>high_water</replaceable></arg>
|
|
<arg choice=Opt>-t <replaceable>threshold</replaceable></arg>
|
|
<arg choice=plain><replaceable>itf</replaceable></arg>
|
|
<arg choice=Opt><replaceable>pool</replaceable></arg>
|
|
</cmdsynopsis>
|
|
|
|
The changes are applied to all pools if no pool number is specified.
|
|
Pool 2 stores 64 bytes packets, pool 3 stores 128 bytes packets, etc.
|
|
Pools 0 and 1 are currently unused.
|
|
</para>
|
|
|
|
<para>
|
|
The current settings and some usage statistics can be obtained by invoking
|
|
<command>zntune</command> without specifying new parameters:
|
|
|
|
<cmdsynopsis>
|
|
<command>zntune</command>
|
|
<arg choice=Opt>-z</arg>
|
|
<arg choice=plain><replaceable>itf</replaceable></arg>
|
|
<arg choice=Opt><replaceable>pool</replaceable></arg>
|
|
</cmdsynopsis>
|
|
</para>
|
|
|
|
<para>
|
|
The ``Size'' column shows the buffer size in Bytes.
|
|
The ``Ref'' column shows the number of open VCs using that pool. The ``Alarm''
|
|
column shows how many times the number of free buffers has fallen below the
|
|
low-water mark since the counters were reset. Similarly, the ``Under'' column
|
|
shows how many times an incoming PDU had to be discarded because the
|
|
corresponding pool was empty.
|
|
</para>
|
|
|
|
<para>
|
|
The columns ``Offs'', ``NxOf'', ``Count'' and ``Thres'' show the alignment
|
|
adaption status. ``Offs'' is the offset of user data the driver currently
|
|
expects in incoming PDUs. For single-copy, receive buffers are aligned
|
|
accordingly so that data is received at page boundaries. ``NxOf'' is the
|
|
user data offset of the most recently received PDU, where the offset differs
|
|
from the currently assumed offset. ``Count'' is the number of PDUs that have
|
|
been received in sequence with an offset of ``NxOf''. Finally, ``Thres'' is
|
|
the threshold value ``Count'' has to reach for ``NxOf'' to become the new
|
|
current offset.
|
|
</para>
|
|
|
|
<para>
|
|
Use the <parameter class=command>-z</parameter> option to reset the ``Alarm''
|
|
and ``Under'' counters.
|
|
</para>
|
|
|
|
</sect2>
|
|
|
|
<sect2 id="Device-Setup.Files-in-proc-net-atm">
|
|
<title>Files in <filename class=directory>/proc/net/atm/</filename></title>
|
|
|
|
<para>
|
|
Some status information about the ATM subsystem can be obtained through files
|
|
in <filename class=directory>/proc/net/atm/</filename>.
|
|
The file <filename>/proc/net/atm/arp</filename> contains information
|
|
specific to Classical IP over ATM, see section
|
|
<link linkend="IP-Over-ATM.CLIP" endterm="IP-Over-ATM.CLIP.title"></link>.
|
|
</para>
|
|
|
|
<para>
|
|
All active ATM devices are listed in <filename>/proc/net/atm/devices</filename>.
|
|
For each device,
|
|
the interface number, the type label, the end system identifier (ESI), and
|
|
statistics are shown. The statistics correspond to the ones available via
|
|
<application>atmdiag</application>.
|
|
</para>
|
|
|
|
<para>
|
|
Individual ATM devices may register entries of the form
|
|
<literal><replaceable>type:number</replaceable></literal>
|
|
(e.g. <literal>eni:0</literal>) which contain
|
|
device-specific information.
|
|
</para>
|
|
|
|
<para>
|
|
The files <filename>/proc/net/atm/pvc</filename> and
|
|
<filename>/proc/net/atm/svc</filename> list all PVC and SVC
|
|
sockets.
|
|
For both types of sockets, the interface, VPI and VCI numbers are shown. For
|
|
PVCs, this is followed by the AAL and the traffic class and the selected
|
|
PCR for the receive and the transmit direction. For SVCs, the SVC state
|
|
and the address of the remote party are shown. SVCs with the interface
|
|
number 999 are used for special control purposes as indicated in the ``State''
|
|
column.
|
|
</para>
|
|
|
|
<para>
|
|
Furthermore, <filename>/proc/net/atm/vc</filename> shows buffer sizes and
|
|
additional internal information for all ATM sockets.
|
|
</para>
|
|
|
|
</sect2>
|
|
|
|
<sect2 id="Device-Setup.ATM-Diagnostics">
|
|
<title>ATM Diagnostics</title>
|
|
|
|
<para>
|
|
Various counters of the ATM device drivers can be queried with the
|
|
<application>atmdiag</application> program. See the corresponding man page
|
|
for details.
|
|
</para>
|
|
|
|
</sect2>
|
|
|
|
<sect2 id="Device-Setup.SONET-Diagnostics">
|
|
<title>SONET Diagnostics</title>
|
|
|
|
<para>
|
|
The SONET diagnostics tool can be used to monitor link performance
|
|
and to simulate errors. In order to get current SONET statistics,
|
|
run it with the ATM interface number as the argument, e.g.
|
|
|
|
<informalexample><screen>
|
|
% sonetdiag 0
|
|
</screen></informalexample>
|
|
</para>
|
|
|
|
<para>
|
|
The counters can be reset with the <parameter class=command>-z</parameter>
|
|
option:
|
|
|
|
<informalexample><screen>
|
|
# sonetdiag -z 0
|
|
</screen></informalexample>
|
|
</para>
|
|
|
|
<para>
|
|
The following network failures can be simulated:<footnote>
|
|
<para>
|
|
Some adapters may only support a subset of this.
|
|
</para>
|
|
</footnote>
|
|
|
|
<variablelist>
|
|
<varlistentry><term><errorcode>sbip</errorcode></term>
|
|
<listitem>
|
|
<para>insert section errors (B1)</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
<varlistentry><term><errorcode>lbip</errorcode></term>
|
|
<listitem>
|
|
<para>insert line errors (B2)</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
<varlistentry><term><errorcode>pbip</errorcode></term>
|
|
<listitem>
|
|
<para>insert path errors (B3)</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
<varlistentry><term><errorcode>frame</errorcode></term>
|
|
<listitem>
|
|
<para>force (RX) frame loss</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
<varlistentry><term><errorcode>los</errorcode></term>
|
|
<listitem>
|
|
<para>insert loss of signal</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
<varlistentry><term><errorcode>lais</errorcode></term>
|
|
<listitem>
|
|
<para>insert line alarm indication signal</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
<varlistentry><term><errorcode>pais</errorcode></term>
|
|
<listitem>
|
|
<para>insert path alarm indication signal</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
<varlistentry><term><errorcode>hcs</errorcode></term>
|
|
<listitem>
|
|
<para>insert header checksum errors</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
</variablelist>
|
|
</para>
|
|
|
|
<para>
|
|
A failure is enabled by adding the corresponding keyword on the
|
|
command line. The failure is cleared by prefixing the keyword with
|
|
a minus sign, e.g.
|
|
|
|
<informalexample><screen>
|
|
a# sonetdiag -z 0 >/dev/null
|
|
b# sonetdiag -z 0 >/dev/null
|
|
a# sonetdiag 0 los
|
|
a# sonetdiag 0 -los
|
|
b# sonetdiag 0 | grep BIP
|
|
Section BIP errors: 56200
|
|
Line BIP errors: 342
|
|
Path BIP errors: 152
|
|
a# sonetdiag 0 | grep FEBE
|
|
Line FEBE: 342
|
|
Path FEBE: 152
|
|
</screen></informalexample>
|
|
</para>
|
|
|
|
<para>
|
|
If any diagnostic error insertions are active, their keywords are
|
|
shown when <application>sonetdiag</application> is used to obtain statistics.
|
|
Note that some error insertions may be automatically switched off by the
|
|
hardware.
|
|
</para>
|
|
|
|
</sect2>
|
|
|
|
</sect1>
|
|
|
|
<sect1 id="Native-ATM-PVCs">
|
|
<title>Native ATM PVCs</title>
|
|
|
|
<para>
|
|
PVCs can be used for machines that are either connected back to back or
|
|
via a switch. In the latter case, the cell forwarding has to be manually
|
|
set up at the switch.
|
|
</para>
|
|
|
|
<sect2 id="Native-ATM-PVCs.Traffic-Tools">
|
|
<title>Traffic Tools</title>
|
|
|
|
<para>
|
|
<application>aread</application>/<application>awrite</application> and
|
|
<application>br</application>/<application>bw</application> are simple programs
|
|
to access the ATM API. <application>awrite</application> sends the text string
|
|
passed as its second argument in an AAL5 PDU. <application>aread</application>
|
|
receives one AAL5 PDU and
|
|
displays it in hex. Both programs also display the return values of the
|
|
corresponding system calls and the current values of
|
|
<errorcode>errno</errorcode>.
|
|
</para>
|
|
|
|
<para>
|
|
<application>bw</application> either sends its standard input or a stream of
|
|
blocks containing
|
|
arbitrary data (if a number is passed as its fourth argument) in 8 kB
|
|
AAL5 PDUs. <application>br</application> receives AAL5 PDUs and writes them
|
|
to standard output.
|
|
</para>
|
|
|
|
<para>
|
|
The first argument of <application>aread</application>,
|
|
<application>awrite</application>, <application>br</application> and
|
|
<application>bw</application> is always the PVC address,
|
|
i.e. the ATM interface number, the VPI and the VCI number, with a dot
|
|
between elements. The interface number can be omitted if it is zero.
|
|
Example:
|
|
|
|
<informalexample><screen>
|
|
% awrite 1.0.42 hi
|
|
</screen></informalexample>
|
|
</para>
|
|
|
|
<para>
|
|
Note that some adapters only support VPI == 0. Also, the VCI range may be
|
|
limited, e.g 0 to 1023.
|
|
The interface number can be obtained from the initialization
|
|
message the driver printed during startup. <interfacename>atm0</interfacename>
|
|
is interface 0, <interfacename>atm1</interfacename> is interface 1, etc. If the
|
|
system is equipped with a real
|
|
ATM adapter (e.g. not only <application>atmtcp</application>),
|
|
that adapter is normally at <interfacename>atm0</interfacename>.
|
|
</para>
|
|
|
|
<para>
|
|
<application>aping</application> receives and sends small AAL5 PDUs on a PVC.
|
|
It expects that
|
|
messages it sends are either echoed back or that a similar program on the
|
|
other side generates a stream of messages. <application>aping</application>
|
|
reports an error if no messages are received for too long.
|
|
<application>aping</application> is invoked by
|
|
specifying the PVC, like <application>aread</application>.
|
|
</para>
|
|
|
|
<para>
|
|
For "real" tests, you should use the modified version of
|
|
<application>ttcp</application> that
|
|
comes with this package. The original is available at
|
|
<ulink url="ftp://ftp.sgi.com/sgi/src/ttcp/">ftp://ftp.sgi.com/sgi/src/ttcp/</ulink>.
|
|
The following options have been added:
|
|
|
|
|
|
<variablelist>
|
|
<varlistentry><term><parameter class=command>-a</parameter></term>
|
|
<listitem>
|
|
<para>
|
|
use native ATM instead of UDP/TCP. The address must be in
|
|
the format
|
|
<parameter class=command>[<replaceable class=option>itf.</replaceable>]vpi.vci</parameter>
|
|
for PVCs, or a
|
|
valid ATM end system address for SVCs.
|
|
</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
<varlistentry><term><parameter class=command>-P</parameter> <replaceable>num</replaceable></term>
|
|
<listitem>
|
|
<para>use a CBR connection with a peak cell rate of
|
|
<replaceable>num</replaceable> cells per second. Default is to use UBR.
|
|
</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
<varlistentry><term><parameter class=command>-C</parameter></term>
|
|
<listitem>
|
|
<para>disable (UDP) checksums</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
</variablelist>
|
|
|
|
Example:
|
|
<informalexample><screen>
|
|
%a ttcp_atm -r -a -s 0.90
|
|
%b ttcp_atm -t -a -s 0.90
|
|
</screen></informalexample>
|
|
</para>
|
|
|
|
</sect2>
|
|
|
|
<sect2 id="Native-ATM-PVCs.Direct-Cell-Access">
|
|
<title>Direct Cell Access</title>
|
|
|
|
<para>
|
|
On adapters where the device driver supports access to raw cells (``AAL0''),
|
|
individual cells can be composed and received with the
|
|
<application>atmdump</application> program.
|
|
|
|
Here is an example:
|
|
<informalexample><screen>
|
|
a% sleep 10; date | ./atmdump -t 1 -c 0.51
|
|
b% ./atmdump 0.51
|
|
825079645.192480: VPI=0 VCI=51, GFC=0x0, CLP=1, Data SDU 1 (PTI 1)
|
|
46 72 69 20 46 65 62 20 32 33 20 31 32 3a 34 37
|
|
3a 32 35 20 47 4d 54 20 31 39 39 36 0a 00 00 00
|
|
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
|
</screen></informalexample>
|
|
</para>
|
|
|
|
</sect2>
|
|
|
|
</sect1>
|
|
|
|
|
|
<sect1 id="Signaling">
|
|
<title>Signaling</title>
|
|
|
|
<sect2 id="Signaling.ATM-Hosts-File">
|
|
<title>ATM Hosts File</title>
|
|
|
|
<para>
|
|
Because ATM addresses are inconvenient to use, most ATM tools also
|
|
accept names instead of numeric addresses. The mapping between names and
|
|
numbers is defined in the file <filename>/etc/hosts.atm</filename>.
|
|
The structure of
|
|
this file is similar to the <filename>/etc/hosts</filename> file:
|
|
|
|
<informalexample><screen>
|
|
<replaceable>numeric_address</replaceable> <replaceable>name(s)</replaceable>
|
|
</screen></informalexample>
|
|
|
|
e.g.
|
|
|
|
<informalexample><screen>
|
|
47.0005.80FFE1000000F21A26D8.0020EA000EE0.00 pc2-a.fqdn pc2-a
|
|
47.0005.80FFE1000000F21A26D8.0020D4102A80.00 pc3-a.fqdn pc3-a
|
|
</screen></informalexample>
|
|
</para>
|
|
|
|
<para>
|
|
The numeric address can be specified in any of the formats described
|
|
in [<xref linkend="api">].
|
|
The numeric address(es) of a Linux system can be
|
|
determined with the command <command>atmaddr <option>-n</option></command>
|
|
(see also section
|
|
<link linkend="Signaling.Manual-Address-Configuration" endterm="Signaling.Manual-Address-Configuration.title"></link>).
|
|
</para>
|
|
|
|
<para>
|
|
Many ATM tools also attempt to find the corresponding name when displaying
|
|
an address. When translating from the numeric form to a name, the first
|
|
applicable name in the file is used.
|
|
</para>
|
|
|
|
<para>
|
|
In addition to ATM addresses for SVCs, also PVC addresses can be stored in
|
|
<filename>/etc/hosts.atm</filename>.
|
|
If different address types are stored under the
|
|
same name, the first suitable one will be chosen, i.e. if an application
|
|
explicitly requests only SVC addresses, any PVC addresses will be ignored.
|
|
</para>
|
|
|
|
</sect2>
|
|
|
|
<sect2 id="Signaling.ANS">
|
|
<title>ANS</title>
|
|
|
|
<para>
|
|
If you have access to the ATM Name Service (ANS, e.g because you've installed
|
|
the ANS extension), you can use it instead of or in addition to the hosts
|
|
file by specifying the host that runs ANS in the
|
|
<filename>/etc/resolv.conf</filename> file.
|
|
</para>
|
|
|
|
<para>
|
|
For performing reverse lookups of E.164 addresses, the list of telephony
|
|
country codes needs to be known. That list can be obtained from the
|
|
<ulink url="http://www.itu.org/">International Telecommunications Union</ulink>.
|
|
The
|
|
<ulink url="http://www.itu.int/itudoc/itu-t/ob-lists/icc/e164_717.html"><citetitle>List of ITU-T Recommendation E.164 Assigned Country Codes</citetitle></ulink>
|
|
is currently available in PDF and Word document formats.
|
|
<note>
|
|
<title>NOTE</title>
|
|
<para>
|
|
Should the URL become out of date, the document should easily be found by
|
|
searching for the document's title at the ITU web site.
|
|
</para>
|
|
</note>
|
|
</para>
|
|
|
|
<para>
|
|
The script
|
|
<command>src/lib/pdf2e164_cc.pl</command> in the atm-linux distribution can
|
|
be used to create the E.164 county codes table with the PDF version
|
|
of the country code list, e.g.
|
|
|
|
<informalexample><screen>
|
|
perl pdf2e164_cc.pl <replaceable>e164_xxx.pdf</replaceable> >/etc/e164_cc
|
|
</screen></informalexample>
|
|
|
|
It should be noted that <application>pdftotext</application> needs to be
|
|
available in order to run the script above. It can be obtained with
|
|
<ulink url="http://www.foolabs.com/xpdf/"><application>xpdf</application></ulink>.
|
|
</para>
|
|
|
|
</sect2>
|
|
|
|
<sect2 id="Signaling.Signaling-Demon">
|
|
<title>Signaling Demon</title>
|
|
|
|
<para>
|
|
Man pages:
|
|
<citerefentry><refentrytitle>atmsigd</refentrytitle><manvolnum>8</manvolnum></citerefentry>
|
|
<citerefentry><refentrytitle>atmsigd.conf</refentrytitle><manvolnum>4</manvolnum></citerefentry>
|
|
</para>
|
|
|
|
<para>
|
|
Note that <application>atmsigd</application>'s support for point-to-multipoint
|
|
is very limited:
|
|
only operation as a single leaf of a point-to-multipoint tree works.
|
|
</para>
|
|
|
|
<para>
|
|
By default, <application>atmsigd</application> is configured to conform to
|
|
dynamically configure the UNI version. It can be
|
|
compiled for UNI 3.0, 3.1, or 4.0 specifically by passing the
|
|
<parameter class=command>--with-uni=VERSION</parameter> to the
|
|
<command>./configure</command> script in the top-level directory of the
|
|
linux-atm source distribution.
|
|
</para>
|
|
|
|
<para>
|
|
Note that <application>atmsigd</application> is configured to be paranoid.
|
|
If it detects unusual
|
|
problems, it frequently terminates. This will (obviously) change in the
|
|
future.
|
|
</para>
|
|
|
|
<para>
|
|
<application>atmsigd</application> also looks for a configuration file at the
|
|
location specified
|
|
with the <parameter class=command>-c</parameter> option.
|
|
The default location is <filename>/usr/local/etc/atmsigd.conf</filename>.
|
|
</para>
|
|
</sect2>
|
|
|
|
<sect2 id="Signaling.ILMI-Demon">
|
|
<title>ILMI Demon</title>
|
|
|
|
<para>
|
|
ILMI provides a mechanism for automatic address configuration. If there is
|
|
no switch or if the switch doesn't support ILMI, the ATM addresses must
|
|
be configured manually (see section
|
|
<link linkend="Signaling.Manual-Address-Configuration" endterm="Signaling.Manual-Address-Configuration.title"></link>).
|
|
Note that the ILMI
|
|
demon should not be used on interfaces where addresses are manually
|
|
configured.
|
|
</para>
|
|
|
|
<para>
|
|
The ILMI demon is started as follows:
|
|
|
|
<cmdsynopsis>
|
|
<command>ilmid</command>
|
|
<arg choice=Opt>-b</arg>
|
|
<arg choice=Opt>-d</arg>
|
|
<arg choice=Opt>-i <replaceable>local_ip</replaceable></arg>
|
|
<arg choice=Opt>-l <replaceable>log_file</replaceable></arg>
|
|
<arg choice=Opt>-q <replaceable>qos</replaceable></arg>
|
|
<arg choice=Opt>-u <replaceable>uni_version</replaceable></arg>
|
|
<arg choice=Opt>-v</arg>
|
|
<arg choice=Opt>-x</arg>
|
|
<arg choice=Opt><replaceable>itf</replaceable></arg>
|
|
</cmdsynopsis>
|
|
|
|
<variablelist>
|
|
<varlistentry><term><parameter class=command>-b</parameter></term>
|
|
<listitem>
|
|
<para>background. Run in a forked child process after initializing.</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
<varlistentry><term><parameter class=command>-d</parameter></term>
|
|
<listitem>
|
|
<para>enables debugging output. By default, <application>ilmid</application> is very quiet.</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
<varlistentry><term><parameter class=command>-i</parameter> <replaceable>local_ip</replaceable></term>
|
|
<listitem>
|
|
<para>
|
|
IP address to tell switch when asked for one.
|
|
Can be in either dotted decimal or textual format.
|
|
By default, <application>ilmid</application>
|
|
uses some heuristics to select a local IP address.
|
|
</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
<varlistentry><term><parameter class=command>-l</parameter> <replaceable>logfile</replaceable></term>
|
|
<listitem>
|
|
<para>
|
|
write diagnostic messages to the specified
|
|
file instead of to standard error.
|
|
The special name <parameter class=command>syslog</parameter> is
|
|
used to send diagnostics to the system logger.
|
|
</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
<varlistentry><term><parameter class=command>-q</parameter> <replaceable>qos</replaceable></term>
|
|
<listitem>
|
|
<para>
|
|
configures the ILMI VC to use the specified
|
|
quality of service. By default, UBR at link speed is used on the ILMI VC.
|
|
</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
<varlistentry><term><parameter class=command>-u</parameter> <replaceable>uni_version</replaceable></term>
|
|
<listitem>
|
|
<para>
|
|
set UNI version. Possible values are
|
|
<parameter class=command>3.0</parameter>,
|
|
<parameter class=command>3.1</parameter>, and
|
|
<parameter class=command>4.0</parameter>. The dot can be omitted. The default
|
|
value depends on how <application>ilmid</application> was compiled.
|
|
Typically, it is <parameter class=command>3.0</parameter>.
|
|
</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
<varlistentry><term><parameter class=command>-v</parameter></term>
|
|
<listitem>
|
|
<para>enables extensive debugging output.</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
<varlistentry><term><parameter class=command>-x</parameter></term>
|
|
<listitem>
|
|
<para>
|
|
disable inclusion of variable bindings in the
|
|
ColdstartTrap. Some switches (e.g. the LS100) only work if this option is set.
|
|
</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
</variablelist>
|
|
|
|
</para>
|
|
|
|
<para>
|
|
If no interface number is specified, <application>ilmid</application>
|
|
serves interface 0.
|
|
You can check whether address registration was successful with the
|
|
<command>atmaddr</command> command (see below).
|
|
</para>
|
|
|
|
<para>
|
|
The agent supports only the address registration procedures specified
|
|
in section 5.8 of the ATM Forum's UNI 3.1 specification. These
|
|
procedures involve the switch registering the network prefix on the
|
|
host and the host registering the final ATM address back on the
|
|
switch. The host accomplishes this by appending an ESI (End System
|
|
Identifier) and a null selector byte to the network prefix registered
|
|
by the switch. The ESI is the physical or MAC address of the ATM
|
|
interface.
|
|
</para>
|
|
</sect2>
|
|
|
|
<sect2 id="Signaling.Manual-Address-Configuration">
|
|
<title id="Signaling.Manual-Address-Configuration.title">Manual Address Configuration</title>
|
|
|
|
<para>
|
|
If your switch doesn't support ILMI, you have to set the ATM address
|
|
manually on the switch and on the PC(s). On the Linux side, make sure that
|
|
<application>ilmid</application> doesn't interfere, then use the
|
|
<command>atmaddr</command> command to set
|
|
the address(es).
|
|
</para>
|
|
|
|
<para>
|
|
Man pages:
|
|
<citerefentry><refentrytitle>atmaddr</refentrytitle><manvolnum>8</manvolnum></citerefentry>
|
|
</para>
|
|
|
|
<para>
|
|
Manual configuration of ATM addresses on the switch depends on the brand.
|
|
On a Fore ASX-200, it can be done with the following command:
|
|
|
|
<informalexample><screen>
|
|
conf nsap route new <replaceable>nsap_addr</replaceable> 152 <replaceable>port</replaceable> <replaceable>vpi</replaceable>
|
|
</screen></informalexample>
|
|
|
|
e.g.
|
|
|
|
<informalexample><screen>
|
|
conf nsap route new 47000580ffe1000000f21510650020ea000ee000 152 1a2 0
|
|
|<---- NSAP prefix ----->||<--ESI--->|^^
|
|
SEL
|
|
</screen></informalexample>
|
|
</para>
|
|
|
|
<para>
|
|
The entire NSAP address always has to have a length of 40 digits.
|
|
Note that you can also use addresses with a different prefix and an ESI
|
|
that doesn't correspond to any ESI your adapters have. The value of the
|
|
selector byte (SEL) is ignored.
|
|
</para>
|
|
|
|
</sect2>
|
|
|
|
<sect2 id="Signaling.Running-Two-ATM-NICs-Back-to-Back">
|
|
<title id="Signaling.Back-to-Back.title">Running Two ATM NICs Back-to-Back</title>
|
|
|
|
<para>
|
|
It is also possible to run with two ATM NICs connected back-to-back,
|
|
and no switch in between.
|
|
This is great for simple test environments.
|
|
</para>
|
|
|
|
<para>
|
|
First, if you're using UTP or STP-5, you need a suitable cable. Our
|
|
experience with standard 100Base-T back-to-back cables was not
|
|
good. It appears that the pin-out they use is different. After some
|
|
false starts, we found that the following cable works:
|
|
|
|
<informalexample><screen>
|
|
RJ45 RJ45
|
|
1 ------------ 7
|
|
2 ------------ 8
|
|
|
|
7 ------------ 1
|
|
8 ------------ 2
|
|
|
|
Pins 3, 4, 5, 6 unconnected.
|
|
</screen></informalexample>
|
|
|
|
A better way to illustrate this may be to show the proper color
|
|
schemes for the RJ45 connectors at each end of the back-to-back cable.
|
|
The first connector should use the following scheme:
|
|
|
|
<informalexample><screen>
|
|
RJ45-1
|
|
1 - Brown
|
|
2 - White/Brown
|
|
3 - Unconnected
|
|
4 - Unconnected
|
|
5 - Unconnected
|
|
6 - Unconnected
|
|
7 - Orange
|
|
8 - White/Orange
|
|
</screen></informalexample>
|
|
|
|
And the second connector should use this scheme:
|
|
|
|
<informalexample><screen>
|
|
RJ45-2
|
|
1 - Orange
|
|
2 - White/Orange
|
|
3 - Unconnected
|
|
4 - Unconnected
|
|
5 - Unconnected
|
|
6 - Unconnected
|
|
7 - Brown
|
|
8 - White/Brown
|
|
</screen></informalexample>
|
|
|
|
</para>
|
|
|
|
<para>
|
|
You can also make up a loopback cable with 1 -- 7 and 2 -- 8 connected for
|
|
ultra-cheap setups.
|
|
</para>
|
|
|
|
<para>
|
|
Here we have two machines called ``virgil'' and ``nestor''.
|
|
Substitute your own names as necessary.
|
|
</para>
|
|
|
|
<para>
|
|
One side of the ATM connection needs to use the network version of
|
|
<application>atmsigd</application> and the other side should use the
|
|
normal user version.
|
|
So here on nestor we start <application>atmsigd</application> with:
|
|
|
|
<informalexample><screen>
|
|
atmsigd -b -m network
|
|
</screen></informalexample>
|
|
|
|
and on virgil with:
|
|
|
|
<informalexample><screen>
|
|
atmsigd -b
|
|
</screen></informalexample>
|
|
</para>
|
|
|
|
<para>
|
|
Without a switch, you won't be able to use ILMI. Instead, create a
|
|
<filename>/etc/hosts.atm</filename> file containing two dummy addresses.
|
|
Our ATM hosts file contains:
|
|
|
|
<informalexample><screen>
|
|
47.0005.80FFE1000000F21A26D8.0020EA000EE0.00 nestor-atm
|
|
47.0005.80FFE1000000F21A26D8.0020D4102A80.00 virgil-atm
|
|
</screen></informalexample>
|
|
</para>
|
|
|
|
<para>
|
|
These are completely spurious addresses, of course, but as long as you're
|
|
not connected to a public or private ATM network, I don't think it matters.
|
|
To set the address correctly in the driver, we use:
|
|
|
|
<informalexample><screen>
|
|
atmaddr -a virgil-atm
|
|
</screen></informalexample>
|
|
|
|
on virgil, and:
|
|
|
|
<informalexample><screen>
|
|
atmaddr -a nestor-atm
|
|
</screen></informalexample>
|
|
|
|
on nestor. Now start <application>atmarpd</application> on both machines
|
|
in the normal way. Now you (should) have a working ATM set-up. To get
|
|
IP over ATM working, just follow the instructions in
|
|
section <link linkend="IP-Over-ATM" endterm="IP-Over-ATM.title"></link>.
|
|
</para>
|
|
|
|
</sect2>
|
|
|
|
<sect2 id="Signaling.Q-2931-Message-Dumper">
|
|
<title>Q.2931 Message Dumper</title>
|
|
|
|
<para>
|
|
The Q.2931 message compiler also generates a pretty-printer for Q.2931
|
|
messages. The executable is called <application>q.dump</application>
|
|
is stored in the
|
|
<filename>src/qgen</filename> directory. Note that it is not copied elsewhere
|
|
by <command>make install</command>.
|
|
</para>
|
|
|
|
<para>
|
|
<application>q.dump</application> expects a sequence of whitespace-separated
|
|
hex bytes at standard
|
|
input and outputs the message structure if the message can be parsed.
|
|
|
|
Example:
|
|
|
|
<informalexample><screen>
|
|
% echo 09 03 80 00 05 5A 80 00 06 08 80 00 02 81 83 00 48 \
|
|
00 00 08 | ./q.dump
|
|
_pdsc = 9 "Q.2931 user-network call/connection control message"
|
|
_cr_len = 3
|
|
call_ref = 8388613 (0x800005)
|
|
msg_type = 0x5a "RELEASE COMPLETE"
|
|
_ext = 1
|
|
_flag = 0 "instruction field not significant"
|
|
_action_ind = 0 "clear call"
|
|
msg_len = 6 (0x6)
|
|
_ie_id = 0x08 "Cause"
|
|
_ext = 1
|
|
cause_cs = 0 "ITU-T standardized"
|
|
_flag = 0 "instruction field not significant"
|
|
_action_ind = 0 "clear call"
|
|
_ie_len = 2 (0x2)
|
|
_ext = 1
|
|
location = 1 "private network serving the local user"
|
|
_ext = 1
|
|
cause = 3 "no route to destination"
|
|
</screen></informalexample>
|
|
|
|
</para>
|
|
|
|
</sect2>
|
|
|
|
</sect1>
|
|
|
|
|
|
<sect1 id="IP-Over-ATM">
|
|
<title id="IP-Over-ATM.title">IP Over ATM</title>
|
|
|
|
<para>
|
|
IP over ATM is supported with Classical IP over ATM (CLIP, defined in
|
|
RFC1577 [<xref linkend="RFC1577">], LAN Emulation (LANE, defined in
|
|
[<xref linkend="lanev1">] and [<xref linkend="lanev2">])
|
|
and Multi-Protocol Over ATM (MPOA, client only, defined in
|
|
[<xref linkend="mpoav1">]).
|
|
</para>
|
|
|
|
<sect2 id="IP-Over-ATM.CLIP">
|
|
<title id="IP-Over-ATM.CLIP.title">CLIP</title>
|
|
|
|
<para>
|
|
A demon process is used to generate and answer ARP queries.
|
|
The actual kernel part maintains a small lookup table only containing partial
|
|
information.
|
|
</para>
|
|
|
|
<para>
|
|
Man pages:
|
|
<citerefentry><refentrytitle>atmarpd</refentrytitle><manvolnum>8</manvolnum></citerefentry>,
|
|
<citerefentry><refentrytitle>atmarp</refentrytitle><manvolnum>8</manvolnum></citerefentry>
|
|
</para>
|
|
|
|
<para>
|
|
<application>atmsigd</application> and <application>ilmid</application>
|
|
must already be running when <application>atmarpd</application> is
|
|
started. Use the <parameter class=command>-b</parameter>
|
|
option to make sure they're properly synchronized,
|
|
e.g.
|
|
|
|
<informalexample><screen>
|
|
#!/bin/sh
|
|
atmsigd -b
|
|
ilmid -b
|
|
atmarpd -b
|
|
...
|
|
</screen></informalexample>
|
|
|
|
works, but
|
|
|
|
<informalexample><screen>
|
|
#!/bin/sh
|
|
atmsigd &
|
|
ilmid &
|
|
atmarpd &
|
|
...
|
|
</screen></informalexample>
|
|
|
|
frequently doesn't (yet).
|
|
</para>
|
|
|
|
<para>
|
|
The <application>atmarp</application> program is used to configure ATMARP.
|
|
First, you have to
|
|
start <application>atmsigd</application>, <application>ilmid</application>, and
|
|
<application>atmarpd</application>, then create an IP
|
|
interface and configure it:
|
|
|
|
<informalexample><screen>
|
|
# atmarp -c <replaceable>interface_name</replaceable>
|
|
# ifconfig atm0 <replaceable>local_address</replaceable> <replaceable>possibly_more_options</replaceable> up
|
|
</screen></informalexample>
|
|
|
|
e.g.
|
|
|
|
<informalexample><screen>
|
|
# atmarp -c atm0
|
|
# ifconfig atm0 10.0.0.3 up
|
|
</screen></informalexample>
|
|
</para>
|
|
|
|
<para>
|
|
If only PVCs will be used, they can now be created with a command like
|
|
|
|
<informalexample><screen>
|
|
# atmarp -s 10.0.0.4 0.0.70
|
|
</screen></informalexample>
|
|
</para>
|
|
|
|
<para>
|
|
NULL encapsulation is used if the <parameter class=command>null</parameter>
|
|
keyword is specified.
|
|
Note that ARP requires LLC/SNAP encapsulation. NULL encapsulation can
|
|
therefore only be used for PVCs.
|
|
</para>
|
|
|
|
<para>
|
|
When using SVCs, some additional configuration work may be necessary. If the
|
|
machine is acting as the ATMARP server on that LIS, no additional
|
|
configuration is required. Otherwise, the ATM address of the ATMARP
|
|
server has to be configured. This is done by creating an entry for the
|
|
network address with the option <parameter class=command>arpsrv</parameter>
|
|
set, e.g.
|
|
|
|
<informalexample><screen>
|
|
# atmarp -s \
|
|
10.0.0.0 47.0005.80.ffe100.0000.f215.1065.0020EA000756.00 \
|
|
arpsrv
|
|
</screen></informalexample>
|
|
</para>
|
|
|
|
<para>
|
|
Note that the ATMARP server currently has to be started and configured
|
|
before any clients are configured.
|
|
</para>
|
|
|
|
<para>
|
|
The kernel ATMARP table can be read via \path{/proc/net/atm/arp}. The table
|
|
used by <application>atmarpd</application>
|
|
is regularly printed on standard error if <application>atmarpd</application>
|
|
is started with the <parameter class=command>-d</parameter> option.
|
|
If <application>atmarpd</application> is invoked without
|
|
<parameter class=command>-d</parameter>, the table is written to the file
|
|
<filename>atmarpd.table</filename> in the dump
|
|
directory (by default <filename class=directory>/var/run</filename>; can be
|
|
changed with <parameter class=command>-D</parameter>), and
|
|
it can be read with <command>atmarp -a</command>.
|
|
</para>
|
|
|
|
</sect2>
|
|
|
|
<sect2 id="IP-Over-ATM.LAN-Emulation">
|
|
<title id="IP-Over-ATM.LAN-Emulation.title">LAN Emulation</title>
|
|
|
|
<para>
|
|
Besides Classical IP over ATM, LAN Emulation (LANE) can be used to
|
|
carry IP over ATM. LANE emulates the characteristics of legacy LAN
|
|
technology, such as support for broadcasts. LANE server support is
|
|
described in the <filename>src/lane/USAGE</filename> file in the linux-atm
|
|
distribution.
|
|
</para>
|
|
|
|
<para>
|
|
Man pages:
|
|
<citerefentry><refentrytitle>bus</refentrytitle><manvolnum>8</manvolnum></citerefentry>,
|
|
<citerefentry><refentrytitle>lecs</refentrytitle><manvolnum>8</manvolnum></citerefentry>,
|
|
<citerefentry><refentrytitle>les</refentrytitle><manvolnum>8</manvolnum></citerefentry>, and
|
|
<citerefentry><refentrytitle>zeppelin</refentrytitle><manvolnum>8</manvolnum></citerefentry>
|
|
</para>
|
|
|
|
<para>
|
|
If you plan to run more than one LANE clients, LANE service or LANE
|
|
clients and LANE service, you need to specify different local ATM
|
|
addresses for each demon. Since all the LANE demons use similar
|
|
service access points (SAPs) they need different ATM addresses to
|
|
differentiate between connections.
|
|
</para>
|
|
|
|
<para>
|
|
Just as with CLIP, the LANE client consists of two parts: a demon
|
|
process called <application>zeppelin</application>
|
|
which takes care of the LANE protocol
|
|
and kernel part which contains LANE ARP cache.
|
|
</para>
|
|
|
|
<para>
|
|
<application>atmsigd</application> and <application>ilmid</application>
|
|
must already be running when
|
|
<application>zeppelin</application> is started. When
|
|
<application>zeppelin</application> starts, the kernel
|
|
creates a new interface which can then be configured:
|
|
|
|
<informalexample><screen>
|
|
# zeppelin <replaceable>possibly_more_options</replaceable> &
|
|
# ifconfig lec0 <replaceable>local_address</replaceable> <replaceable>possibly_more_options</replaceable> up
|
|
</screen></informalexample>
|
|
</para>
|
|
|
|
<para>
|
|
In the example below, two LANE clients are started. The first client
|
|
uses default interface <interface>lec0</interface>,
|
|
default listen address and tries to
|
|
join the default ELAN. The other LANE client gets interface
|
|
<interface>lec2</interface>
|
|
assigned to it, binds to local address
|
|
<parameter class=command>mybox3</parameter>, tries to join
|
|
ELAN called <parameter class=command>myelan</parameter>
|
|
and will bridge packets between ELAN and
|
|
Ethernet segments. Address <parameter class=command>mybox3</parameter>
|
|
is defined in
|
|
<filename>/etc/hosts.atm</filename>. Rest of the bridging can be configured
|
|
by reading the Bridging mini-HOWTO. [<xref linkend="bridge-howto">]
|
|
|
|
<informalexample><screen>
|
|
# zeppelin &
|
|
# ifconfig lec0 10.1.1.42 netmask 255.255.255.0 \
|
|
broadcast 10.1.1.255 up
|
|
#
|
|
# zeppelin -i 2 -l mybox3 -n myelan -p &
|
|
# ifconfig lec2 10.1.2.42 netmask 255.255.255.0 \
|
|
broadcast 10.1.2.255 up
|
|
</screen></informalexample>
|
|
</para>
|
|
|
|
<para>
|
|
By default, <application>zeppelin</application> uses interface
|
|
<interface>lec0</interface>, binds to local
|
|
ATM address using selector byte value 0, tries to contact LECS using
|
|
Well-Known LECS address, joins the default ELAN as defined by the
|
|
LECS, accepts the MTU size as defined by the LES and will not act as
|
|
an proxy LEC. These parameters can be tailored with command line
|
|
options which are defined in
|
|
<citerefentry><refentrytitle>zeppelin</refentrytitle><manvolnum>8</manvolnum></citerefentry>.
|
|
</para>
|
|
|
|
<para>
|
|
<application>zeppelin</application> will automatically join any ELANs
|
|
which use higher
|
|
MTU than the default MTU of 1516 bytes. The MTU of the LANE
|
|
interface will adjust itself according to the MTU of the current
|
|
ELAN.
|
|
</para>
|
|
|
|
<para>
|
|
The state of the LANE ARP cache entries can be monitored through
|
|
<filename>/proc/net/atm/lec</filename>.
|
|
For each entry the MAC and ATM addresses and status
|
|
is listed. If the entry has an active connection, the connection
|
|
identifiers are also listed.
|
|
</para>
|
|
|
|
<para>
|
|
The LANE service (
|
|
<citerefentry><refentrytitle>lecs</refentrytitle><manvolnum>8</manvolnum></citerefentry>,
|
|
<citerefentry><refentrytitle>les</refentrytitle><manvolnum>8</manvolnum></citerefentry>, and
|
|
<citerefentry><refentrytitle>bus</refentrytitle><manvolnum>8</manvolnum></citerefentry>)
|
|
is
|
|
configured using configuration files. The configuration file syntax is
|
|
listed on the respective manual pages.
|
|
</para>
|
|
|
|
<para>
|
|
A more detailed description of Linux LANE services is discussed in
|
|
Marko Kiiskilä's Master's Thesis
|
|
[<xref linkend="kiis">].
|
|
|
|
|
|
</para>
|
|
|
|
</sect2>
|
|
|
|
<sect2 id="IP-Over-ATM.MPOA">
|
|
<title id="IP-Over-ATM.MPOA.title">MPOA</title>
|
|
|
|
<para>
|
|
The Linux MPOA client continues the tradition of user space -- kernel
|
|
divided ATM services. The demon process called
|
|
<application>mpcd</application> processes
|
|
MPOA control packets while the kernel holds MPOA ingress and egress
|
|
caches and does the packet forwarding.
|
|
</para>
|
|
|
|
<para>
|
|
Man page:
|
|
<citerefentry><refentrytitle>mpcd</refentrytitle><manvolnum>8</manvolnum></citerefentry>
|
|
</para>
|
|
|
|
<para>
|
|
<application>atmsigd</application> and <application>ilmid</application>
|
|
must already be running when
|
|
<application>mpcd</application> is started.
|
|
Since MPOA detects IP layer flows from LANE
|
|
traffic, you need to have <application>zeppelin</application>
|
|
running before MPOA can
|
|
function. However, the order in which <application>zeppelin</application>
|
|
and <application>mpcd</application>
|
|
is started is not fixed. You can kill any of the demons at your will
|
|
and restart it later without need to restart the other demon. The
|
|
easiest way to disable MPOA is to kill the running
|
|
<application>mpcd</application>.
|
|
</para>
|
|
|
|
<para>
|
|
Below is the example from Section
|
|
<link linkend="IP-Over-ATM.LAN-Emulation" endterm="IP-Over-ATM.LAN-Emulation.title"></link>
|
|
which starts two LANE
|
|
clients. The configuration has been augmented with two MPOA clients
|
|
which the LANE clients will serve.
|
|
|
|
<informalexample><screen>
|
|
# zeppelin &
|
|
# ifconfig lec0 10.1.1.42 netmask 255.255.255.0 \
|
|
broadcast 10.1.1.255 up
|
|
# mpcd -s mybox1 -l mybox2 &
|
|
#
|
|
# zeppelin -i 2 -l mybox3 -n myelan -p &
|
|
# ifconfig lec2 10.1.2.42 netmask 255.255.255.0 \
|
|
broadcast 10.1.2.255 up
|
|
# mpcd -i 2 -s mybox4 -l mybox5 &
|
|
</screen></informalexample>
|
|
</para>
|
|
|
|
<para>
|
|
The MPOA demon needs two different local ATM addresses which it uses
|
|
when initiating and receiving data and control connections. The
|
|
addresses can be the same as with e.g.
|
|
<application>zeppelin</application> but must be
|
|
different among other <application>mpcd</application> demons. By default,
|
|
<application>mpcd</application> does
|
|
not retrieve configuration information from the LECS. The necessary
|
|
command line options and an example of using LECS are shown on the
|
|
<application>mpcd</application> manual page.
|
|
The manual page also lists the rest of the available options.
|
|
</para>
|
|
|
|
<para>
|
|
The contents of MPOA ingress and egress caches can be monitored
|
|
through the <filename>/proc/net/atm/mpc</filename> file.
|
|
</para>
|
|
|
|
<para>
|
|
The Linux MPOA client also supports CBR traffic class for shortcuts
|
|
SVCs instead of default UBR. The QoS specifications for future
|
|
shortcuts can be set and modified using
|
|
<filename>/proc/net/atm/mpc</filename>.
|
|
|
|
<informalexample><screen>
|
|
# echo add 130.230.54.146 tx=80000,1600 rx=tx > /proc/net/atm/mpc
|
|
# # generate enough traffic to trigger a shortcut
|
|
# cat /proc/net/atm/mpc
|
|
QoS entries for shortcuts:
|
|
IP address
|
|
TX:max_pcr pcr min_pcr max_cdv max_sdu
|
|
RX:max_pcr pcr min_pcr max_cdv max_sdu
|
|
130.230.54.146
|
|
80000 0 0 0 1600
|
|
80000 0 0 0 1600
|
|
|
|
Interface 2:
|
|
|
|
Ingress Entries:
|
|
IP address State Holding time Packets fwded VPI VCI
|
|
130.230.4.3 invalid 1160 0
|
|
130.230.54.146 resolved 542 151 0 109
|
|
...
|
|
</screen></informalexample>
|
|
|
|
The shortcut to IP address <parameter class=command>130.230.54.146</parameter>
|
|
was established with
|
|
the parameters shown above. There also exist patches which extend the
|
|
flow detection to fully support layer 4 flows. The layer 4 flows are
|
|
expressed as a 5 tuple (proto, local addr, local port, remote addr,
|
|
remote port) and they identify application to application flows. If
|
|
you are interested, see
|
|
<ulink url="ftp://sunsite.tut.fi/pub/Local/linux-atm/mpoa/">ftp://sunsite.tut.fi/pub/Local/linux-atm/mpoa/</ulink>
|
|
for the latest
|
|
patch.
|
|
</para>
|
|
|
|
</sect2>
|
|
|
|
</sect1>
|
|
|
|
<bibliography id="Bibliography">
|
|
<title id="Bibliography.title">Bibliography</title>
|
|
|
|
<bibliodiv>
|
|
<title>References</title>
|
|
|
|
<biblioentry id="api" xreflabel="api">
|
|
<title>Linux ATM API</title>
|
|
<author>
|
|
<firstname>Werner</firstname>
|
|
<surname>Almesberger</surname>
|
|
</author>
|
|
<releaseinfo>
|
|
<ulink url="http://linux-atm.sourceforge.net/API/">http://linux-atm.sourceforge.net/API/</ulink>
|
|
</releaseinfo>
|
|
<pubdate>July 1996</pubdate>
|
|
</biblioentry>
|
|
|
|
<biblioentry id="RFC1577" xreflabel="RFC1577">
|
|
<title>Classical IP and ARP over ATM (RFC1577)</title>
|
|
<author>
|
|
<firstname>Mark</firstname>
|
|
<surname>Laubach</surname>
|
|
</author>
|
|
<pubdate>January 1994</pubdate>
|
|
</biblioentry>
|
|
|
|
<biblioentry id="lanev1" xreflabel="lanev1">
|
|
<title>LAN Emulation Over ATM -- Version 1.0</title>
|
|
<corpauthor>ATM Forum</corpauthor>
|
|
<pubdate>February 1996</pubdate>
|
|
</biblioentry>
|
|
|
|
<biblioentry id="lanev2" xreflabel="lanev2">
|
|
<title>LAN Emulation Over ATM -- Version 2 -- LUNI Specification</title>
|
|
<corpauthor>ATM Forum</corpauthor>
|
|
<pubdate>July 1997</pubdate>
|
|
</biblioentry>
|
|
|
|
<biblioentry id="mpoav1" xreflabel="mpoav1">
|
|
<title>Multi-Protocol Over ATM -- Version 1.0</title>
|
|
<corpauthor>ATM Forum</corpauthor>
|
|
<pubdate>July 1997</pubdate>
|
|
</biblioentry>
|
|
|
|
<biblioentry id="bridge-howto" xreflabel="bridge-howto">
|
|
<title>Bridging mini-Howto</title>
|
|
<author>
|
|
<firstname>Christopher</firstname>
|
|
<surname>Cole</surname>
|
|
</author>
|
|
<releaseinfo>
|
|
<ulink url="http://www.linuxdoc.org/HOWTO/mini/Bridge.html">http://www.linuxdoc.org/HOWTO/mini/Bridge.html</ulink>
|
|
</releaseinfo>
|
|
<pubdate>March, 2001</pubdate>
|
|
</biblioentry>
|
|
|
|
<biblioentry id="kiis" xreflabel="kiis">
|
|
<title>Implementation of LAN Emulation Over ATM in Linux</title>
|
|
<author>
|
|
<firstname>Marko</firstname>
|
|
<surname>Kiiskilä</surname>
|
|
</author>
|
|
<releaseinfo>
|
|
<ulink url="ftp://sunsite.tut.fi/pub/Local/linux-atm/misc/">ftp://sunsite.tut.fi/pub/Local/linux-atm/misc/</ulink>
|
|
</releaseinfo>
|
|
<pubdate>October 1996</pubdate>
|
|
</biblioentry>
|
|
|
|
</bibliodiv>
|
|
|
|
</bibliography>
|
|
|
|
</article>
|
|
|