@ -26,6 +26,14 @@
|
||||||
</authorgroup>
|
</authorgroup>
|
||||||
|
|
||||||
<revhistory>
|
<revhistory>
|
||||||
|
<revision>
|
||||||
|
<revnumber>2.2</revnumber>
|
||||||
|
<date>2007-05-22</date>
|
||||||
|
<authorinitials>esr</authorinitials>
|
||||||
|
<revremark>
|
||||||
|
Minor update with more info about battery types.
|
||||||
|
</revremark>
|
||||||
|
</revision>
|
||||||
<revision>
|
<revision>
|
||||||
<revnumber>2.1</revnumber>
|
<revnumber>2.1</revnumber>
|
||||||
<date>2005-09-28</date>
|
<date>2005-09-28</date>
|
||||||
|
@ -101,7 +109,7 @@ yourself.</para>
|
||||||
|
|
||||||
<para>The advice in this document is aimed primarily at small
|
<para>The advice in this document is aimed primarily at small
|
||||||
installations — one computer and one UPS. Thus we'll focus on
|
installations — one computer and one UPS. Thus we'll focus on
|
||||||
consumer-grade UPes, especially those designed for home and
|
consumer-grade UPSes, especially those designed for home and
|
||||||
small-business use. If you are a data center administrator running a
|
small-business use. If you are a data center administrator running a
|
||||||
big server farm, there is a whole different (and much more expensive)
|
big server farm, there is a whole different (and much more expensive)
|
||||||
range of technologies we'll do no more than hint at here.</para>
|
range of technologies we'll do no more than hint at here.</para>
|
||||||
|
@ -164,7 +172,7 @@ fractions of a second to hours. This can be caused by heavy equipment coming on
|
||||||
line such as shop tools, elevators, compressors etc. Also occurs when
|
line such as shop tools, elevators, compressors etc. Also occurs when
|
||||||
utility companies deliberately do this to cope with peak load times.</para>
|
utility companies deliberately do this to cope with peak load times.</para>
|
||||||
|
|
||||||
<para>A <emphasis>spike</emphasis> is a remendous increase in voltage over
|
<para>A <emphasis>spike</emphasis> is a tremendous increase in voltage over
|
||||||
a very short period of time often caused by a direct lightning strike on a
|
a very short period of time often caused by a direct lightning strike on a
|
||||||
power line or when power returns after a blackout.</para>
|
power line or when power returns after a blackout.</para>
|
||||||
|
|
||||||
|
@ -470,13 +478,12 @@ that. Running unprotected is false economy, because you
|
||||||
and, Murphy's Law being what it is, you will always get hit at the
|
and, Murphy's Law being what it is, you will always get hit at the
|
||||||
worst possible time.</para>
|
worst possible time.</para>
|
||||||
|
|
||||||
<para>One thing to note is that you typically shouldn't put a
|
<para>One thing to note is that you typically shouldn't put a laser printer
|
||||||
laser printer on a UPS — toner heaters draw enough current to
|
on the brownout-protected sockets in a UPS — toner heaters draw
|
||||||
overload a UPS and cause a shutdown within seconds. The other thing
|
enough current to overload a UPS and cause a shutdown within
|
||||||
is that you can't even put the laser printer on the same circuit with
|
seconds. Modern UPSes generally have some plugs that are marked
|
||||||
a UPS — the heater kicks on every 20-30 seconds, and most UPSs
|
surge-suppressed but not filtered through the battery; plug your
|
||||||
will see the current draw as a brownout. So buy a separate line
|
printer into one of those.</para>
|
||||||
conditioner for the laser printer.</para>
|
|
||||||
|
|
||||||
<para>A UPS should be wired directly to (or plugged directly into) the
|
<para>A UPS should be wired directly to (or plugged directly into) the
|
||||||
AC supply (i.e. a surge suppressor is neither required nor suggested
|
AC supply (i.e. a surge suppressor is neither required nor suggested
|
||||||
|
@ -523,11 +530,11 @@ American Power Corporation.</para>
|
||||||
|
|
||||||
<para>Both are solid, well-run projects. Their development groups are
|
<para>Both are solid, well-run projects. Their development groups are
|
||||||
mutually friendly, and there has been occasional talk of a merger.
|
mutually friendly, and there has been occasional talk of a merger.
|
||||||
Awkwardly, as of October 2003 the <application>apcupsd</application>
|
Awkwardly, the <application>apcupsd</application> project is in many ways
|
||||||
project is the more featureful of the two, with, among other things,
|
the more featureful of the two, with, among other things, better USB
|
||||||
better USB support and better documentation — but the NUT tools
|
support and better documentation — but the NUT tools have a cleaner
|
||||||
have a cleaner architecture, more developers, and acceptance in Red Hat
|
architecture, more developers, and acceptance in Red Hat and other major
|
||||||
and other major distributions.</para>
|
distributions.</para>
|
||||||
|
|
||||||
<para>My advice is simple; run <application>apcupsd</application> if
|
<para>My advice is simple; run <application>apcupsd</application> if
|
||||||
you buy an APC UPS, and the NUT tools if you buy anything else. RPMs
|
you buy an APC UPS, and the NUT tools if you buy anything else. RPMs
|
||||||
|
@ -688,6 +695,18 @@ do this for you. If not, your local garbage company or waste-disposal
|
||||||
authority can explain to you how and where to turn them in
|
authority can explain to you how and where to turn them in
|
||||||
safely.</para>
|
safely.</para>
|
||||||
|
|
||||||
|
<para>Many UPS models use gel-cel batteries in standard formats like 12.0
|
||||||
|
V, 7.2Ah (151x64x94 mm). Warning: Many manufactors sell two or three
|
||||||
|
different types: standard use, cyclic use and high-current use. UPSes
|
||||||
|
require high-current and some UPS don't work well with batteries for
|
||||||
|
standard use, because the voltage goes low too early under high load (the
|
||||||
|
UPS turns off too fast or the output voltage drops so that the computer
|
||||||
|
turns off). Standard batteries are for alarm devices, emergency lights or
|
||||||
|
things like that. For instance Panasonic sells the "LCR127R2PG1"
|
||||||
|
(standard), and "UPRW1245P1" (high current), Fiamm the "FG20271" (standard)
|
||||||
|
and "FGH20902" (high current), CSB the "GP1272" (standard) and "HR 1234W"
|
||||||
|
(high current).</para>
|
||||||
|
|
||||||
<para>Below, you will find some suggestions for buying replacement
|
<para>Below, you will find some suggestions for buying replacement
|
||||||
batteries. One <emphasis>important</emphasis> note of caution: at
|
batteries. One <emphasis>important</emphasis> note of caution: at
|
||||||
least one user purchased one of the aftermarket batteries noted below
|
least one user purchased one of the aftermarket batteries noted below
|
||||||
|
|
Loading…